Concept explainers
A chiller is providing 5 tons of cooling to an air handler by cooling water transfer between the two devices. The chiller is drawing 3.5 kw of electrical power during this operation. At what rate must the chiller dump energy to the environment (say to a cooling tower) in Btu/hr to satisfy the first law of
Want to see the full answer?
Check out a sample textbook solutionChapter 1 Solutions
Heating Ventilating and Air Conditioning: Analysis and Design
Additional Engineering Textbook Solutions
Mechanics of Materials
INTERNATIONAL EDITION---Engineering Mechanics: Statics, 14th edition (SI unit)
Degarmo's Materials And Processes In Manufacturing
Manufacturing Engineering & Technology
Thinking Like an Engineer: An Active Learning Approach (3rd Edition)
Mechanics of Materials (10th Edition)
- The kitchen, bath, and other ventilation fans in a house should be used sparingly since these fans can discharge a houseful of warmed or cooled air in just one hour. Consider a 200-m2 house whose ceiling height is 2.8 m. The house is heated by a 96 percent efficient gas heater and is maintained at 22°C and 92 kPa. If the unit cost of natural gas is $1.20/therm (1 therm = 105,500 kJ), determine the cost of energy “vented out” by the fans in 1 h. Assume the average outdoor temperature during the heating season to be 5°C.arrow_forwardAn oil-transfer pump uses 1 kW of power in transferring 5 kg/s of oil through a 3-cm-diameter pipe. The changes in kinetic and potential energies are essentially zero, and the process is adiabatic. Additionally, there is no appreciable temperature change in the oil, which has a density of 1500 kg/m³. Determine the change in pressure from inlet to exit.arrow_forwardSteam turbine is receiving a 1,831 lb/hr of steam, determine the kW output of the turbine if the work done by the steam is 1,906 BTU/lb.arrow_forward
- During a process, 50 kJ of work is done on a closed system while 20 kJ of heat is lost from the system. If the initial internal energy of the system is 90 kJ, what is the final internal energy of the system?arrow_forwardWater with density 1000 kg/m3 and gauge pressure 31.5 kPa flows through a ground level pipe with speed 12 meters/sec. Determine the work potential of this water in kJ per kg.arrow_forwardSteam flows into a turbine at the rate of 10 kg/s and 10 KW of heat are lost from the turbine. Ignoring elevation and kinetic energy effects, calculate the power output from the turbine. Given: h1 = 2739.0 kJ/kg : h2 = 2300.5 kJ/kg.arrow_forward
- Three hundred kilojoules of heat is added in a piston cylinder arrangement containing air causing it to expand in a polytropic process. If the polytropic exponent is 1.2 (PV^1.2 = c), determine the work done.arrow_forward5. A 4-m x 5-m x 7-m room is heated by the radiator of a steam-heating system. The steam radiator transfers heat at a rate of 10,000 kJ/h, and a 100-W fan is used to distribute the warm air in the room. The rate of heat loss from the room is estimated to be about 5000 kJ/h. If the initial temperature of the room air is 10°C, determine how long it will take for the air temperature to rise to 20oC. Assume constant specific heats at room temperature where C of AIR = 0.768kJ/kg-K. draw a figure also, and explain each step by step solution.arrow_forwardA building with an internal volume of 400 m3 is to be heated by a 30-kW electric resistance heater placed in the duct inside the building. Initially, the air in the building is at 14°C, and the local atmospheric pressure is 95 kPa. The building is losing heat to the surroundings at a steady rate of 450 kJ/min. Air is forced to flow through the duct and the heater steadily by a 250-W fan, and it experiences a temperature rise of 5°C each time it passes through the duct, which may be assumed to be adiabatic. How long will it take for the air inside the building to reach an average temperature of 24°C?arrow_forward
- A building with an internal volume of 400 m3 is to be heated by a 30-kW electric resistance heater placed in the duct inside the building. Initially, the air in the building is at 14°C, and the local atmospheric pressure is 95 kPa. The building is losing heat to the surroundings at a steady rate of 450 kJ/min. Air is forced to flow through the duct and the heater steadily by a 250-W fan, and it experiences a temperature rise of 5°C each time it passes through the duct, which may be assumed to be adiabatic. Determine the average mass flow rate of air through the duct.arrow_forwardA hydraulic turbine is used to generate power by using water in a dam. The elevation difference between the free surface stream and the downstream of the dam is 120 m. The water is supplied to the turbine at a rate of 150 kg/s. if the shaft power output from the turbine is 155 KW, the efficiency of the turbine is A. 0.85 B. 0.77 C. 0.80 D. 0.88 F.B.Darrow_forwardA heat machine receives heat from a high-temperature heat source at a temperature of 160 °C andIt delivers heat to a high-temperature heat source at a temperature of 5 °C. In the meantime jobit is claimed that 0.15 kWh of work is done per every 1000 KJ of heat that the machine receivesare made. 1 if the claim is true. and 2. Evaluate according to the law.arrow_forward
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY