A concreate wall a surface area of 20 m2 and a thickness of 0.30 m separates conditioned room air from ambient air. The temperature of the inner surface of the wall (T1) is maintained at
(a) Determine the heat loss
(a total of 11 data points for each thermal conductivity value). Tabulate the result for all three cases in one table. Also provide a computer-generated graph [Heat loss,
Want to see the full answer?
Check out a sample textbook solutionChapter 1 Solutions
Heat And Mass Transfer (asia Higher Education Engineering/computer Science Mechanica)
- 1.19 A cryogenic fluid is stored in a 0.3-m-diameter spherical container is still air. If the convection heat transfer coefficient between the outer surface of the container and the air is 6.8 , the temperature of the air is 27°C, and the temperature of the surface of the sphere is –183°C, determine the rate of heat transfer by convection.arrow_forwardA cooling system is to be designed for a food storage warehouse for keeping perishable foods cool prior to transportation to grocery stores. The warehouse has an effective surface area of 1860 m2 exposed to an ambient air temperature of 32C. The warehouse wall insulation (k=0.17W/(mK)) is 7.5 cm thick. Determine the rate at which heat must be removed (W) from the warehouse to maintain the food at 4C.arrow_forward3.16 A large, 2.54-cm.-thick copper plate is placed between two air streams. The heat transfer coefficient on one side is and on the other side is . If the temperature of both streams is suddenly changed from 38°C to 93°C, determine how long it takes for the copper plate to reach a temperature of 82°C.arrow_forward
- 1.60 Two electric resistance heaters with a 20 cm length and a 2 cm diameter are inserted into a well-insulated 40-L tank of water that is initially at 300 K. If each heater dissipates 500 W, what is the time required for bringing the water temperature in the tank to 340 K? State your assumption for your analysis.arrow_forwardHeat is transferred at a rate of 0.1 kW through glass wool insulation (density=100kg/m3) with a 5-cm thickness and 2-m2 area. If the hot surface is at 70C, determine the temperature of the cooler surface.arrow_forward1.10 A heat flux meter at the outer (cold) wall of a concrete building indicates that the heat loss through a wall of 10-cm thickness is . If a thermocouple at the inner surface of the wall indicates a temperature of 22°C while another at the outer surface shows 6°C, calculate the thermal conductivity of the concrete and compare your result with the value in Appendix 2, Table 11.arrow_forward
- A pipe carrying superheated steam in a basement at 10C has a surface temperature of 150C. Heat loss from the pipe occurs by radiation (=0.6) and natural convection (hc=25W/m2K). Determine the percentage of the total heat loss by these two mechanisms.arrow_forward2.2 A small dam, which is idealized by a large slab 1.2 m thick, is to be completely poured in a short Period of time. The hydration of the concrete results in the equivalent of a distributed source of constant strength of 100 W/m3. If both dam surfaces are at 16°C, determine the maximum temperature to which the concrete will be subjected, assuming steady-state conditions. The thermal conductivity of the wet concrete can be taken as 0.84 W/m K.arrow_forwardThe roof of an electrically heated home is 9 m long, 12 m wide, and 0.50 m thick, and is made of a flat layer of concrete whose thermal conductivity is k = 0.8 W/m · °C . The temperatures of the inner and the outer surfaces of the roof one night are measured to be 25°C and 5°C, respectively, for a period of half a day. Determine the rate of heat loss (hp) through the roof that night.arrow_forward
- The case-to-ambient thermal resistance of a power transistor that has a maximum power rating of 15 W is given to be 25°C/W. If the case temperature of the transistor is not to exceed 80°C, mark the power at which this transistor can be operated safely in an environment at 40°C.. a)Between 1.0 to 1.5 W b)Between 1.5 to 2.0 W c)Between 2.0 to 2.5 Warrow_forwardA 5 m long section of a steam pipe whose outer diameter is 10 cm passes through an open space at 30°C. The average temperature of the outer surface of the pipe is measured to be 150°C, and the average heat transfer coefficient on that surface is determined to be 180 W/m^2.k. Determine (a) the rate of heat loss through convection from the steam pipe and (b) the annual cost of this energy loss if steam is generated in a natural gas furnace, and the price of natural gas is 0.05 Rs/Kwh, consider a 250 working-day year.arrow_forwardOn a multi-layered rectangular wall, the thermal resistance of the first layer is 0.005 ° C / W, the resistance of the second layer is 0.2 ° C / W, and the third layer is 0.1 ° C / W.The overall temperature gradient in the wall is multilayered from one side. to the other side is 50 ° C. a. Determine the heat flux through the walls. = Answer watts / m2. b. If the thermal resistance of the second layer is changed to 0.3 ° C / W, what is the effect in% on heat flux, assuming the temperature gradient remains the same? = AnswerAnswer %.arrow_forward