Suppose Megan needs to transfer 5.00 mL of a liquid with high precision and accuracy. Which of the following pieces of glassware should Megan use? Hint: Compare the average percent errors, calculated from the sample data provided, for the buret and pipet trials. 5-mL pipet 25-mL buret 10-mL graduated cylinder O 10-ml pipet
Q: llet leaving the muzzle of a pistol was trave mi/hr Texthook and Media
A:
Q: What is one effective way to calibrate a thermometer?
A:
Q: solution stock Concentration (mL) (mL) (HM) 0.100 100.00 Q2a 0.200 100.00 0.400 100.00 4 0.800…
A: Dilution refers to decreasing the concentration of solute in a solution. This is done by adding…
Q: acia SOluti Select one: -5 а. 1.33 х 10 М -4 b. 3.76 x 10 'M -5 C. 2.66 x 10 M -5 M d. 5.32 x 10
A: Answer - The correct option is (d) 5.32*10^-5
Q: nitroglycerin contain the following amounts of drug 1/25gr, 1/10gr and 1/50gr. Express these…
A: As we know, conservation, 1 gr = 1000 milligrams A) 1/25 gr = 1×1000/25 = 40 milligrams B)…
Q: Give the name of the following lab equipment: Erlenmeyer flask Pipette with pump pH paper Test tube…
A: There are various equipment in lab , knowing there name is essentional to do practical with…
Q: 0.2 to 1.0 mg/ml: For each concentration, a volume of 1.0 mL should be prepared. How will you…
A: The volume of the solution that can be measured with 5-10 microliter pipette and 2-20 microliter…
Q: What is the volume reading of the liquid in the graduated cylinder? * 40 -35 -30 -25 20 36.50 + 0.05…
A: The point where the lower meniscus of liquid is in the graduated cylinder, that indicates the…
Q: At the diagram of the simple distillation apparatus and label the following parts or general areas:…
A: The process in which the separation of components from the mixture of liquid by using the…
Q: 1000 mL of 0.45% NaCl IV for 6.5 hours Drop factor: 60 gtt/mL Flow rate: ________ gtt/min
A: IV flow rate An IV flow rate is a way of describing the rate of an intravenous infusion based on the…
Q: Answer the following questions. _____1. Which of the ff you can use for mixing liquids? a) test tube…
A: 1) The tool which is used for mixing liquids is stirring rod. Therefore, the correct answer is…
Q: 1) determine the glassware that can be used to deliver 4.5mL with an absolute error: a) ≤ 0.15 mL…
A: Answer - Absolute error - The absolute value of the difference between an observed value of a…
Q: why do you calibrate thermometers and pipets?
A: Calibrate means correlate the result with standard instruments reading.
Q: You have a stock solution certified by a manufacturer to contain 175.0 z 0.3 wg SO;"/ml. You would…
A:
Q: Identify the carbon atoms that give rise to each NMR signal.
A: The first molecule is butan-2-ol. There are four peaks obtained in the NMR signaling. Four…
Q: Which of the following is NOT true about constant weighing in the experiment? A A proportionality…
A: Weighing is an important and necessary part of the experiment. If the amount of compound is not…
Q: You need to precisely measure 10.0 mL of liquid. What tool should you use? O 50 mL graduated…
A: There are various apparatus that is used in a chemistry lab while doing an experiment. Few examples…
Q: 3. Gas Chromatography. Answer the following questions based on what you know about the GC in our…
A: The separation of the individual compounds in a mixture can be best accomplished by using the…
Q: Observations: Burette Reading (ml) Normality of a520 solution (N) Volume of NaSy02 soution (m)…
A: The amount of oxygen present in one liter of water in a dissolved state is called dissolved oxygen.…
Q: tudent needs 25.0 mL of 9.60x10 e No. 6 stock solution to work with, how much of the 2.00 mM…
A: Formula used M1V1 = M2V2 where M= Molarity and V= volume
Q: 10 9 d (ppm) 3₂ 2 7 6 5 1.00 4 1.00 3 1.50 1.50 2 0
A: As per the rules, only the first question can be answered.
