Chapter 1, Problem 1.54P
For the calibration data of Table 1.5, determine the static sensitivity of the system at (a) X = 5, (b) X = 10, and (c) X = 20. For which input values is the system more sensitive? Explain what this might mean in terms of a measurement and in terms of measurement errors.
Table 1.5 Calibration Data
X [cm] | r[V] | X [cm] | r[v) |
0.5 | 0.4 | 10.0 | 15.8 |
1.0 | 1.0 | 20.0 | 36.4 |
2.0 | 2.3 | 50.0 | 110.1 |
5.0 | 6.9 | 100.0 | 253.2 |
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
To measure the density of a stone, a digital scale and a beaker cup filled with water are used. The balance is used to measure the mass of the stone, while the beaker is used to measure the volume of the stone. It is known that the digital balance has a resolution of 0.1 g and that the beaker cup has a resolution of 5 ml. Repeated mass measurements return the following values: 250.0 g; 249.9 g; 250.3 g; 249.6g; 250.1 g; 249.7g; 250.4 g; 250.0 g; 248.8 g; 250.2 g The volume is measured only once. Placing the stone in the beaker, a volume of displaced water equal to 50 ml is measured. Using a k=2.5, check if the density of the stone is compatible or out of line with the value ρ = (4910 ± 65) kg.m-3
(a) none of the above
(b) the values are compatible
(c) missing data to perform the compatibility test
(d) the values are discrepant
A special sensor is designed to sense the percent vapor present in a liquid vapor mixture. If during a static calibration the sensor indicates 80 units when in contact with 100% liquid,0 units with 100% vapor ,and 40units with a 50:50% mixture,determine the static sensitivity of the sensor
1.The thickness of a gage block is measured five times using an instrument that has a resolution of 0.001 cm. The following measurements are obtained (in cm): 1.100, 1.110, 1.090, 1.095, and 1.105. The true gauge block thickness is known to be 1.050 cm. Use this information to answer the following questions:
a. What errors or sources of measurement error can be identified in the example? (Hint: there are three). Identify each one as a random or systematic uncertainty.
b. Estimate the magnitudes of each of these uncertainties. Wherever possible, estimate random uncertainties at a 95% probability/confidence level.
c. Based on the uncertainties determined in part b, estimate the overall uncertainty of a measurement obtained by this instrument.
Chapter 1 Solutions
Theory and Design for Mechanical Measurements
Ch. 1 - Prob. 1.1PCh. 1 - Prob. 1.2PCh. 1 - Prob. 1.3PCh. 1 - Prob. 1.4PCh. 1 - Prob. 1.5PCh. 1 - Discuss how the resolution of the display scale of...Ch. 1 - Prob. 1.7PCh. 1 - Prob. 1.8PCh. 1 - Prob. 1.9PCh. 1 - Prob. 1.10P
Ch. 1 - State the purpose of using randomization methods...Ch. 1 - Provide an example of repetition and replication...Ch. 1 - Develop a test plan that might be used to estimate...Ch. 1 - Develop a test plan that might be used to evaluate...Ch. 1 - A race engine shop has just completed two engines...Ch. 1 - A thermodynamics model assumes that a particular...Ch. 1 - Regarding the Mars Climate Orbiter spacecraft...Ch. 1 - A large batch of carefully made machine shafts can...Ch. 1 - Suggest an approach or approaches to estimate the...Ch. 1 - Suggest a test matrix to evaluate the wear...Ch. 1 - Figure 1.15 Orifice flow meter setup used for...Ch. 1 - The sale of motor fuel is an essential business in...Ch. 1 - Using either the ASME 19.5 or ISO 5167 test...Ch. 1 - A simple thermocouple circuit is formed using two...Ch. 1 - 1.25 A linear variable displacement transducer...Ch. 1 - For the LVDT calibration of the previous problem,...Ch. 1 - A manufacturer wants to quantify the expected...Ch. 1 - Prob. 1.28PCh. 1 - As described in a preceding problem, the...Ch. 1 - Light gates may be used to measure the speed of...Ch. 1 - You estimate your car’s fuel use by recording...Ch. 1 - When discussing concomitant methods, we used the...Ch. 1 - Prob. 1.33PCh. 1 - For the strain gauge calibration of the previous...Ch. 