Question
Chapter 50, Problem 5SQ
To determine
Explain the necessity of opening the disconnect switch in the Figure 50-2 when the machine is not in operation.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
The starter must never operate for more than sixty seconds at a time and should rest for two minutes between extended cranking ? True or false
If an electrical defect occurs in the electronic powersteering(EPS) system, __ .a. the system continues to operate normally, but theEPS warning light is illuminatedb. the system continues to operate with a slightlyreduced power-steering assistc. the EPS control unit shuts the system down byopening the fail-safe and power relaysd. the EPS control unit locks the armature in thesteering gear to prevent armature and screw shaftdamage
Q 127. technician a says a throttle by wire system [ETC] eliminate the need for a cruise control actuator. technician B says ETC also allows the PCM to be more effective when limiting engine and vehicle speed. who is correct?
Chapter 50 Solutions
Electric Motor Control
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
The NEC is very specific in its requirement that submersible electric water pump motors be grounded. Where is this specific requirement found in the Code? _______________________________________________________________________ _______________________________________________________________________
arrow_forward
Using the time limit overload or the dashpot overload relay, how are the following achieved: time-delay characteristics; tripping current adjustments?
arrow_forward
2. In the motor control circuit of Figure 11 in your study unit, the operation of any one of the overload relays has which of the following effects?A. The motor only runs two phases.B. The motor operates normally. C. The auxiliary contact M closes. D. The motor stops
arrow_forward
Worn armature bearing can result in higher than normal starter cranking current draw ? True or false
arrow_forward
Your Answers may be presented through Discussions, Drawings/Figures/Diagrams, Reference to NEC/PEC and Computations
What is the rated full-load current of a ¾-horsepower, 208-volt single-phase motor
arrow_forward
A 3-phase, 15 HP, 230/460-volt motor has a nameplate FLA = 38/19. If operated at 230 volts, ___ amps of current would flow in each motor winding.
Please answer in typing format please ASAP for the like
arrow_forward
Q.35
When overload contacts are connected into a control circuit, are they connected in series with the starter coil or in parallel with the starter coil?
Select one:
A. PARALLEL
B. SERIES
arrow_forward
1-Can a simple variable resistor be used instead of the fan speed regulator? And why?
2-Mention some applications in which such regulators can be used?
3-Can these organizations use to regulate the speed of cooling engines or heating devices? And why?
4-Mention some of the holidays you saw due to the fan speed regulator in your working life? Do you suggest a method to avoid or fix it?
arrow_forward
3 phase , delta connection , 2 pole , 1000 Volt , 50 Hz asynchronous motor 2920 RPM
(friction losses will not be considered)
a) calculate the iron losses of the engine ?
b)calculate the output power of the engine ?
c)calculate the input power ?
d) effiency ?
thank you :)
arrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
Electricity for Refrigeration, Heating, and Air C...
Mechanical Engineering
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Cengage Learning
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Electricity for Refrigeration, Heating, and Air C...
Mechanical Engineering
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Cengage Learning
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT