Q: ENVIRONMENTAL ENGINEERING-WATER POLLUTION: Incoming wastewater, with BOD5 equal to 200mg/L, is…
A: We have been given the following informationBOD5 of incoming wastewater = 200mg/L.Initial DO is…
Q: particles, (ii) a biological process for removal of dissolved organic matter and fine suspended…
A: the waste-water treatment process consists of various processes such as screening grit removal…
Q: A given quantity of a residual discharged at one time and place can be a pollutant; if it is dis…
A: Any solid, liquid, or gaseous substance (including noise) existing in such concentrations in the…
Q: Environmental Engineering The air quality standard for ozone (O3) is 80 ppbv. Express that standard…
A: The air quality standard for ozone is 80 ppbv.The temperate (T) is 25ºC.Convert the unit of…
Q: Propose an air pollution control device for an automobile factory that emits nitrogen oxides, carbon…
A: In general, every industry must have an air pollution control device. Air pollutants are generated…
Q: good filtration system is important for removal of pathogens using chlorine.
A: In the question it has been said that in a filtration system why we need to use chlorine for killing…
Q: Define water pollution. Differentiate filtration from chemical adsorption. Give two other water…
A: Kindly Note: As per our company guidelines only the first three interlinked questions. Kindly repost…
Q: Describe briefly the nature and operation of rapid gravity filters used in drinking water treatment.…
A: Solution: Rapid gravity filters are mostly used in drinking water treatment as they have proved to…
Q: Your engineering firm has been hired to design a new drinking-water treatment plant to treat water…
A: Given: Flow Rate = 3.1×106 L/hr Cross- Sectional area of each filter= 5m×5m Depth of layer of sand…
Q: The concentration of VSS in the returned flow rate to the aeration tank = 4000 mg/L while the MLVSS…
A: Given data- Aeration Tank-VSS concentration= 4000 mg/LMLVSS concentration= 2500 mg/LMLSS…
Q: For each of the following indicate if the designated technology is appropriate for the indicated…
A: (a) A 60-micron household filter for cryptosporidium. This is not appropriate as it will not work…
Q: Describe the safety precautions for 1 ton liquid chlorine containers (i) in manufacturing to prevent…
A: (1) Safety precautions for 1 ton liquid chlorine containers in manufacturing to prevent…
Q: In a wastewater treatment plant, the supply of oxygen supply is 073 kgO2/h is necessary…
A: Given data: oxygen supply under operating conditions, Ns = 73 kgO2 /kwh = 73 MJ Liquid temperature:…
Q: 10- To protect the Symon's rain gauge we should: a- put it inside a building are false b- put it…
A: Guidelines foe setting of a raingauge:* A raingauge must be surrounded by an open fenced area of…
Q: Inspection access Access for cleaning Inspection access Wastewater from house Scum Outlet to drain…
A: There Are different Parts of the Septic tank Are given. Our aim is to, Define each parts of the…
Q: Soda ash liquor having 1250 kg/m³ density and 1.2 cP viscosity flows through a 215m length of a…
A: Given: The density of soda ash liquor is 1250 kg/m³. The viscosity of the flow is 1.2 cP. The length…
Q: 6. A biodegradable fuel having a specific gravity of 0.95 and a viscosity of 0.04 grams per cen-…
A: Solution (6) Reynolds number of the biodegradable fuel is calculated by. Re =ρvDμv =Re ×μρD Where, ρ…
Q: Any of various receptacles for receiving water from a water system and discharging the liquid waste…
A:
Q: A water treatment plant has rapid sand filters. Each filter is 15 ft x 15 ft (square). Each filter…
A:
Q: Which of the following will not reduce water scarcity? a) Operate washing machine with full loads.…
A: This question is related to the Engineering Hydrology.
