A 200 km, 3-phase transmission line has its conductors placed at the corners of an equilateral triangle of 2-5 m side. The radius of each conductor is 1 cm. Calculate: Inductive reactance of aline
Q: 7. A 3-phase line conductor 3/5 cm in diameter spaced equilaterally 1.5 m apart. If the dielectric…
A: Given data diameter = 3/5 cm spacing = 1.5 m dielectric strength = 30 kV
Q: Q: The Fig. below shows the arrangement of a double circuit single phase line. Conductors (a, b, and…
A:
Q: A three phase 60HZ, 85kV transmission line consisting of 3 conductors are placed at the comers of a…
A: As per Bartleby guidelines we are allowed to solve only three subparts, please ask the rest again.
Q: Taking the dielectric strength of air to be 30 kV/cm, calculate the disruptive critical voltage for…
A: Critical disruptive voltage, vc=g0r logedrwhere g0=breakdown strength of air d=distance between…
Q: 3. Calculate the capacitance of a 3-phase transmission line equilaterally spaced at 6m if conductor…
A:
Q: 3-phase, 220kV, 200km overhead transmission line has its conductors on the corners of triangle with…
A: In this question we need to find a total inductance and capacitance of transmission line.
Q: Example 9.6. Two conductors of a single phase line, each of 1 cm diameter, are arranged in a…
A: Self GMD =(0.7788 x r)2 x D4 = (0.7788 x 0.5)2 x 10024 = 6.2401…
Q: Q3: A single circuit three-phase transmission line is composed of four ACSR conductors per phase…
A:
Q: Q4: Each conductor of a 3-phase high-voltage transmission line is suspended by a string of 4…
A: Given data, V2=13.2 KV, V3=18 KVXc= 1Ω
Q: A 3-phase transmission line consists of 2 cm radius conductors spaced symmetrically 3 metres apart,…
A:
Q: 1.A single phase transmission line has two parallel conductors 1-5 metres apart, the diameter of…
A: The space between two parallel conductors are:
Q: three phase 60Hz, 120kV transmission line consisting of 3 conductors are placed at the corners of a…
A: As per Bartleby guidelines we are allowed to solve only three subparts, please ask the rest again.
Q: b) Figure 2 shows the configuration of a single-phase two-conductor in the transmission line.…
A: Since you have asked multiple questions so we will solve the 2nd question for you. If you want any…
Q: 2. A single phase transmission line has two parallel conductors 2.5 m apart, the radius of each…
A: Solution of given Q is showing in step 2
Q: 1. A single-phase transmission line is composed of two solid round conductors having a radius of…
A: Given: Single phase transmission Radius of conductor, r=.45 cm Distance between conductors, d=350 cm
Q: A 3-phase, 60 Hz, 345 kV overhead transmission line has conductors placed in a specific manner as…
A:
Q: A three-phase 60Hz transposed transmission line has a flat horizontal spacing configuration. The…
A: A three-phase 60Hz flat horizontal spacing configuration. The line reactance is 0.486 ohm per km…
Q: Example 9.2. A single phase transmission line has two parallel conductors 3 m apart, the ra- dius of…
A: In this question we need to find a loop inductance of transmission line if material is copper and…
Q: The inductive reactance of the line conductor is 64 Ω per km, then the inductance of the conductor…
A:
Q: (a) Conductors of a 3-phase line are arranged at the corners of a triangle of sides 15, 15, and 18…
A:
Q: A three-phase (50HZ) transmission line with symmetrically spaced (equilateral triangle form) between…
A: In this answer we will find the capacitance and thereby calculate the capacitive reactance as shown…
Q: 2. Solve the following question and submit the solution before the deadline. Calculate the…
A:
Q: A 3-phase transmission line using 20 mm diameter conductor. When these conductors are placed at the…
A: As per the guidelines of Bartleby we supposed to answer first question for remaining questions we…
Q: three phase 60Hz, 120kV transmission line consisting of 3 conductors are placed at the corners of a…
A:
Q: 4. A double-circuit, single-phase transmission line is shown below. Find the inductance per meter of…
A:
Q: 4. A 3-phase bundled transmission line of 200 km length consists of three ACSR conductors as shown |…
A:
Q: The 130 km long three phase 50HZ, 95kV transmission line consisting of 3 conductors are placed at…
A:
Q: a single-phase transmission line has two parallel conductors, 1.5 meters apart. the radius of each…
A: According to question: Let A and B be two conductor of single phase transmission line, so inductance…
Q: A 200 km, 3-phase transmission line has its conductors placed at the corners of an equilateral…
A:
Q: A three phase 60HZ, 85kV transmission line consisting of 3 conductors are placed at the comers of a…
A: As per the guidelines of Bartleby we supposed to answer first three subparts of the question for…
Q: The inductive reactance of the line conductor is 67 2 per km, then the inductance of the conductor…
A:
Q: A 3-phase, 60 Hz, 345 kV overhead transmission line has conductors placed in a specific manner as…
A:
Q: A three phase transmission line has conductors arranged in the corners of an equilateral triangle of…
A: Inductance per phase for three phase is given Spacing between condcutors D=0.03 radius=1.5…
Q: A single-phase transmission line is composed of two solid round conductors having a radius of 0.45cm…
A: In this question we will find inductance per conductor and inductance of single phase transmission…
Q: In a 10 km long three phase line the diameter of the conductor is 25 mm hence the conductors are…
A:
Q: Taking the dielectric strength of air to be 30 kV / cm, calculate the disruptive critical voltage…
A: Given Dielectric strength of air and radius of conductor.we need to determine the disruptive…
Q: A 3-phase, 220 kV, 50 Hz transmission line consists of 1·2 cm radius conductors spaced 2 m at the…
A: Given, The radius of conductor (r) = 1.2cm Temperature(t) = 20oC The barometric pressure(b) = 72·2…
Q: A single-phase transmission line has two parallel conductors 3.2 meters apart, radius of each…
A:
Q: 1. A Single-phase, two-wire overhead line has solid cylindrical copper conductors with 2.4 cm…
A:
Q: A 3-phase line has conductors 6 cm in diameter spaced equilaterally 3 m apart. If the dielectric…
A:
Q: The capacitance between the line to neutral of a three-phase 50 Hz, 66KV overhead line conductors…
A: Capacitance between line to neutral C= 8.5×10-7 F/ph/m Frequency f= 50Hz Reactance Xc ?
