Automotive Technology: A Systems Approach (MindTap Course List)
6th Edition
ISBN: 9781133612315
Author: Jack Erjavec, Rob Thompson
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Textbook Question
Chapter 55, Problem 10ASRQ
While conducting an A/C system performance test: Technician A inserts a thermometer into the air duct at the center of the dash and monitors discharge temperature. Technician B follows this test with a complete visual inspection. Who is right?
- Technician A only
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Choose correct answer:
ercury does not wet the wall of the tube of thermometer.
Select one:
True
False
What is thermocouple gauge used for detection of leaks in vacuum systems.
HOW TO PERFORM LEAK TEST ON HVAC DUCTS? Badly needed asap. Brief and clear Explanation. I will rate helpful. Thank you.
Chapter 55 Solutions
Automotive Technology: A Systems Approach (MindTap Course List)
Ch. 55 - What should you do if you suspect that an...Ch. 55 - Explain how dye can be used to find leaks in the...Ch. 55 - What is the purpose of the thermostatic switch in...Ch. 55 - Why should the probe of an electronic leak...Ch. 55 - How will air trapped in the A7C system affect...Ch. 55 - Which of the following statements best defines the...Ch. 55 - Which of the following statements is not true...Ch. 55 - To charge an air-conditioning system while it is...Ch. 55 - All of the following are true statements about...Ch. 55 - A very important part of a performance test on an...
Ch. 55 - While conducting a pressure test on an A/C system,...Ch. 55 - The high-side pressure on a system with a cycling...Ch. 55 - When checking an A/C system, the evaporators inlet...Ch. 55 - All of these are good reasons for replacing an...Ch. 55 - In an AZC system, if the low-side pressure is...Ch. 55 - Technician A says that evacuating (pumping down)...Ch. 55 - Technician A says that some refrigerant leaks can...Ch. 55 - Technician A says that the presence of oil around...Ch. 55 - Technician A says that a faulty accumulator will...Ch. 55 - Technician A says that air in the system can cause...Ch. 55 - Technician A feels up and down the face or along...Ch. 55 - Technician A says that a manifold gauge set can be...Ch. 55 - While discussing an inoperative blend air door:...Ch. 55 - Two technicians were discussing how comparing the...Ch. 55 - While conducting an A/C system performance test:...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
Technician A says that a pyrometer measures temperature. Technician B says that a thermometer measures temperature. Who is correct? Technician A Both A and B Technician B Neither A nor B
arrow_forward
Technician A says that a manifold gauge set can be used during the evacuation of the system. Technician B says that a manifold gauge set can be used to diagnose a problem in the A/C system. Who is correct? Technician A only Technician B only Both A and B Neither A nor B
arrow_forward
While discussing a pressure test: Technician A says that a pressure drop of more than 15 psi during a shift indicates a possible leak. Technician B says that any pressure drop between shifts indicates a problem. Who is correct? a. Technician A only b. Technician B only c. Both A and B d. Neither A nor B
arrow_forward
While bleeding air from a cooling system: Technician A loosens a heater hose at its highest point Technician B uses air bleed valves. Who is correct? Technician A Technician B Both A and B Neither A nor B
arrow_forward
While conducting a pressure test on an A/C system, the ambient temperature is 80°F, the low-side gauge reads low (8 psi), and the high side also reads low (85 psi). Which of these could cause these readings? Low refrigerant level Normal operation Bad compressor A high-side restriction
arrow_forward
Technician A says that the presence of oil around a fitting of an air-conditioning line may indicate an oil leak but not a refrigerant leak. Technician B says that using an electronic leak detector is the best way to find the source of a refrigerant leak. Who is correct? Technician A only Technician B only Both A and B Neither A nor B
arrow_forward
True or False? A compression gauge will show the amount of air leaking through a cylinder as a percentage.
arrow_forward
Laser Based Interferometers are used to measure air velocity and pressure.
a.
False
b.
True
arrow_forward
q8
Cleaning a machine with compressed air is a general safety precautions considered while working in a workshop.
Select one:
True
False
arrow_forward
On the low-pressure side of a double diaphragm seal system, the transmitter measures a pressure of 108 in. WC when the tank is empty. Which process should you apply before measuring on the high-pressure side?
Low water level cutoff
Ratholing
Zero suppression
Blowdown
arrow_forward
Q 152. quick tests to a GM hot film mass airflow meter on an engine with idling problems are being performed. technician A taps on the meter lightly with a plastic mallet. technician B unplug the meter. who is correct?
arrow_forward
Mercury does not wet the wall of the tube of thermometer.
Select one:
True
False
arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
Automotive Technology: A Systems Approach (MindTa...
Mechanical Engineering
ISBN:9781133612315
Author:Jack Erjavec, Rob Thompson
Publisher:Cengage Learning
Automotive Technology
Mechanical Engineering
ISBN:9781337794213
Author:ERJAVEC, Jack.
Publisher:Cengage,
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
Automotive Technology: A Systems Approach (MindTa...
Mechanical Engineering
ISBN:9781133612315
Author:Jack Erjavec, Rob Thompson
Publisher:Cengage Learning
Automotive Technology
Mechanical Engineering
ISBN:9781337794213
Author:ERJAVEC, Jack.
Publisher:Cengage,
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
Quality Control and Quality Assurance; Author: AISC Education;https://www.youtube.com/watch?v=C2PFj9YZ_mw;License: Standard Youtube License