Steel Design (Activate Learning with these NEW titles from Engineering!)
6th Edition
ISBN: 9781337094740
Author: Segui, William T.
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Question
Chapter 4, Problem 4.9.7P
To determine
(a)
The nominal compressive strength
ii.
To determine
To find:
The percentage difference.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A cantilever beam AB of length L = 6.5 ft supportsa trapezoidal distributed load of peak intensity q,and minimum intensity q/2, that includes the weight ofthe beam (see figure). The beam is a steel W12 X14wide-flange shape (see Table F-1(a), Appendix F).Calculate the maximum permissible load q basedupon (a) an allowable bending stress σallow =18 ksiand (b) an allowable shear stress τallow = 7.5 ksi.Note: Obtain the moment of inertia and section modulusof the beam from Table F-1(a).
A hollow steel [E = 30,000 ksi] tube (1) with an outside diameter of 3.00 in. and a wall thickness of 0.223 in. is fastened to a solid 1.75-in.-diameter aluminum [E = 10,000 ksi] rod. The assembly is attached to unyielding supports at the left and right ends and is loaded as shown. Assume P=18 kips, Q=13 kips, L1=4 ft, L2=6 ft, and L3=6 ft. Determine(a) the stresses in all parts of the axial structure.(b) the deflections of joints B and C.
Read the question carefully and give me right solution according to the question.
A W12x79 of A573 Grade 60 (Fy=415 MPa) steel is used as a compression member. It is 8 m long, pinned at the top fixed at the bottom, and has additional support in the weak direction at mid-height. Properties of the section are as follows:
A = 14,500 mm^2
Ix = 258.6 x 10^6 mm^4
Iy = 84.375 x 10^6 mm^4
Calculate the effective slenderness ratio with respect to strong axis buckling using theoretical value of k.
Chapter 4 Solutions
Steel Design (Activate Learning with these NEW titles from Engineering!)
Ch. 4 - Prob. 4.3.1PCh. 4 - Prob. 4.3.2PCh. 4 - Prob. 4.3.3PCh. 4 - Prob. 4.3.4PCh. 4 - Prob. 4.3.5PCh. 4 - Prob. 4.3.6PCh. 4 - Prob. 4.3.7PCh. 4 - Prob. 4.3.8PCh. 4 - Prob. 4.4.1PCh. 4 - Prob. 4.4.2P
Ch. 4 - Prob. 4.6.1PCh. 4 - Prob. 4.6.2PCh. 4 - Prob. 4.6.3PCh. 4 - Prob. 4.6.4PCh. 4 - Prob. 4.6.5PCh. 4 - Prob. 4.6.6PCh. 4 - Prob. 4.6.7PCh. 4 - Prob. 4.6.8PCh. 4 - Prob. 4.6.9PCh. 4 - Prob. 4.7.1PCh. 4 - Prob. 4.7.2PCh. 4 - Prob. 4.7.3PCh. 4 - Use A992 steel and select a W14 shape for an...Ch. 4 - Prob. 4.7.5PCh. 4 - Prob. 4.7.6PCh. 4 - Prob. 4.7.7PCh. 4 - The frame shown in Figure P4.7-8 is unbraced, and...Ch. 4 - Prob. 4.7.9PCh. 4 - Prob. 4.7.10PCh. 4 - Prob. 4.7.11PCh. 4 - Prob. 4.7.12PCh. 4 - Prob. 4.7.13PCh. 4 - Prob. 4.7.14PCh. 4 - Prob. 4.8.1PCh. 4 - Prob. 4.8.2PCh. 4 - Prob. 4.8.3PCh. 4 - Prob. 4.8.4PCh. 4 - Prob. 4.9.1PCh. 4 - Prob. 4.9.2PCh. 4 - Prob. 4.9.3PCh. 4 - Prob. 4.9.4PCh. 4 - Prob. 4.9.5PCh. 4 - Prob. 4.9.6PCh. 4 - Prob. 4.9.7PCh. 4 - Prob. 4.9.8PCh. 4 - Prob. 4.9.9PCh. 4 - Prob. 4.9.10PCh. 4 - Prob. 4.9.11PCh. 4 - Prob. 4.9.12P
Knowledge Booster
Similar questions
- The dimensions of a rectangular beam are limited to b = 300 mm and h = 770 mm. Assume that the bar centroid of tension bars is 70 mm from the beam edge and that of compression bars is 60 mm. Using f’c = 28 MPa, long bar fy = 415 MPa, calculate the following for a factored bending moment of 1200 kN: a. Maximum steel ratio limiting the tensile strain to 0.004. b. Required amount of tensile reinforcement if the tensile steel strain is limited to 0.005. c. Required amount of compression reinforcement.arrow_forwardProb 01: An 18” depth beam is bolted to a 24” depth girder is connected similar to that in figure shown below. Thediameter of the rivet is 20mm and the angles are each 100mm x 100mm x 12mm thick. For each bolt, assume thatthe allowable bearing stress is 220 MPa. Determine the allowable load P in KN on the connection. *show all theload P in kN for bearing stressBeam web thickness = 5mmGirder web thickness =arrow_forwardFind the allowable safe load P if the stresses in the bar are the following :AB=60 ksi BC =50ksi CD=70ksiarrow_forward
- Check the shear strength of an interior beam-column joint. The columns have 20 in. square cross-section, and 12ft clear height. The maximum probable moment strength of columns is (Mpr)ed. 520 ft-kips. The framing beams have the following geometry and reinforcement: Mpr = 345 ft-kips and Mpr = 213 ft-Kips; Top Bar = 5- #8 & Bot. Bar = 3 #8 Additional given data: fe= 4,000 psi; fy=60,000 psiarrow_forwardA square hollow steel strut if thickness 10mm is pin connected to two connector plates of thickness, 12mm. The connector plates are welded to the base plate of thickness, 12mm. The base plate is fastened to te concrete base by 4-16mm diameter anchor bolts. The diameter of the pin is 16mm. Which of the following most nearly gives the shearing stress in the anchor bolts? Choices 150.00 MPa 59.68 MPa 51.69 MPa 119.37 MPaarrow_forwardpls help! Write the complete solutions and legibly. Answer in 2 decimal places. UPVOTE WILL BE GIVEN! MECHANICS OF DEFORMABLE BODIES Let Q = 0 and T = 8 (Example: 12Q°C = 120°C). Just substitute the number in letter. Thank you! For the frame shown, a 4QQT-N load is acting on member ABD at D. If the allowable material shear stress for is 4Q MPa, determine the required diameter (rounded off to the nearest 2.5 mm) of the pins at C and D. Pin C and pin D are subjected to double shear and single shear, respectively. If the thickness of member BC is 12 mm and that of member DE is 16 mm, determine the maximum bearing stress at C.arrow_forward
- A W16x45 (A992 steel) (see below) is used in tension and connected to a plate on each flange. Determine the nominal strength based on the effective area (Ae) two ways: First, use the usual shear lag factor equation U = 1 –(?̅/L). Next use the alternative ‘U’ value from AISC Table D3.1.arrow_forward1. An unsymmetrical flexural member consists of a 70 × 600 topflange, a 70 x 400 bottom flange, and a 12 × 180 web.a, Determine the Section Modulus.b. Determine the distance from the top of the shape to the horizontalplastic neutral axis.c. If A572 Grade 50 steel is used, what is the plastic moment MPy forthe horizontal plastic neutral axis?arrow_forwardAn unsymmetrical flexural member consists of a ½ × 12 top flange, a ½ × 7 bottom flange, and a ⅜ × 16 web. a. Determine the distance y from the top of the shape to the horizontal plastic neutral axis. b. If A572 Grade 50 steel is used, what is the plastic moment M, for the horizontal plastic neutral axis? c. Compute the plastic section modulus Z with respect to the minor principal axis. Pls help!arrow_forward
- f. Calculate the maximum safe load "P" in KN Two A36 16mm Thick Steel Plates Are Connected By Four Rivets With Fv=152 MPa As Shown. Given: Rivet Dia 20 mm x=100 mmarrow_forwardA W 360 x 44 of A992 steel column (Fy =345 MPa) having a length of 4m is fixed at both ends. Compute the effective width, be, of the slender web.Compute the value of reduction factor, Q, due to slender elementsin compression members.Compute the nominal compressive strength of the W-section.Properties of W 360 x 44Ag = 5710 mm2d = 351 mmbf = 171 mmtf = 9.78 mm tw = 6.86 mmkdes = 19.9 mmk1 = 19.1 mmrx = 146 mmry = 37.8 mmarrow_forwardThe hanger is supported using a rectangular pin. Determine the magnitude of the allowable suspended load P if the allowable bearing stress is (σb)allow=220MPa, the allowable tensile stress is (σt)allow=150 MPa, and the allowable shear stress is τallow=130 MPa. Take t=6mm, a=5mm, and b=25mm.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Steel Design (Activate Learning with these NEW ti...Civil EngineeringISBN:9781337094740Author:Segui, William T.Publisher:Cengage Learning
Steel Design (Activate Learning with these NEW ti...
Civil Engineering
ISBN:9781337094740
Author:Segui, William T.
Publisher:Cengage Learning