Q: Describe briefly the nature and operation of dissolved air flotation used in drinking water…
A: Flotation is a unit operation , which is used in the wastewater treatment for removal of lighter…
Q: A paper plant is being proposed for a location 1 km upwind from a town. It will emit 40 g/s of…
A: Schematic view of power plant From table 7.9 of Environmental Engineering and science( 3rd edition)…
Q: The local population is worried about their exposure to SO2 from Factory A mentioned in the previous…
A: As we all know that the concentration of impurities decrease as it moves in the atmosphere due to…
Q: A 25 ml of sewage water sample was refluxed with 10 ml 0f 0.25 N K2Cr2O7 solution. The untreated…
A: Given data Volume Refluxed volume Concentration Potassium dichromate volume
Q: Wastewater is treated with a certain amount of chlorine to remove 97% of micro-organisms present in…
A: Given data : Flow rate,Q = 35m3/h = 0.583 m3/min depth, D= 1.4 m width, W= 1.1 m rate of kill, k =…
Q: A groundwater supply has been designated as vulnerable to fecal contamination, and the state has…
A: given disinfection level = 99.99 % ( 4 log) virus pumping rate = 2000 gpm length of pipe = 4200 ft…
Q: For each of the following indicate if the designated technology is appropriate for the indicated…
A:
Q: Wastewater with DO concentration of 2 mg/L is discharged to a river. The temperature of the river is…
A:
Q: An effluent at flow rate of 2670 m3/day is to be treated. The dosage of chlorine is 15 mg/lt and the…
A: Given: Flow rate = 2670 m3/day Chlorine dosage = 15 mg/lt Disinfection model = Nt = Noe-0.145t
Q: For each of the following indicate if the designated technology is appropriate for the indicated…
A: Consider the first statement. A 60-micron household filter for cryptosporidium.
Q: determine the total mass of alkalinity consumed and the total mass of dry solids removed per day.
A: The values given in the question are as follows Average flow(Q)=0.044 m3/sec Alum dose=25 mg/L…
Q: Problem 2: A home is on fire, and to prevent its spread to the next house, firefighters are spraying…
A:
Q: It is attached to a drain that directs the wastewater into the sewer. bidets Toilet Urinal Sinks…
A: Answer - Faucets Explanation-. Faucets are used to control the flow of liquid as well as to…
Q: To help minimize any tendency for fine particles to migrate through the filter, and to drain as much…
A: Holes or slots are created in soil holding buildings such as retaining walls, underpasses, wing…
Q: A technician recovered 221⁄2 pounds of refrigerant R-12 for disposal by emptying5⁄6 of a pound of…
A: Given data, Total amount of R-12 refrigerant recovered = 22.5 lb Amount of refrigerant taken from…
Q: Q2) A new water storage tank with a volume of 950 m3 must be disinfected by filling with chlorinated…
A:
Q: - An aerobic digester with a total capacity of 50,000 ft³ stabilize waste-activated sludge from an…
A:
Q: The wastewater to be treated is flowing into the treatment plant at a rate of 2670 m3/day. The…
A: Given- η=98%K=0.145Q=2670m3/day
Q: An effluent at flow rate of 2760 m3/day is to be treated. The dosage of chlorine is 15 mg/lt and the…
A: Given: The flow rate is 2760 m3/day. The dosage of chlorine is 15 mg/lt. The disinfection model is…
Q: For each of the following indicate if the designated technology is appropriate for the indicated…
A:
Q: Describe briefly the nature and purpose of tertiary treatment processes in wastewater treatment such…
A: Treatment system of waste-water:
Q: Problem 7 - 69 Gasoline at 20°C (sp. gr. 0.719, 0.000292 Pa-s) flows at the rate of 2 L/s through a…
A:
Q: 14. A fire detector cannot detect: A. O Radiation В. Нeat С. O Light D. O Smoke
A: Using fire detector properties
Q: A gravity settling tank is to be used to clean wastewater for an oil refinery. The wastewater…
A: Answer We are given that Width = 2 ft depth = 4 ft diameter of droplets = 100 to 1000 microns Flow…
Q: Define desalination and provide illustrations Laboratory of sanitary engineering The free chlorine…
A: Note: Hi! Thank you for the question as per the honour code, we’ll answer the first question since…
Q: After using a fire extinguisher what must occur O Sec 54 (1) O Sec 54 (2) O Sec 55 O Sec 56
A: section 56 must occur after using the fire extinguisher
Q: Efficient Uneconomical Cost-effective Reliable Inefficient Unreliable
A: There is a conversation between Manager and Engineer about gas turbines
--------------------------- regulates drinking water collection, treatment and distribution, and requires the EPA to set national standards for drinking water quality.
Trending now
This is a popular solution!
Step by step
Solved in 2 steps
- Question - There is a small spill of a toxic material on a paved surface of a chemical plant. This spill has width 0.8 ft and a length of 2.5 ft. The wind is a 10 miles per hour in the direction parallel to the length of the spill. Estimate the rate of evaporation in grams per hour. There is no toxin in the air at time 0 and at infinite distance from the spill. Assume air to behave as an ideal gas. Assume the toxic material can be considered an ideal solution with psat = 22 mmHg. MWtoxin = 164.4 g/mol, Ptoxin =1.69 g/cm³, Pair = .001225 g/cm³, Hair= 0.0187 CP, MWair = 28.9 g/mol, Dtoxin,air = 0.0888 cm²/s.How many gallons of 12-percent sodium hypochlorite solution are needed to disinfect a reservoir 20 feet in diameter and 6 feet deep? An initial chlorine dose of 80 milligrams per liter (mg/L) is expected to maintain a chlorine residual of over 50 mg during the 24-hour disinfection period.Describe briefly the nature and operation of rapid gravity filters used in drinking water treatment. Use sketches where appropriate.