1 - The acceleration of a cart down a plane inclined...Ch. 1 - In general, what is meant by the term “standard”?...Ch. 1 - A common scenario: An engineer has two pencil-...Ch. 1 - Explain the potential differences in the following...Ch. 1 - Research the following test standards and codes....Ch. 1 - A hotel chain based in the United States contracts...Ch. 1 - Test code ASTM 558-13 allows for the comparison of...Ch. 1 - Suggest a reasonable number of significant digits...Ch. 1 - Using spreadsheet software (such as Microsoft...Ch. 1 - Prob. 1.44PCh. 1 - Round the following numbers to 3 significant...Ch. 1 - Express the result, rounding to an appropriate num...Ch. 1 - Express the result by rounding to an appropriate...Ch. 1 - A car’s speed is determined by the time it takes...Ch. 1 - How much error could you tolerate in (1) book...Ch. 1 - Apply the guidelines to determine the number of...Ch. 1 - Using a tape measure having 1 mm graduations, the...Ch. 1 - Show how the following functions can be...Ch. 1 - Prob. 1.53PCh. 1 - For the calibration data of Table 1.5, determine...Ch. 1 - Prob. 1.55PCh. 1 - Each of the following equations can be represented...Ch. 1 - Plot y = 10e“° 5x volts on in semilog format (use...Ch. 1 - Prob. 1.58PCh. 1 - Prob. 1.59P
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A displacement transducer has the following specifications: Linearity error:±0.25% reading Drift:±0.05%/°C reading Sensitivity error: ±0.25% reading Excitation: 10-25 V Output: dc 0-5Vdc Range: 0-5 cm The transducer output is to be indicated on a voltme- ter having a stated accuracy of 0:1% reading with a resolution of 10 μV. The system is to be used at room temperature, which can vary by 10 °C. Estimate an uncertainty in a nominal displacement of 2 cm at the design stage. Assume 95% confidence.arrow_forwardCase 1: Material system without density and viscosity differences Though unlikely in real life, in this case, we assume that all of the material in the homogenizer is of the same density and viscosity. Thus, only one set of material parameters are mentioned (density, ρ; dynamic viscosity, μ). The important parameters are listed as follows: Target quantity : Mixing time, θ Geometric parameters : Stirrer diameter, d Material parameters : Density, ρ Dynamic viscosity, μ Process-related parameters : Stirrer speed, n 1.1) Write out the relevance list for Case 1. 1.2) Generate the pi-set for this case. 1.3) Write out the appropriate pi (π) numbers from the generated pi-set. 1.4) Identify the established dimensionless numbers from the derived pi (π) numbers. 1.5) Write the possible relationship of the dimensionless numbers for Case 1.arrow_forwardWhat is an example of experimental uncertainty?arrow_forward
- Pressure distribution measurements are made on a two-dimensional wing model placed in a wind tunnel. The difference between the static pressure sockets on the surface and the static pressure of the free stream is measured. 30 data is taken at each measurement point. The average of the values measured from one of the sockets near the trailing edge was calculated as 2.30 Pa, and the standard deviation was calculated as 2.65 Pa. After applying the Chauvenet criterion to these measurement values, it was decided to eliminate 3 measurements and the new mean value was found to be 2.18 Pa and the standard deviation was 2.42. It was verified that the unexcluded data fit the normal distribution curve. Data above how many Pa and below how many Pa were eliminated? Estimate how many data have negative value (?<0) after elimination.arrow_forwardA displacement transducer has the following specifications: Linearity error: ±0.25% reading Drift: ±0.05%/°C reading Sensitivity error: ±0.25% reading Excitation: 10-25 V dc Output: 0-5Vdc Range: 0-5 cm The transducer output is to be indicated on a voltmeter having a stated accuracy of 0:1% reading with a resolution of 10 μV. The system is to be used at room temperature, which can vary by 10 °C. Assume 95% confidence. The displacement transducer above is used in measuring the displacement of a body impacted by a mass. Twenty measurements are made, which yield Determine a best estimate for the mass displacement at 95% probability based on all available information.arrow_forwardA displacement transducer has the following specifications: Linearity error: ±0.25% reading Drift: ±0.05%/°C reading Sensitivity error: ±0.25% reading Excitation: 10-25 V dc Output: 0-5Vdc Range: 0-5 cm The transducer output is to be indicated on a voltmeter having a stated accuracy of 0:1% reading with a resolution of 10 μV. The system is to be used at room temperature, which can vary by 10 °C. Assume 95% confidence. The displacement transducer above is used in measuring the displacement of a body impacted by a mass. Twenty measurements are made, which yield X= 17.20mm Sx= 1.70mm Determine a best estimate for the mass displacement at 95% probability based on all available information.arrow_forward
- n a certain dynamic measurement application the input(x) – output(y) relationship is given by y=1+(1+x)e^(-x) With what uncertainty must x be determined to yield a relative uncertainty of ±5 percent for y at a value of x = 2,4arrow_forwardMeasurement in Engineering Question is image C) ? c) Determine a 95% confidence interval for Nu and report the value.arrow_forwardPLS ANSWER ASAP. THANK YOU! The slope of the calibration curve is based on __________. a. calibration limit b. calibration sensitivity c. calibration detection d. calibration functionarrow_forward
- The mass of a solid hemisphere is measured once with a digital balance whose resolution is 1 g. The result is m = 50 g. With a caliper, the resolution of which is 0.05 mm, repeated measurements of the diameter D of the hemisphere are carried out. The values obtained for D: 100.30 mm; 100.00 mm; 100.60 mm; 100.10 mm; 100.25 mm; 100.50 mm; 100.40 mm; 100.20 mm; 100.30 mm; 100.35 mm. The result of measuring the mass m is: (a) (50 ± 1) g (b) (50.0 ± 0.58) g (c) (50.00 ± 0.58) g (d) (50.0 ± 0.5) garrow_forwardA company makes electrical resistors. The perfect resistor has a value of 400 ohms. A sample of 2000 resistors was tested and found to have a mean of 391.5 ohms and a standard deviation of 22.5 ohms. Assuming a normal distribution:a. How many resistors in the sample will have more than 440 ohms of resistance?b. How many resistors in the sample will have less than 360 ohms of resistance? note: you can use the frequency distribution table picture I attached.arrow_forwardQuestion 1 (a) Explain what you understand by the term Callibration. (b) Describe in details the process of calibrating a digital industrial thermometer. Question 2 (a) Explain the importance of Primary, secondary and tertiary standards employed in Metrology. (b) By giving appropriate examples outline the advantages and disadvantages of Line and end standards. Question 3 Describe the types of errors and defects encountered in measuring instruments used in metrology.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY
Elements Of Electromagnetics
Mechanical Engineering
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Oxford University Press
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:9780134319650
Author:Russell C. Hibbeler
Publisher:PEARSON
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:9781259822674
Author:Yunus A. Cengel Dr., Michael A. Boles
Publisher:McGraw-Hill Education
Control Systems Engineering
Mechanical Engineering
ISBN:9781118170519
Author:Norman S. Nise
Publisher:WILEY
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:9781337093347
Author:Barry J. Goodno, James M. Gere
Publisher:Cengage Learning
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:9781118807330
Author:James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:WILEY
What is Metrology in Mechanical Engineering? | Terminologies & Measurement; Author: GaugeHow;https://www.youtube.com/watch?v=_KhMhFRehy8;License: Standard YouTube License, CC-BY