When the well-isolated office room is entered in the summer, it is seen that the temperature of the room is °C. After operating the air conditioner, the temperature of the room becomes 22 °C within At minutes. The fficient of performance of the air conditioning system is 2.5, a) find the internal energy changing in the room b) calculate the electrical power consumed by the system. Assume that the whole mass inside the room is ivalent to 700 kg of air. Take Cy = 0.72 kJ / kg°C, C, = 1.0 kJ / kg°C for air. Use the below table for At value. Last one digit of your student number Point:) At Win (minutes) 15 1 14 (A/C 35 °C 2 13 12 4 11 22 °C 10 7 8 8 7 9.

Principles of Heat Transfer (Activate Learning with these NEW titles from Engineering!)
8th Edition
ISBN:9781305387102
Author:Kreith, Frank; Manglik, Raj M.
Publisher:Kreith, Frank; Manglik, Raj M.
Chapter8: Natural Convection
Section: Chapter Questions
Problem 8.12P: 8.12 An electric room heater has been designed in the shape of a vertical cylinder 2 m tall and 30...
icon
Related questions
Question

Thermodynamics 

When the well-isolated office room is entered in the summer, it is seen that the temperature of the room is
°C. After operating the air conditioner, the temperature of the room becomes 22 °C within At minutes. The
fficient of performance of the air conditioning system is 2.5, a) find the internal energy changing in the room
b) calculate the electrical power consumed by the system. Assume that the whole mass inside the room is
ivalent to 700 kg of air. Take Cy = 0.72 kJ / kg°C, C, = 1.0 kJ / kg°C for air. Use the below table for At value.
Last one digit
of your student
number
Point:)
At
(minutes)
Win
15
1
14
(A/C
35 °C
2
13
12
4
11
22 °C
10
9
7
8
8
7
9.
Transcribed Image Text:When the well-isolated office room is entered in the summer, it is seen that the temperature of the room is °C. After operating the air conditioner, the temperature of the room becomes 22 °C within At minutes. The fficient of performance of the air conditioning system is 2.5, a) find the internal energy changing in the room b) calculate the electrical power consumed by the system. Assume that the whole mass inside the room is ivalent to 700 kg of air. Take Cy = 0.72 kJ / kg°C, C, = 1.0 kJ / kg°C for air. Use the below table for At value. Last one digit of your student number Point:) At (minutes) Win 15 1 14 (A/C 35 °C 2 13 12 4 11 22 °C 10 9 7 8 8 7 9.
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Basic Thermodynamic Processes
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Principles of Heat Transfer (Activate Learning wi…
Principles of Heat Transfer (Activate Learning wi…
Mechanical Engineering
ISBN:
9781305387102
Author:
Kreith, Frank; Manglik, Raj M.
Publisher:
Cengage Learning