Question
Chapter 30, Problem 12R
To determine
Choose the correct option from the given statement for the enclosures of transformers and GFCIs and junction boxes having one thing in common.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
In the conduit layout shown in picture attached, determine how many wires are contained in each conduit between each piece of equipment. Identify each wire with a proper terminal marking, as shown in the example, above the disconnect switch.
16. The _______ point is where the facilities of the serving utility and the premises wiring connect.A. groundedB. neutralC. serviceD. bonding
18. Which of the following would help avoid the choke effect in grounding electrode conductors?A. Installing a main bonding jumperB. Using an approved polyvinyl chloride conduitC. Applying solder to the connectionD. Using bonding bushes on the ends of the raceway
Chapter 30 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
A Type NM cable carries a branch circuit to the outside of a building, where it terminates in a metal weatherproof junction box. From this box, a short length of EMT is installed upward to another metal weatherproof junction box on which is attached a cluster of outdoor floodlights. The first box is located approximately 24 in. (600 mm) above the ground. To Meet Code, do the metal boxes and metal raceway have to be grounded? Yes _______________ No _______________ NEC _______________.
arrow_forward
A homeowner wants to add 12 general-purpose receptacle outlets to the electrical drawings before the house is built, what additional load, in volt-amperes will they add to the service load calculation?
arrow_forward
When used as service equipment, a panelboard (load center) must be ______________________ that is suitable for use as service equipment, 230.66. If the panelboard (load center) contains the main service disconnect, it must be clearly marked ____________________________________, 230.70(B).
arrow_forward
It is generally understood that grounding and bonding together all metal parts of an electrical system and the metal shield of the cable television cable to the same grounding reference point in a residence will keep both systems at the same voltage level should a surge, such as lightning, occur. Therefore, if the incoming cable that has been installed by the CATV cable company installer has the metal shield grounded to a driven ground rod, does this installation conform to the NEC? ___________
arrow_forward
Determine the minimum number of cubic inches required for two 10 AWG conductors passing through a box, four 14 AWG conductors spliced in the box, two 12 AWG conductors terminating to a receptacle, and one 12 AWG equipment bonding jumper from the receptacle to the box.
arrow_forward
A residential air-conditioning unit is installed in the attic. a. Is a lighting outlet required? __________ b. What Code section applies? __________ c. If a lighting outlet is required, how shall it be controlled? __________ d. What Code section applies? __________ e. Is a receptacle outlet required? __________ f. What Code section applies? __________
arrow_forward
Which of the following is a term missing from the National Electrical Code but used by manufacturers of equipment that's suitable for use as service equipment?
Micro-grid
Selective coordination
Neutral disconnect link
Grounding triad
The _______ is required to be connected to the grounded conductor of the sensitive electronic system on the line side of the separately derived system disconnecting means.
main bonding jumper
equipment grounding terminal bus
neutral ground strap
neutral disconnect link
arrow_forward
True False Bonding must be accomplished around conduit connections whenever the fault current return path is suspect as well as when specifically required by the NEC
arrow_forward
NEC 590.6(A)(3) requires that all 125-volt and 125/250-volt, single-phase, 15-, 20-, and 30-ampere receptacle outlets used on a construction site that are a part of a portable generator have listed: (Circle the correct answer.) a. ground-fault circuit interrupter protection for personnel. b. grounding-type receptacles. c. twist-lock receptacles.
arrow_forward
What color are the faceplates in the bathrooms? Refer to the specifications. ________________
arrow_forward
_______ type receptacles must be installed on all 15- and 20-ampere branch circuits except for replacement receptacles as permitted by 406.4(D).
Select one:
a. AFCI
b. GFCI
c. Duplex
d. Grounding
arrow_forward
When a box-cover unit is installed for an overhead door operator, a time-delay dual-element fuse ampere rating would generally be sized at __________________ % of the units nameplate current rating.
arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Types of House Wiring - Types of Electrical Wiring - Electrical Wiring; Author: Learning Engineering;https://www.youtube.com/watch?v=A5P-buWX-dA;License: Standard Youtube License