Q: The volume of the solution that can be measured with 5-10 microliter pipette and 2-20 microliter…
A: Volume of solution that is measured using a 20-200 microliter pipette is 0.02 mL to 0.2 mL. Hence,…
Q: What is the most positive characteristic of a Thermoluminescence dosimeter compared to film badges
A: The thermoluminescence dosimeter (TLD) involves the measurement of the ionizing radiation on…
Q: Place 10 drops of the solution to be analyzed, mix thoroughly and centrifuge. ordinary test tube…
A: A centrifuge is a device that uses centrifugal force to separate materials. It separates the…
Q: how to get from molairty to millliters? in conversion factors
A:
Q: What is the correct burette reading? 25.3 mL 24.15 mL 25.85 mL 24.1 mL
A: In volumetric analysis the burette is used to measure the volume of the solution which is filled in…
Q: a = 4.42° C = 0.1g.mr' | = 10cm - 44.2° +4.42° +0.442° +44.2° ar selectior
A: We will use relation of specific rotation and concentration
Q: etention volumes are 6ml and 7mL, respectively. The dead volume of the column used is 1n
A:
Q: What should you write in your lab notebook if you measure 10 mL of a liquid as accurately as you can…
A: There are different types of glassware which are being used while performing any sort of experiment…
Q: the extraction
A: The question you uploaded is multiple questions. According to the Guidelines, if there are multiple…
Q: How large volume should be measured from a 37wt, 1.185 g/cm^3 density solution?
A:
Q: Chemistry 1) Take 1 mL of a liquid bacterial culture (aka original culture) and mix it with 9 mL of…
A:
Q: There are no different between volumetric and graduated pipettes
A: false there is a difference between between graduated pipette and volumetric pipette graduated…
Q: Calculate range of volumes representing 0.1% tolerance of a 25.00 mL volumetric pipette assuming…
A:
Q: Watchglass Bent glass hook Arrangement for the drying of samples. It shows the recommended way to…
A: false, as the reagent is not covered the lid of the bottle as well as the beaker beak is open…
Q: Active Raw Materials Actual Yield Formulation Dosage Form Packaging Ingredient Potassium 3 kgs.…
A:
Q: The following volumes of 0.000300 M SCN are diluted to 15.00 mL. Determine the concentration of SCN…
A: Given that, the following volume of 0.000300 M SCN- is diluted to 15.0 mL. We have to calculate the…
Q: First you drop a plastic bead that has a density of 0.32 g/cm into the column. What do you expect to…
A: Density is given by the formula d = m/V where d stands…
Q: what is the precision of the 3 graduated cylinders? show solution.
A: Here, volume of cylinder 1 = 100 mL Volume of cylinder 2 = 3mL Volume of cylinder 3 = 0.3 mL
Q: Questions and Problems Q.4 An IV pump delivers the following volume of saline solution over 4 hours.…
A:
Q: Limitation of accuracy of the following instruments: a. analytical balance b. top-loading balance…
A: “Since you have posted a question with multiple sub-parts, we will solve first three sub-parts for…
Q: Why is the pipette more precise than a burette when measuring?
A: Burettes are larger than a pipette, it has a stopcock at the bottom to control the release of…
Q: 1000 mL of 0.45% NaCl IV for 3 hours Drop factor: 20 gtt/mL Flow rate: ________ gtt/min
A:
Q: Select the piece of equipment that should be used to carry out the specified task in each example.…
A:
Q: S1: Revisit Luisa could you change L "small particles" more accurate Ultrascope views? 52: Examine…
A:
Q: If an uncalibrated 5 (±0.03) mL pipet is used to deliver a total of 15 mL, what is the uncertainty…
A: Given data: The volume of pipette used=5 mL The error in the volume of 5 mL pipette=±0.03 mL The…
Q: The glass pycnometer is an instrument used for measuring weights and densities of liquids in the…
A: The solubility of a substance indicates that the quantity of the substance that passes into the…
Q: If you will measure 90µl of liquid, what pipet calibration should you use appropriately? O 10µl -…
A: A pipette is laboratory glassware used for the accurate measurement of the volume of a liquid.
Q: What is the precision of a 100-mL beaker? " 100ml APPROX 80 100ml 60 40 20 + 10 O + 20 What is the…
A: Precision is the degree of exactness with which the object is measured. Generally, a smaller value…
Q: Stock strength of a drug is 50mg/2ml a client weight is administered 25mg/ kg what volume of drug…
A: Here is your solution
Trending now
This is a popular solution!
Step by step
Solved in 2 steps with 2 images
- 1. Calculate the experimental density of a salt solution and the percent error (same as relative error percent) using some or all the data given below. solubility of NaCl salt in water: 0.357 g/mLmass of empty graduated cylinder: 25.19g mass of graduated cylinder + salt solution: 30.47g total volume of salt solution: 4.98 mLtrue density of salt solution: 1.07 g/mLGive two examples of the Scale Factor Error (one of the types of systematic error). Please do not give what is already given in the example. I need it ASAP Thank youA method to determine an antibiotic was developed and validated in a pharmaceutical company. The method allows analysis of 100 mg tablets containing 7.5 mg of the antibiotic. According to the validation data, the confidence limits are 7.50 mg± 0.04mg. How many samples will need to be analyzed for an analyst to ensure that the content of the antibiotic in a macerated sample of that drug is 7.50 mg ± 0.03 mg with 95% reliability when analyzing 100 mg of the macerated sample?
- (a) Explain the difference between systematic and random errors. State whether the errors in (b)–(e) are random or systematic. (b) A 25-mL transfer pipet consistently delivers 25.031 + 0.009 mL when drained from the mark. (c) A 10-mL buret consistently delivers 1.98 6 0.01 mL when drained from exactly 0 to exactly 2 mL and consistently delivers 2.03 6 0.02 mL when drained from 2 to 4 mL. (d) A 10-mL buret delivered 1.983 9 g of water when drained from exactly 0.00 to 2.00 mL. The next time I delivered water from the 0.00 to the 2.00 mL mark, the delivered mass was 1.990 0 g. (e) Four consecutive 20.0-mL injections of a solution into a chromatograph were made (as in Figure 0-6) and the area of a particular peak was 4 383, 4 410, 4 401, and 4 390 units. (f) A clean funnel that had been in the lab since last semester had a mass of 15.432 9 g. When filled with a solid precipitate and dried thoroughly in the oven at 1108C, the mass was 15.845 6 g. The calculated mass of precipitate was…Answer in scientific notation with appropriate sigfigs. A drink mix sample is prepared by mixing a packet of beverage powder in a gallon (3.78 L) of water. A sample for analysis is prepared by diluting 10.00 mL of this solution in a 50.0 mL volumetric flask. When measured using a colorimeter, this diluted solution has an absorbance of (3.49x10^-1). The calibration curve for the experiment yielded a linear fit of y = (2.650x10^4)x+(4.215x10^-2) and an R2 value of 0.9911. Determine the molar concentration of food dye in the sample.Answer the question in full details: Is it possible for a volumetric pipette to have a high precision but low accuracy? How could this situation arise?
- Express 20,000ppb as a percentage strength A. 2% B. 0.02% C. 0.00002% D. 0.002%Indicate which of the following are determinate and indeterminate errors. a. A hygroscopic sample is not dried in the oven prior to weighing.b. The burette reading of 28.43 mL is written downs to 28.34 mL.c. The bottom of the meniscus in the burette is estimated to be at the zero-milliliter mark but in fact, is very slightly below this mark.d. The liquid in a 10 mL TD pipet is blown out by mouth.e. The rest point of a meter needle, oscillating due to some desktop vibration, is estimated incorrectly.For devices in which variable volumes can be measured “by eye”, you are entitled to estimate (interpolate) between the finest divisions of any scale on the device. For a graduated cylinder, the finest division is 0.2 mL, for the beaker, it is probably greater than 1 mL,. The volumetric pipetter is not a variable volume device; it only measures the indicated volume; for a 10 mL pipette at the index mark, it is accurate to 0.01 mL What should you write in your lab notebook if you measure 10 mL of a liquid as accurately as you can by eye using each of these devices? a) graduated cylinder b) beaker c) volumetric pipette
- Two aqueous hydrogen bromide solutions containing 1.00 wt% HBr (SG=1.0041) and 60.0 wt% HBr (SG=1.6731) are mixed to form a 3.54 M HBr solution (SG=1.1935). What feed rate of the 60.0 wt% HBr solution would be required to produce 1350 kg/hr of product?You are checking the accuracy of a volumetric flask marked 10.00 mL . To calculate the volume of water contained in the flask, you first measure the mass of the empty flask and the mass of the flask filled with water and take the difference. Then, you correct for the buoyancy factor and divide by the density of the water. The result of 8 such measurements is given in the table. Calculate the 95% confidence interval for these measurements with a mean of 10.03.The torsion prescription balance has a sensitivity requirement of 0.004 g. and an error of not more than 5%. What is the Minimum measurable quantity?