Question
Chapter 20, Problem 20.2QAP
Interpretation Introduction
Interpretation:
The difference between the spectra of EI, field ionization and the CI sources is to be stated.
Concept introduction:
Ionization refers to the process in which an atom or a molecule obtains a positive or a negative charge by losing or gaining an electron. This results in the synthesis of an ion. There are a variety of ionization methods. These include chemical ionization, electron impact, electrospray ionization, field ionization etc.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
As pH changes, ho will absorbance change t the wavelength of the isosbestic point?
How can adsorption affect the c=c vibrational frequency in IR?
What is the molar extinction coefficient if the pathlength of the sample cell is 5.6mm and the absorbance of 62.5 M solution is 0.222?
6.342X10-3 L mole- cm-
6.342X10-3 L mole- mm-
6.342X10-4 L mole- mm-
6.342X10-4 L mole- cm-
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.Similar questions
- What is the Molar Absorption Coefficient for Fe(SCN)2+ (M/cm) if the path length of vial is 2.24cm and given the data in the pictures.arrow_forwardWhy is it necessary to buffer the solution with sodium acetate in the spectrophotometic determination of iron in FAS (ferrous ammonium sulfate or Mohr's salt)? Be specific.arrow_forward5 What would the effect of increasing sample pressure (while maintaining a fixed cell length) have on an FTIR spectrum. By ”cell” I mean the chamber holding the gas.arrow_forward
- The absorption coefficient of a glycogen-iodine complex is 0.20 at light of 450 nm. What is the concentration when the transmission is 40 % in a cuvette of 2 cm?arrow_forwardthe absorbance of an equilibrium mixture of Fescn2+ was measured at 447nm and found to be 0.319. What is the equilibrium concentration of FeSCN2+?arrow_forwardHow does the Hollow Cathode Lamp work during the quantitative analysis of Iron (Fe) in Atomic Absorption Spectroscopy?arrow_forward
- What are the necessary conditions for a metal isotope to be useful as a sources in mossbauer spectroscopy.arrow_forward6 Why standard solutions are used in Atomic absorption Spectroscopy (AAS) whereas UV-Vis molecular absorbance only extinction coefficient is necessary?arrow_forwardAs the pH changes, how will the absorbance change at the wavelength of the isosbestic point?arrow_forward
- A copper(II) sulfate solution of unknown concentration is placed in a colorimeter and an absorbance reading of 0.46 is recorded. Using the same solution cell, a 0.055 Μ solution of copper(II) sulfate gives an absorbance reading of 0.34. What is the concentration of the first solution?arrow_forwardi) Find the differences between the AES and XPS in terms of principle and information obtained from the spectra. ii) Why AFM is mostly utilized microscopic method for the determination of the thickness of the film?arrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage Learning
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning