A. A student establishes the time constant of a temperature sensor by first holding it immersed in hot water and then suddenly removing it and holding it immersed in cold water. Several other students perform the same test with similar sensors. Overall, their results are inconsistent, with estimated time constants differing by as much as a factor of 1.2. Offer suggestions about why this might happen. Hint: Try this yourself and think about control of test conditions. B. Which would you expect to be better suited to measure a time-dependent temperature, a thermal sensor (e.g., a thermocouple) having a small diameter spherical bead or one having a large diameter spherical bead? Why?

Principles of Heat Transfer (Activate Learning with these NEW titles from Engineering!)
8th Edition
ISBN:9781305387102
Author:Kreith, Frank; Manglik, Raj M.
Publisher:Kreith, Frank; Manglik, Raj M.
Chapter1: Basic Modes Of Heat Transfer
Section: Chapter Questions
Problem 1.2DP
icon
Related questions
Question
A. A student establishes the time constant of a temperature sensor by first holding it immersed in hot water and then
suddenly removing it and holding it immersed in cold water. Several other students perform the same test with
similar sensors. Overall, their results are inconsistent, with estimated time constants differing by as much as a
factor of 1.2. Offer suggestions about why this might happen. Hint: Try this yourself and think about control of
test conditions.
B. Which would you expect to be better suited to measure a time-dependent temperature, a thermal sensor (e.g., a
thermocouple) having a small diameter spherical bead or one having a large diameter spherical bead? Why?
Transcribed Image Text:A. A student establishes the time constant of a temperature sensor by first holding it immersed in hot water and then suddenly removing it and holding it immersed in cold water. Several other students perform the same test with similar sensors. Overall, their results are inconsistent, with estimated time constants differing by as much as a factor of 1.2. Offer suggestions about why this might happen. Hint: Try this yourself and think about control of test conditions. B. Which would you expect to be better suited to measure a time-dependent temperature, a thermal sensor (e.g., a thermocouple) having a small diameter spherical bead or one having a large diameter spherical bead? Why?
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
Thermodynamics of Reactive System
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Principles of Heat Transfer (Activate Learning wi…
Principles of Heat Transfer (Activate Learning wi…
Mechanical Engineering
ISBN:
9781305387102
Author:
Kreith, Frank; Manglik, Raj M.
Publisher:
Cengage Learning