Textbook Question
Chapter 55, Problem 10MC
In an AZC system, if the low-side pressure is lower than normal, which of the following is the least likely cause?
- A faulty metering device
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Which of the following statements is false?
The condenser is normally mounted just in front of the radiator.
The receiver/dryer is a storage tank for the liquid refrigerant from the condenser.
An accumulator is not used in any system with a receiver/dryer.
All of the above.
Variable refrigerant flow (VRF) systems modulate the volume of refrigerant that is pumped through the system. This allows?
A. Lower operation cost
B. Better operating efficiencies
C. Matching system capacity to the load
D. All the above
Which of the following statements is true?
Refrigerant leaves the compressor as a high-pressure, high-temperature liquid.
Refrigerant leaves the condenser as a low-pressure, low-temperature liquid.
Refrigerant returns to the compressor as a low-pressure, high-temperature vapor.
None of the above.
Chapter 55 Solutions
Automotive Technology
Ch. 55 - What should you do if you suspect that an...Ch. 55 - Explain how dye can be used to find leaks in the...Ch. 55 - What is the purpose of the thermostatic switch in...Ch. 55 - Why should the probe of an electronic leak...Ch. 55 - How will air trapped in the A7C system affect...Ch. 55 - Which of the following statements best defines the...Ch. 55 - Which of the following statements is not true...Ch. 55 - To charge an air-conditioning system while it is...Ch. 55 - All of the following are true statements about...Ch. 55 - A very important part of a performance test on an...
Ch. 55 - While conducting a pressure test on an A/C system,...Ch. 55 - The high-side pressure on a system with a cycling...Ch. 55 - When checking an A/C system, the evaporators inlet...Ch. 55 - All of these are good reasons for replacing an...Ch. 55 - In an AZC system, if the low-side pressure is...Ch. 55 - Technician A says that evacuating (pumping down)...Ch. 55 - Technician A says that some refrigerant leaks can...Ch. 55 - Technician A says that the presence of oil around...Ch. 55 - Technician A says that a faulty accumulator will...Ch. 55 - Technician A says that air in the system can cause...Ch. 55 - Technician A feels up and down the face or along...Ch. 55 - Technician A says that a manifold gauge set can be...Ch. 55 - While discussing an inoperative blend air door:...Ch. 55 - Two technicians were discussing how comparing the...Ch. 55 - While conducting an A/C system performance test:...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- When checking an A/C system, the evaporators inlet and outlet tubes feel like they are at the same temperature. Which of these could cause this? A plugged evaporator Correct charge of refrigerant in the system Restricted orifice tube Leaking condenserarrow_forwardWhich of the following statements best defines the term evacuation? A process in which the refrigerant in a system is released. A condition that exists when a compressor runs until there is no refrigerant left in the system. The process that pulls all traces of air and moisture from the system. A process that uses air to force moisture and dirt out of the system.arrow_forwardWhile conducting a pressure test on an A/C system, the ambient temperature is 80°F, the low-side gauge reads low (8 psi), and the high side also reads low (85 psi). Which of these could cause these readings? Low refrigerant level Normal operation Bad compressor A high-side restrictionarrow_forward
- Technician A says that air in the system can cause excessive pressure within the system, restricting the refrigerants ability to change its state from gas to liquid within the refrigeration cycle. Technician B says that moisture can cause freeze-up at the cap tube or expansion valve, which restricts refrigerant flow or blocks it completely. Who is correct? Technician A only Technician B only Both A and B Neither A nor Barrow_forwardTechnician A says that some refrigerant leaks can also be traced to pinholes in the evaporator caused by acid, which forms when water and refrigerant mix. Technician B says that leaks are most often found at the compressor hose connections and at the various fittings and joints in the system. Who is correct? Technician A only Technician B only Both A and B Neither A nor Barrow_forwardWhat electrical test instrument is used to measure the current draw of a compressor?arrow_forward
- Which is not a pressure or force acting on a TXV diaphragm? A. Head pressure B. Evaporator pressure C. Spring pressure D. Bulb pressurearrow_forwardTechnician A says that when the A7C system is off, the refrigerant occupies the system as a liquid and its pressure is the same throughout the system. Technician B says that refrigerant is pumped out of the compressor as a high-pressure, high-temperature vapor and is sent to the condenser. Who is correct? Technician A only Technician B only Both A and B Neither A nor Barrow_forwardAir in a refrigeration system causes which of the following problems? A. Acid buildup B. Moisture C. Copper plating D. All of the abovearrow_forward
- The A/C compressor cycles rapidly, and air coming from the vents is only slightly cool. Technician A says the problem could be a low refrigerant charge. Technician B says the problem could be a defective thermostatic switch. Who is right? Group of answer choices Technician A Technician B Both A and B Neither A nor B PreviousNextarrow_forward1) Which of the following is NOT the all air system?A: CAVB: VAVC: Reheat systemD: Fan Coil Unitarrow_forwardWhich of the following statements is not true? A direct acting PRV: Is complex in construction, therefore can malfunction if a very small dirt gets trapped inside the valve, which may result in safety hazard Offers uneven flow Does not provide precise pressure control Causes more wastage of HP compared to a compound one Which of the following basic system components has the primary function of removing the heat of compression from the air? Receiver Relief valve Pressure regulator Dryer Aftercooler Which of the following statements is true? A single acting cylinder may have two ports at two different ends and pressurized fluid can be directed to both of them A single acting cylinder with two ports will can be used as a double acting cylinder A single acting cylinder may have two ports at two different ends but into only one of the ports pressurized fluid is being directed A single acting cylinder…arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Automotive Technology: A Systems Approach (MindTa...Mechanical EngineeringISBN:9781133612315Author:Jack Erjavec, Rob ThompsonPublisher:Cengage LearningRefrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage Learning
Automotive Technology: A Systems Approach (MindTa...
Mechanical Engineering
ISBN:9781133612315
Author:Jack Erjavec, Rob Thompson
Publisher:Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
Thermodynamic Availability, What is?; Author: MechanicaLEi;https://www.youtube.com/watch?v=-04oxjgS99w;License: Standard Youtube License