61. A 20KVA single phase 960-120V transformer with Z% = 4.8%. Find the maximum short circuit current for the secondary.
Q: INVESTIGATE the CT ratio and spill current setting of differential protection of transformer for the…
A: Transformer is delta star 36/16 kV 11 MVA CT secondary current=1A
Q: A 2.5 kVA, 200v/40V single-phase transformer has the primary resistance and reactance of 3 and 12 0,…
A: The transformer has a primary and a secondary side. It converts electrical power to electrical power…
Q: 10-KVA, 2400/240 V, single-phase transformer has a secondary equivalent impedance of (0.06 + 10.30)…
A:
Q: A transformer has 800 primary turns and 100 secondary turns. The primary and secondary resistances…
A: Transformer: Transformer is a static electrical device which transfers power from one circuit to…
Q: Example 33.7. A 5,000-kVA, 3-phase transformer, 6.6/33-kV, NY, has a no-load loss of and a full-load…
A: In this question , we will find primary voltage for given load of 3 phase transformer....
Q: Problem 17. A 200KVA rated transformer has a full-load copper loss of 1.5 kW and an iron loss of 1…
A: Performance indices of transformer The performance of the transformer can be measured by the…
Q: A balance 3-phase transformer bank has delta-connected primary and wye-connected secondary windings.…
A:
Q: When the two-phase load at the secondary has a 0.9 p.f, the main transformer operates at 77.9% p.f…
A: In some industries , 2-phase supply system is required for operating certain loads such as Electric…
Q: A 5 kVA single-phase transformer has a turns ratio of 10:1 and is fed from a 2.5 kV supply.…
A:
Q: A simple distribution system having one of the feeders supplies an industrial load with a peak of 4…
A: Diversity Factor = (Sum of Individual Maximum Demands / Maximum Demand of the System.) Load…
Q: A transformer has an input voltage of 2kV and a step-down ratio of 5:1. The primary and secondary…
A: According to question: The equivalent resistance with respect to secondary winding is calculated as…
Q: A 2.5 kVA, 200v/40V single-phase transformer has the primary resistance and reactance of 3 and 12 0,…
A: Answer
Q: A 500 kVA, 7200- 240 V, 60 Hz transformer with a 2.2% impedance was severely damaged as a result of…
A: we need to determine short circuit current in kA. percent impedance in p.u. for 60 kA short circuit…
Q: (b) Mr. Musa Al Biruni is analyzing a 100 kVA, 60 Hz, 7200-48ov, single phase transformer, which has…
A: Given 100KVA, 60Hz, 7200/480V, single phase transformer. And the following parameters expressed in…
Q: 7- A 5KVA, 220/110V, 50HZ 1-phase transformer has Reg1 and Xeg1 of 0.9680 and 1.9630 respectively.…
A:
Q: In which of the following transformer, the secondary winding is always short circuited by ammeter?…
A: In this question we need to choose a correct option.
Q: Problem 6.10: A 2-MVA, 4160/480 V transformer has series impedance of R= 2% and X = 6%. Determine…
A: The solution can be achieved as follows.
Q: The appropriate DB for 1000KVA transformer is?
A: We are all very aware of the sound produces by practical transformer. It can be humming sound,…
Q: An Auto-transformer is a type of circuit used to derive two-phase power from a three- phase source…
A: This problem is based on the Auto transformer, It's is type of circuit used to derive two phase…
Q: 3. A balanced 3 phase load of 50 KVA, 220 volts at 0.8 lagging power factor is supplied by an open…
A:
Q: 5 Determine the regulation of an 8kVA, 100 V/ 200 V, single phase transformer when its secondary…
A: Given values are - E1E2=100200S=8kVAV2=194Volt
Q: A single phase 100KVA 4000/240V 60 Hz. transformer, whose impedance refered to low voltage side is…
A: Transformer is a static electrical device which transfers power from one circuit to another circuit…
Q: A 2.5 kVA, 200V/40V single-phase transformer has the primary resistance and reactance of 3 and 12 0,…
A: “Since you have asked multiple question, we will solve the first question for you. If you want any…
Q: power system comprises of a steam-turbine generator feeding a 161kV transmission line through a…
A:
Q: A 402 kVA single phase transformer has an efficiency of 96.4%, when delivering full load at 0.9…
A: Solve as below
Q: Single phase transformer has 24KVA, 2400/240, 50 Hz. Its series impedance Z, 0.15+j0.6pu connected t…
A:
Q: A 70 KVA,3-ph,delta/star,50Hz transformer, has number of turns of primary and secondary 660 and 80…
A: Given Pi = 70 KVA, N1 = 660, N2 = 80, primary current = 12 A, power factor = 0.95 Calculating…
Q: 1. Aring core current transformer of ration 1000/5 A is operating at full primary current with the…
A: As per Bartleby guidelines we are allowed to solve only one question, as these questions under…
Q: 2. How to solve electric circuit analysis using transform method (series circuit analysis & parallel…
A:
Q: Find the value of line current and phase current of primary and secondary of a 100 kVA 2200/440 V, 3…
A:
Q: A 10 KVA, 400 V/200 V single phase transformer with 10% impedance, draws s steady short circuit…
A: Given: A 400 V/200 V single phase transformer with, Power rating, S = 10 kVA Impedance percentage,…
Q: The impedance of the primary windings of a single-phase transformer with a transformation ratio of 6…
A:
Q: C2 (i). Draw the transfer characteristics and explain the working of differential transformer and…
A: As per our policy we can provide solution for first question only The differential transformer :…
Q: A 2.5 kVA, 200V/40v single-phase transformer has the primary resistance and reactance of 3 and 12 0,…
A: The transformer has a primary and a secondary side. It converts electrical power to electrical power…
Q: A 5KVA, 120/540V single phase transformer has a secondary terminal voltage of 500 V when loaded.…
A: Given: Q=5 kVAVLV=120 VVHV=540 VVL=500 V
Q: The leakage reactance of a 66 kV / 11 kV oil-cooled power transformer with 40 MVA power value is 8%…
A: In this question we need to find a pu value of reactance at 100 MVA base power, base impedance and…
Q: A single-phase step-down transformer is rated at 15 kVA, 440V/120 V. Compute the rated current of…
A: Given Data: Rating of transformer = 15 kVA Primary voltage = 440 V secondary voltage = 120 V
Q: Show the connection diagram of CTs and the relay for the differential protection of a 132/33 kV, Y-∆…
A: The current Transformer is an electrical device that steps down the current into a measuring range.…
Q: 1- Determine the magnitude of the series impedance parameters of Transformer(Req,Xeq) referred to…
A:
Q: A transformer has 800 primary turns and 250 secondary turns. The primary and secondary resistances…
A:
Q: short circuit test of a single phase transformer, the ammeter gives us rated current. Select one:…
A: We need to tell about the given statement is true or false
Q: A 2.5 kVA, 200V/40V single-phase transformer has the primary resistance and reactance of 3 and 12 0,…
A: The transformer has a primary and a secondary side. It converts electrical power to electrical power…
Q: The leakage reactance of a 66 kV / 11 kV oil-cooled power transformer with 40 MVA power value is 8%…
A:
Q: 6. A 5,000-kVA, 3-phase transformer, 6.6/33-kV, NY, has a no-load loss of 15 kV and a full-load loss…
A: In this question 3 phase transformer delta -star is given....We have to find out primary voltage…
Q: 33 A 5 kVA single-phase transformer has a turns ratio of 10:1 and is fed from a 2.5 kV supply.…
A: (33) A 5 kVA single phase transformer has, Turns ratio = 10 : 1 Supply voltage ( primary voltage)…
Q: The input current to a 3-phase step down transformer connected to a 16 KV supply system is 29 A.…
A:
Q: A 100 kVA, 7,200/480V., 60Hz single-phase transformer has the primary and secondary resistances of…
A:
Q: A 10 KVA, single phase transformer has a trunks ratio of 12:1 and is supplied from a 2.4 KV supply.…
A:
Q: A 12 kVA, single-phase transformer has a turns ratio of 14:1 and is supplied from a 2.34 kV supply.…
A:
Q: 2) The following no-load results are obtained at the excitation branch of a 10, 20 kVA Hz…
A:
Trending now
This is a popular solution!
Step by step
Solved in 3 steps with 4 images
- An infinite bus, which is a constant voltage source, is connected to the primary of the three-winding transformer of Problem 3.53. A 7.5-MVA,13.2-kV synchronous motor with a sub transient reactance of 0.2 per unit is connected to the transformer secondary. A5-MW,2.3-kV three-phase resistive load is connected to the tertiary Choosing a base of 66 kV and 15 MVA in the primary, draw the impedance diagram of the system showing per-unit impedances. Neglect transformer exciting current, phase shifts, and all resistances except the resistive load.(a) An ideal single-phase two-winding transformer with turns ratio at=N1/N2 is connected with a series impedance Z2 across winding 2. If one wants to replace Z2, with a series impedance Z1 across winding 1 and keep the terminal behavior of the two circuits to be identical, find Z1 in terms of Z2. (b) Would the above result be true if instead of a series impedance there is a shunt impedance? (c) Can one refer a ladder network on the secondary (2) side to the primary (1) side simply by multiplying every impedance byat2 ?For an ideal 2-winding transformer, an impedance Z2 connected across winding 2 (secondary) is referred to winding 1 (primary) by multiplying Z2 by (a) The turns ratio (N1/N2) (b) The square of the turns ratio (N1/N2)2 (c) The cubed turns ratio (N1/N2)3
- The motors M1andM2 of Problem 3.45 have inputs of 120 and 60 MW, respectively, at 13.2 kV, and both operate at unity power factor. Determine the generator terminal voltage and voltage regulation of the line. Neglect transformer phase shifts.In order to avoid difficulties with third-harmonic exciting current, which three-phase transformer connection is seldom used for step-up transformers between a generator and a transmission line in power systems. (a) Y- (b) -Y (c) Y-YA single-phase, 50kVA, 2400:240V distribution transformer has an impedance of 0.72+j0.92Ω from the high voltage winding and 0.007+j0.009Ω from the low voltage winding. This transformer is supplied by a feeder whose impedance is 0.3+j1.6Ω. Determine the voltage at the emitter terminal of the feeder when the load connected to the transformer secondary draws rated current at 240V with 0.8 lagging power factor. For this case, it is convenient to use the approximate circuit of the transformer given below. PLEASE, TYPE, HAND WRITING GETS UNDERSTANDING,
- A 70 KVA,3-ph,delta/star,50Hz transformer, has number of turns of primary andsecondary 660 and 80 turns respectively. The transformer draws 12 A from the main source, and secondary has a balanced Load at 0.95 Lagging p.f.. Determine the secondary phasevoltage, line current and output.For the 11000/400V, Δ/Y 3-ph transformer, if the line current in the secondary is 500A calculate the line and phase current in the primary.A single-phase step-down transformer is rated at 15 kVA, 440V/120 V. Compute the rated current of the secondary winding in Amps.
- Find the value of line current and phase current of primary and secondary of a 100 kVA 2200/440 V, 3 phase delta-star transformer.The appropriate DB for 1000KVA transformer is?Draw the complete phasor diagram of a practical single-phase transformer supplying RL load. Assume transformation ratio of unity.