Q: A 3-phase overhead transmission line has its coductors arranged at the cor- ners of an equilateral…
A:
Q: : A single circuit three-phase transmission line is composed of four ACSR conductors per phase with…
A:
Q: 4. A 3-phase overhead transmission line has its conductors arranged at the corners of an equilateral…
A: In this question , we will find capacitance of line per km..
Q: Q3: A single circuit three-phase transmission line is composed of four ACSR conductors per phase…
A: Geometric mean radius of the system is calculated as GMRsystem=GMRa*GMRb*GMRc3 Geometric mean radius…
Q: A 3-phase transmission line 100 km long has its conductors of 0.5 cm diameter spaced at the corners…
A: Calculate the radius of the conductors. r=0.5 cm2=0.25 cm
Q: 1/Find the Inductance in Henry per meter of a Three-Phase Transmission Line using 1.24 cm diameter…
A: In this answer let us try to find the inductance of a three phase transmission line with equilateral…
Find only a part
Step by step
Solved in 3 steps with 5 images
- A 60-Hz, single-phase two-wire overhead line has solid cylindrical copper conductors with a 1.5 cm diameter. The conductors are arranged in a horizontal configuration with 0.5 m spacing. Calculate in mH/km (a) the inductance of each conductor due to internal flux linkages only, (b) the inductance of each conductor due to both internal and external flux linkages, and (c) the total inductance of the line.Find the inductive reactance per mile of a single-phase overhead transmission line operating at 60 Hz given the conductors to be Partridge and the spacing between centers to be 30 ft.If the per-phase line loss in a 70-km-long transmission line is not to exceed 65 kW while it is delivering 100 A per phase, compute the required conductor diameter if the resistivity of the conductor material is 1.72108-m.
- In terms of line-to-line capacitance, the line-to-neutral capacitance of a single-phase transmission line is Same Twice One-halfCalculate the capacitance-to-neutral in F/m and the admittance-to-neutral in S/km for the three-phase line in Problem 4.18. Also calculate the line-charging current in kA/phase if the line is 110 km in length and is operated at 230 kV. Neglect the effect of the earth plane.Calculate the inductive reactance in /km of a bundled 500-kV, 60-Hz, three-phase completely transposed overhead line having three ACSR 1 113 kcmil conductors per bundle, with 0.5 m between conductors in the bundle. The horizontal phase spacings between bundle centers are 10, 10, and 20 m.
- A 40-km, 220-kV, 60-Hz, three-phase overhead transmission line has a per-phase resistance of 0.15/km, a per-phase inductance of 1.3263 mH/km, and negligible shunt capacitance. Using the short line model, find the sending-end voltage, voltage regulation, sending-end power, and transmission line efficiency when the line is supplying a three-phase load of (a) 381 MVA at 0.8 power factor lagging and at 220 kV and (b) 381 MVA at 0.8 power factor leading and at 220 kV.A single phase transmission line has two parallel conductors 6 m apart, the ra dius of each conductor being 2 cm. Calculate the loop inductance per km length of the line if the material of the conductor is (i) copper (ii) steel with relative permeability of 7.A 200 km, 3-phase transmission line has its conductors placed at the corners of an equilateral triangle of 2·5 m side. The radius of each conductor is 1 cm. Calculate : Inductive reactance of aline line to neutral capacitance of the line charging current per phase if the line is maintained at 66 kV, 50 Hz.
- A single-phase transmission line is composed of two solid round conductors having aradius of 0.45cm each. If the conductors are spaced 3.5m, calculatea. the value of the inductance per conductorb. the inductance of the lineA single-phase transmission line consisting of two conductors, the radius of each conductor is 0.4 cm, the distance between the conductors is three and half meters and the height above ground is eight meter. Determine 1)The capacitance in uF/km without effect of ground 2)The capacitance in uF/km with effect of groundA 3-phase transmission line 100 km long has its conductors of 0.5 cm diameter spaced at the corners of the equilateral triangle of 120 cm side. Find the inductance per phase of the system