- QUESTION 2 Supposing you were part of the students who visited Barekease water treatment plant for a practical session during the semester in Kumasi. During the session, you had face to face interaction with the Water Engineer in charge of the chemical treatment unit a.) Discuss four (4) key factors that affect the selection of a disinfectant ) Examine five factors that influence disinfection efficacy and microbial inactivation ) A dual media filter is composed of 0.30 m anthracite (mean particle size 0.20 mm) that is placed over a 0.60 m layer of sand (mean particle size 0.70 mm) with a filtration rate of 9.78 m/h. Assume the grains sphericity ф= 0.75and porosity (ε)=0.40. Determine the head loss in the clean filter?For each of the following indicate if the designated technology is appropriate forthe indicated water-quality problem. Explain why or why not (answer in no morethan a few sentences).a. A 60-micron household filter for cryptosporidium.b. Ion exchange for waste contaminated by radioactive cesium and strontium.c. A strong-base ion exchange resin for nitrate.d. Slow sand filtration for highly turbid water.e. Activated carbon for groundwater contaminated by BTEX (benzene, toluene,ethylbenzene, and xylene) from a gasoline spill.f. Filtration for taste and odour.g. Lime treatment for hardness of 90 mg/L as CaCO3.h. Ion exchange for hardness of 90 mg/L as CaCO3.i. Lime treatment for iron.j. Suspended sediment removal in a vigorously mixed fully-mixed tank.For each of the following indicate if the designated technology is appropriate for the indicated water-quality problem. Explain why or why not (answer in no more than a few sentences). e. Activated carbon for groundwater contaminated by BTEX (benzene, toluene, ethylbenzene, and xylene) from a gasoline spill. f. Filtration for taste and odour. g. Lime treatment for hardness of 90 mg/L as CaCO3.
- ______________ air pollutants are those with absolute national ambient air quality limits,whereas ________________ air pollutants need to be removed using best applicable controltechnologies (BACTs) Fill in the blanksChoices. (a) criteria, hazardous (b) hazardous, criteria, (c) toxic, particulate (d) PM2.5, organicAs the project engineer for your consulting firm, you are in charge of designing a flocculation tank to treat municipal drinking water. The design flow for the plant is 0.050 m3/s. The average water temperature is 10oC. The following design assumptions for the flocculation basin have been made:Number of tanks = 1Number of compartments in tank: 3Tapered G in 3 compartments: 60, 50, and 20 s-1Detention time = 30 min for entire flocculation basinDepth = 3 mTanks will have a square compartment plan (overhead) view1 Horizontal shaft paddle wheel per axis will be usedPaddle wheels will have 4 arms and 2 blades/armPaddle blades are 3 m long by 0.6 m wide. Assume blade spacing (diameter) of 1 and 2 m. Design the flocculation tank by providing the following for the first two compartments only:a) Tank and compartment dimensions in mb) Water power input in kWc) Rotational speed of the paddle wheel shaft in rpmThe air pollution control equipment on a municipal waste incinerator includes a fabric filter particle collector (known as a baghouse). The baghouse contains 424 cloth bags arranged in parallel, that is 1/424 of the flow goes through each bag. The gas flow rate into and out of the baghouse is 47 m3/s, and the concentration of particles entering the baghouse is 15 g/m3. In normal operation, the baghouse particulate discharge meets the regulatory limit of 24 mg/m3. when all 424 bags are in place and the emissions comply with the regulatory requirements: a) Calculate the fraction of particulate matter removed. b) Calculate the efficiency of particulate removal.
- Sanitary engineering laboratory The residual chlorine (Free chlorine) test write about everything The residual chlorineEnvironmental Engineering Lab what is the Standard test method to determine biochemical oxygen demand of a given water sample Please add your answer this : Theory Significance Guidelines Apparatus / ChemicalsUsed ProcedureThe Philippine Toxic and Hazardous Wastes Act places limits on the quantities of toxic substances thatmay be discharged into the sewerage system. Guidelines on hexavalent chromium (Cr6+) limits the dischargeamount to just 0.50 mg/L. If an industry dumps hexavalent chromium in the form of potassium dichromate(K2Cr2O7), what is the maximum allowable concentration of hexavalent chromium in % by volume and molesper liter of sewage water? Molar Mass: Cr=52, K=39.1, O=16