The NEC is the only code reference used for electrical installations of all types of occupancies including dwelling for physically challenged persons. True or False?
QUESTION 9
When a ground wire is connected to an interior gas piping system and the underground portion of the gas pipe into the building is plastic, which of the following is (or are) true?
a
A.This would be approved by code as the gas pipe is only being bonded to the electrical system.
b
B.This installation would be approved by code, as the gas pipe is not a grounding electrode.
c
C.Both A and B
d
D.Neither A nor B
QUESTION 25
Type TC cable shall not be _____.
a.
installed where it will be exposed to physical damage
b.
all of these
c.
installed outside of a race-way or cable tray system, unless permitted in 336.10(4), 336.10(7), 336.10(9), and 336.10(10)
d.
used where exposed to direct rays of the sun, unless identified as sunlight resistant
Chapter 26 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Ch. 26 - In your own words, explain the terms alarm and...Ch. 26 - The requirements for household fire alarm systems...Ch. 26 - Do heat alarms and carbon monoxide alarms take the...Ch. 26 - Name two basic ways that smoke alarms are powered.Ch. 26 - Name the two types of smoke alarms.Ch. 26 - List the absolute minimum level of smoke alarm...Ch. 26 - Circle the correct answer from the following...Ch. 26 - Circle the correct answer from the following...Ch. 26 - Circle the correct answer from the following...Ch. 26 - Prob. 10R
Ch. 26 - Prob. 11RCh. 26 - An important but often overlooked requirement in...Ch. 26 - Carbon monoxide is ____________, and is...Ch. 26 - Circle the correct answer from the following...Ch. 26 - The wiring of more complex household fire alarm...Ch. 26 - Circle the correct answer from the following...Ch. 26 - Circle the correct answer from the following...Ch. 26 - Fire alarm cable generally used in more complex...Ch. 26 - When installing a fire alarm system or a complete...Ch. 26 - Residential sprinkler fire protection systems are...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Assuming that an outlet box for the entry ceiling has a fixture stud but has external cable clamps, what size box could be installed? Show calculations for both metal and nonmetallic boxes. ___________arrow_forwardRefer to the specifications in the back of this text following Chapter 33. a. What electrical codes must be conformed to? ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ b. What is the wiring method to be used in the workshop? ________________________________________________________________________ c. What size conductors are to be used for the lighting branch circuits? ______________________ AWG the small-appliance branch circuits? ______________________ AWG d. What section of the specifications tells us the size of the service entrance to be installed for this residence?arrow_forwardThe recessed fluorescent luminaires installed in the ceiling of the recreation room of this residence are connected with trade size flexible metal conduit. These flexible connections are commonly referred to as fixture whips. Does the flexible metal conduit provide adequate grounding for the luminaires, or must a separate equipment grounding conductor be installed? ________________arrow_forward
- The following is a layout of the lighting circuit for the Laundry, Powder Room, Rear Entry Hall, and Attic. Complete the wiring diagram using colored pens or pencils to indicate conductor insulation color. The GFCI receptacle in the Powder Room is not shown in the diagram because it is connected to a separate circuit, B21.arrow_forwardFor a single, nonmotor-operated electrical appliance rated greater than 13.3 amperes that has no marking that would indicate the size of branch-circuit overcurrent device, what percentage of the nameplate rating is used to determine the maximum size branch-circuit overcurrent device? _________________arrow_forwardan office building has an area of 36,000 sqft, and the number of receptacles is unknown. How many 2-wire, 20-ampere, 120-volt circuits do you need to plan for to supply both the lighting loads and the receptacles?arrow_forward
- Construction sites can be dangerous because of the manner in which extension cords, portable electrical tools, and other electrical equipment are used and abused. To reduce this hazard, 590.6(A) of the NEC requires that all 125-volt, single-phase, 15-, 20-, and 30-ampere receptacle outlets used for temporary wiring during construction must be _________________ protected.arrow_forwardPlans require the installation of surface-mounted fluorescent luminaires on the ceiling of a recreation room that is finished with low-density ceiling fiberboard. What sort of mark would you look for on the label of the luminaire? ________________________________________ ___________________________________________________________________________ ___________________________________________________________________________ ___________________________________________________________________________arrow_forwardWhere a building or structure is suplkied by more than one service, or a combination of branch circuits, feeders, and services, a permanent plaque or directory must be installed at each sertvice disconnect location denoting all other suplying that building or structure and the area served by each. A. Services B. Feeders C. Branch circuits D. All of the abovearrow_forward
- what section of the code prohibits supporting telephone wires from raceways that contain light or power conductors.arrow_forwarda. The Code requires a minimum of two small-appliance circuits in a kitchen. Is it permitted to connect a receptacle in a dining room to one of the kitchen small-appliance circuits? _______________ What Code section applies to this situation? _______________ b. Are outdoor weatherproof receptacles permitted to be connected to a 20-ampere small-appliance circuit? _______________ c. Receptacles located above the countertops in the kitchen must be supplied by at least _______________ 20-ampere small-appliance circuits.arrow_forwardWhen outdoor receptacles are installed where a cord will be plugged in permanently, such as in the case of decorative lighting, the cover must provide weatherproof integrity when the cord is plugged in. True or false? (Circle your answer and provide the NEC reference if the statement is true.) NEC ______________.arrow_forward