Chapter 16, Problem 12R
To determine
Explain the term “cover”.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
6. Which of the following is a condition that a liquidtight flexible metal conduit must meet in order to be suitable as an equipment grounding conductor?
A. The conduit is terminated in listed fittings.B. For trade sizes 3/4 through 1 1/4, the conduit conductors contained in the conduit are protected by overcurrent devices rated
at 20 amperes or less.C. The combined length of the conduit and other tubing and conduit in the same ground-fault path exceeds six feet.
D. For trade sides 3/8 through 1/2, the circuit conductors contained in the conduit are protected by overcurrent devices rated not more than 60 amperes.
7. You're going to connect a surge protection device to a separately derived electrical system. In this situation, the surge protection device should be connected at
A. the load side of the first overcurrent protection device. B. the input to the transformer's primary winding.C. the end of the shortest branch circuit.D. the first connected IT cabinet.
8. What is another term…
Which of the following statements about equipment grounding conductors (EGCs) is true?A. The National Electrical Code permits the EGC to also perform as a grounding electrode conductor.B. More than one EGC must be used if multiple circuits are installed in a single raceway, cable, or cable tray.C. No current should be present in the EGC during normal operation.D. EGCs are required to be decreased in size to address voltage drop.
what section of the code prohibits supporting telephone wires from raceways that contain light or power conductors.
Chapter 16 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Ch. 16 - Prob. 1RCh. 16 - What are the circuit ratings? __________________Ch. 16 - Prob. 3RCh. 16 - Prob. 4RCh. 16 - Prob. 5RCh. 16 - a. How many lights are recommended for a one-car...Ch. 16 - From how many points in the garage of this...Ch. 16 - GFCI breakers or GFCI receptacles are relatively...Ch. 16 - The total estimated volt-ampere load of the garage...Ch. 16 - Prob. 10R
Ch. 16 - Prob. 11RCh. 16 - Prob. 12RCh. 16 - In the spaces provided, fill in the cover (depth)...Ch. 16 - What section of the Code prohibits embedding Type...Ch. 16 - Prob. 15RCh. 16 - When a box-cover unit is installed for an overhead...Ch. 16 - When outdoor receptacles are installed where a...Ch. 16 - In order to wire a post light, a homeowner...Ch. 16 - What concerns are there when installing a...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Is it permitted to use flexible metal conduit over 6 ft (1.8 m) in length as a grounding means? (Yes) (No) (Circle the correct answer.)arrow_forwardWhat section of the Code prohibits supporting fire alarm conductors from raceways that contain light or power conductors? NEC ______.arrow_forwardWhich section of the Code prohibits supporting coaxial cables from raceways that contain light or power conductors? NEC ______________arrow_forward
- Is it always necessary to attach the bare equipment grounding conductor of a nonmetallic-sheathed cable to the green hexagon-shaped grounding screw on a receptacle? Explain.arrow_forwardWhere insulated conductors are deflected within a wireway, either at the ends or where conduits, fittings, or other raceways or cables enter or leave the wireway, or where the direction of the wireway is deflected greater than ____, dimensions corresponding to one wire per terminal in Table 312.6(A) shall apply.arrow_forwardThe frames of ranges, wall-mounted ovens, counter-mounted cooking units, and clothes dryers under the conditions permitted for existing installations, ___ permitted to be connected to the grounded circuit conductor. Select one: a. shall not be b. can not c. may be d. shall bearrow_forward
- How and where is the grounding electrode conductor attached to the water pipe?arrow_forwardDoes the NEC allow metal raceways to be used with nonmetallic boxes? Yes __________ No __________, NEC __________arrow_forwardWhat is the largest size solid conductor that is generally permitted to be installed in a raceway?arrow_forward
- 10.a. Which of the following is a condition of the exception that allows the grounded conductor of feeders tobe used for grounding at separate buildings or structures?A. There are common electrically continuous metallic paths between the feeder source and the destination at the structure served.B. There are common electrically continuous nonmetallic paths between the equipment grounding conductor and the destinationat the structure served.C. An equipment grounding conductor isn't included with the supply circuit to the separate structure.D. Ground-fault protection of equipment is provided on the supply side of the feeder.10.b. A service disconnection means must be installed adjacent to, within sight of, and no more than_______ feet from a mobile home.A. 20B. 30C. 10D. 50arrow_forwardAssuming that an outlet box for the entry ceiling has a fixture stud but has external cable clamps, what size box could be installed? Show calculations for both metal and nonmetallic boxes. ___________arrow_forwardIf you use 600-volt rated conductors for Class 2 wiring, does the Code permit pulling these conductors through the same raceway as the power conductors? (Yes) (No) (Circle the correct answer.) Give the NEC section number. ____________arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT