Automotive Technology: A Systems Approach (MindTap Course List)
6th Edition
ISBN: 9781133612315
Author: Jack Erjavec, Rob Thompson
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Textbook Question
Chapter 21, Problem 2ASRQ
None of the engines gauges works: Technician A tests gauge operation using a scan tool. Technician B begins by checking the fuse and then checks for voltage at the last point common to all the malfunctioning gauges. Who is correct?
- Technician A
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
The suitability of a strain gauge data logger.
The Fusible plug in a boiler is used to prevent damage to the boiler:
OPTIONS:
1.May be
2.False
3.True
4.May not be
The pressure measured with the help of a pressure gauge is called absolute pressure.
Select one:
True
False
Chapter 21 Solutions
Automotive Technology: A Systems Approach (MindTap Course List)
Ch. 21 - True or False? A driver information center...Ch. 21 - What is the purpose of an IVR?Ch. 21 - Explain how an air-core gauge works.Ch. 21 - What are two ways to provide input for the...Ch. 21 - Describe the two types of instrument panel...Ch. 21 - What is the device found in some fuel tanks to...Ch. 21 - What is the correct way to check a coolant...Ch. 21 - What type of sending unit is typically used to...Ch. 21 - What is the major difference between an indicator...Ch. 21 - True or False? The ABS lamp turns on whenever the...
Ch. 21 - The indicator needle on a speedometer is held to...Ch. 21 - Which of the following uses a permanent magnet and...Ch. 21 - What type of memory is used to store the...Ch. 21 - Which of the following is not a true statement...Ch. 21 - Which of the following statements about oil gauge...Ch. 21 - While discussing what the maintenance reminders...Ch. 21 - None of the engines gauges works: Technician A...Ch. 21 - The oil pressure light stays on whenever the...Ch. 21 - A digital speedometer constantly reads 0 mph:...Ch. 21 - All gauges operate but read lower than normal:...Ch. 21 - When testing an engine temperature sensor:...Ch. 21 - The coolant temperature gauge stays low (cold)...Ch. 21 - While discussing the instrumentation on a Toyota...Ch. 21 - The TPM warning lamp is lit: Technician A says...Ch. 21 - The yellow electronic throttle control warning...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- While discussing the AWG system: Technician A says that most automotive wiring range from 0 to 4 gauge. Technician B says that the higher the gauge number, the larger the diameter of the wire. Who is correct? Technician A Technician B Both A and B Neither A nor Barrow_forwardWhich of the following statements about oil gauge circuits is not true? A switch can be used A thermistor can be used. A piezoresistive sensor can be used d An oil pressure gauge may not show actual oil pressure.arrow_forwardBefore installing a gauge on the high-pressure side of a system, you should do which of the following? A. Turn on the system. B. Turn off the system. C. Adjust the system to a neutral position. D. Have a cylinder approved by the DOT nearby.arrow_forward
- All gauges operate but read lower than normal: Technician A says that the connection to the instrument cluster may be corroded. Technician B says that the cluster s IVR may be open. Who is correct? Technician A Technician B Both A and B Neither A nor Barrow_forwardThe coolant temperature gauge stays low (cold) after die engine has been started and ran until the engine is hot Technician A says that the wires to the sending unit may be shorted together. Technician B says that the sending unit may be electrically open. Who is correct? Technician A Technician B Both A and B Neither A nor Barrow_forwardTrue or False: When troubleshooting a small system, the first step is to attach the high- and low-pressure gauges.arrow_forward
- Which of the following statements about manifold gauge sets is not true? An adapter is required for using R-12 gauges on an R-134a system. A manifold gauge set is used when discharging, charging, and evacuating and for diagnosing trouble in an A/C system. The gauge manifold is designed to control refrigerant flow. When the manifold test set is connected into the system, pressure is registered on both gauges at all times. R-134a service hoses have a black stripe along their length, the low-pressure hose is blue, and the high-pressure hose is red.arrow_forwardDetermine the statement is true or false ASAParrow_forwardWhile discussing the misfire monitor: Technician A says that while detecting type A misfires, the monitor checks cylinder misfiring over a 500-revolution period. Technician B says that while detecting type B misfires, the monitor checks cylinder misfires over a 1,000-revolution period. Who is correct? Technician A Technician B Both A and B Neither A nor Barrow_forward
- True or False? A lab scope is a visual voltmeter that shows voltage over a period of time.arrow_forwardWhich of the following uses a permanent magnet and two electromagnets? Air-core gauge Balancing coil gauge Quartz analog gauge D' Arsonval gaugearrow_forwardWhat voltages indicate good oil in the standard dielectric test of oil?arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Automotive Technology: A Systems Approach (MindTa...Mechanical EngineeringISBN:9781133612315Author:Jack Erjavec, Rob ThompsonPublisher:Cengage LearningRefrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage LearningElectrical Transformers and Rotating MachinesMechanical EngineeringISBN:9781305494817Author:Stephen L. HermanPublisher:Cengage Learning
Automotive Technology: A Systems Approach (MindTa...
Mechanical Engineering
ISBN:9781133612315
Author:Jack Erjavec, Rob Thompson
Publisher:Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
Electrical Transformers and Rotating Machines
Mechanical Engineering
ISBN:9781305494817
Author:Stephen L. Herman
Publisher:Cengage Learning
Mod-01 Lec-16 Basics of Instrumentation; Author: nptelhrd;https://www.youtube.com/watch?v=qbKnW42ZM5c;License: Standard YouTube License, CC-BY