Question
Book Icon
Chapter 4, Problem 4.6.9P
To determine

(a)

A A992 W shape with a nominal depth of 21 inches using LRFD.

Expert Solution
Check Mark

Answer to Problem 4.6.9P

W21×62

Explanation of Solution

Given information:

Steel Design (Activate Learning with these NEW titles from Engineering!), Chapter 4, Problem 4.6.9P , additional homework tip  1

D=90

L=260

Calculation:

Pu=1.2D+1.6LPu=1.2×90+1.6×260Pu=524kips

Assume Fcr=25ksi

Ag>PuϕcFcr=5240.90×25Ag>PuϕcFcr=23.29in2

Try the web size W21×93 (non-slender shape)

Ag=27.3in2,ry=1.84in

Effective slenderness ratio is given by

kLry=0.65×(15.33×12)1.84kLry=64.99<200

Fe=π2E(KLr2)Fe=π2×29,00064.992Fe=67.76ksi

Check for slenderness ratio

4.71EFy=4.7129,000504.71EFy=113.4>64.99

Fcr=0.658FyFe×50Fcr=0.6585067.76×50Fcr=36.71ksi

Nominal compressive strength is given by

Pn=FcrAgPn=36.21(27.3)Pn=1002kipsϕcPn=0.90×724.2ϕcPn=652kips>524kips(ok)

Check for web buckling from dimensions and properties table in the manual the width thickness ratio of the web is given by

htw=43.6

From the AISC section we have the equation

bt1.49Ef=1.4929,00036.21bt1.49Ef=42.17

Since htw>1.49Ef,

Local buckling should be checked

Width of the web is given by

b=d-2kb=d-2×1.19b=18.72in

Effective width is given by

be=1.92tEf[10.3443.6Ef]bbe=1.92×0.43029,00036.21[10.3443.629,00036.21]18.72be=18.2118.72

Calculate effective area

Aeff=A-tw(b-be)Aeff=20-0.430(18.72-18.21)Aeff=19.78in2

Critical stress is given by

4.71EQFy=4.7129,000(19.7820)504.71EQFy=114.1>66.43

Calculate the critical buckling stress as below

Fcr=Q(0.658QFyFe×50)Fcr=0.989(0.6580.989×5064.86×50)Fcr=35.94ksi

Calculate nominal compressive strength of column

Pn=FcrAgPn=35.94×20Pn=718.8kips(ok)

Try the web size W21×62,

Ag=18.3in2,ry=1.77in

Effective slenderness ratio is given by

kLr=0.65×(15.33×12)1.77kLr=67.56ksi

Calculate buckling stress

Fe=π2E(KLr2)Fe=π2×29,000(67.56)2Fe=113.4ksi>67.56

Fcr=0.658FyFe×50Fcr=0.6585062.71×42Fcr=35.81ksi

Calculate nominal compressive strength of column

Pn=FcrAgPn=35.81×18.3Pn=655.3kips(ok)

ϕcPn=0.90×655.5ϕcPn=590kips>524kips(ok)

Check for web buckling from dimensions and properties table in the manual the width thickness ratio of the web is given by

htw=46.9

From the AISC section we have the equation

bt1.49Ef=1.4929,00036.21bt1.49Ef=42.4

Since htw>1.49Ef,

Local buckling should be checked

Width of the web is given by

b=d-2kb=21-2×1.12b=18.76in

Effective width is given by

be=1.92tEf[10.3443.6Ef]bbe=1.92×0.40029,00035.81[10.3446.929,00035.81]18.76be=17.3518.76

Calculate effective area

Aeff=A-tw(b-be)Aeff=18.3-0.400(18.76-17.35)Aeff=17.74in2

Critical stress is given by,

4.71EQFy=4.7129,000(17.7418.3)504.71EQFy=115.2>67.56

Calculate the critical buckling stress as below

Fcr=Q(0.658QFyFe×50)Fcr=0.9694(0.6580.9694×5062.71×50)Fcr=35.07ksi

Calculate nominal compressive strength of column

Pn=FcrAgPn=35.07×18.3Pn=641.8kipsϕnPn=0.90×641.8ϕnPn=578kips>524kips(ok)

Try the web size W21×62,

Conclusion:

Therefore, size W21×62 of A992 W shape with a nominal depth of 21 inches used LRFD.

To determine

(b)

Select a A992 W shape with a nominal depth of 21 inches using ASD.

Expert Solution
Check Mark

Answer to Problem 4.6.9P

122.90kips

Explanation of Solution

Given information:

Steel Design (Activate Learning with these NEW titles from Engineering!), Chapter 4, Problem 4.6.9P , additional homework tip  2

D=90

L=260

Calculation:

Pa=D+LPa=90+260Pa=350kips

Assume Fcr=25ksi

Ag>PuϕcFcr=5240.90×35Ag>PuϕcFcr=16.63in2

Try the web size W21×62,

Ag=18.3in2,ry=1.77in

Effective slenderness ratio is given by

kLry=0.65×(15.33×12)1.77kLry=67.56<200

Fe=π2E(KLr2)Fe=π2×29,00067.562Fe=67.76ksi

Check for slenderness ratio

4.71EFy=4.7129,000504.71EFy=113.4>67.56

Fcr=0.658FyFe×50Fcr=0.6585062.71×50Fcr=35.81ksi

Pn=FcrAgPn=35.81(18.3)Pn=655.3kipsPnΩc=655.31.67PnΩc=392kips>350kips(ok)

Check for web buckling from dimensions and properties table in the manual the width thickness ratio of the web is given by

htw=46.9

From the AISC section we have the equation

bt1.49Ef=1.4929,00035.81bt1.49Ef=42.4

Since, htw>1.49Ef,

Local buckling should be checked

Width of the web is given by

b=d-2kb=21-2×1.12b=18.76in

Effective width is given by

be=1.92tEf[10.3443.6Ef]bbe=1.92×0.40029,00035.81[10.3446.929,00035.81]18.72be=17.3518.76

Calculate effective area

Aeff=A-tw(b-be)Aeff=18.3-0.400(18.76-17.35)Aeff=17.74in2

Critical stress is given by

4.71EQFy=4.7129,000(17.7418.3)504.71EQFy=115.2>67.56

Calculate the critical buckling stress as below

Fcr=Q(0.658QFyFe×50)Fcr=0.9694(0.6580.9694×5062.71×50)Fcr=35.07ksi

Calculate nominal compressive strength of column

Pn=FcrAgPn=35.07×18.3Pn=641.8kips(ok)PnΩc=641.81.67PnΩc=384kips>350kips(ok)

Conclusion:

Therefore, size W21×62 of A992 W shape with a nominal depth of 21 inches used ASD.

Want to see more full solutions like this?

Subscribe now to access step-by-step solutions to millions of textbook problems written by subject matter experts!
Students have asked these similar questions
f. Calculate the maximum safe load "P" in KN  Two A36 16mm Thick Steel Plates Are Connected By Four Rivets With Fv=152 MPa As Shown. Given: Rivet Dia  20 mm x=100 mm
Design the beam  to carry the load as shown in Figure.  Use rho max  with a strain in the tension bars equal to  0.004 and  in the design process use 60% of this rho max.    f’c= 21MPa  and fy=276MPa                                                                      What is the   Mu max  that is to be used in the  design? Determine the required base and effective depth  of the beam.  Round up your answers to the nearest 10mm  and use 2b=d Determine the most economical number of 20mm diameter bars required. Using the b and d from  letter  (b) determine the balanced As for the  beam.
design a section of a concrete beam reinforced for tension only. The beam is simply supported on a span of 6 m and carries a load of 18 kn/ m. What stirrup will be required? Use fc’ = 17.2 MPa, fs = 124 MPa, n = 12. Assume b = d/2.