While conducting a pressure test on an A/C system, the ambient temperature is 80°F, the low-side gauge reads low (8 psi), and the high side also reads low (85 psi). Which of these could cause these readings?
- Low refrigerant level
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
The pressure measured with the help of a pressure gauge is called absolute pressure.
Select one:
True
False
What is thermocouple gauge used for detection of leaks in vacuum systems.
Question1. If an air conditioning system has three independent zones, how many space thermostats will the system have?
Question 2. A technician is traversing a duct and obtains the following 8 velocity: 500fpm, 400fpm, 375fpm,625fpm,275fpm,360fpm,450fpm,and 575fpm. What is the velocity value that can be used for the system calculations?
Chapter 55 Solutions
Automotive Technology
Ch. 55 - What should you do if you suspect that an...Ch. 55 - Explain how dye can be used to find leaks in the...Ch. 55 - What is the purpose of the thermostatic switch in...Ch. 55 - Why should the probe of an electronic leak...Ch. 55 - How will air trapped in the A7C system affect...Ch. 55 - Which of the following statements best defines the...Ch. 55 - Which of the following statements is not true...Ch. 55 - To charge an air-conditioning system while it is...Ch. 55 - All of the following are true statements about...Ch. 55 - A very important part of a performance test on an...
Ch. 55 - While conducting a pressure test on an A/C system,...Ch. 55 - The high-side pressure on a system with a cycling...Ch. 55 - When checking an A/C system, the evaporators inlet...Ch. 55 - All of these are good reasons for replacing an...Ch. 55 - In an AZC system, if the low-side pressure is...Ch. 55 - Technician A says that evacuating (pumping down)...Ch. 55 - Technician A says that some refrigerant leaks can...Ch. 55 - Technician A says that the presence of oil around...Ch. 55 - Technician A says that a faulty accumulator will...Ch. 55 - Technician A says that air in the system can cause...Ch. 55 - Technician A feels up and down the face or along...Ch. 55 - Technician A says that a manifold gauge set can be...Ch. 55 - While discussing an inoperative blend air door:...Ch. 55 - Two technicians were discussing how comparing the...Ch. 55 - While conducting an A/C system performance test:...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- In an AZC system, if the low-side pressure is lower than normal, which of the following is the least likely cause? A faulty metering device Poor airflow across the evaporator A restriction in the low side of the system The system being overcharged with refrigerantarrow_forwardWhich of the following statements about oil gauge circuits is not true? A switch can be used A thermistor can be used. A piezoresistive sensor can be used d An oil pressure gauge may not show actual oil pressure.arrow_forwardWhich of the following statements best defines the term evacuation? A process in which the refrigerant in a system is released. A condition that exists when a compressor runs until there is no refrigerant left in the system. The process that pulls all traces of air and moisture from the system. A process that uses air to force moisture and dirt out of the system.arrow_forward
- True or False: When troubleshooting a small system, the first step is to attach the high- and low-pressure gauges.arrow_forwardBefore installing a gauge on the high-pressure side of a system, you should do which of the following? A. Turn on the system. B. Turn off the system. C. Adjust the system to a neutral position. D. Have a cylinder approved by the DOT nearby.arrow_forwardTwo technicians were discussing how comparing the temperature of a high-pressure line to that of a low- pressure line would help evaluate an A/C system when the system does not have a sight glass. Technician A says that the high-pressure line will feel warmer than the low-pressure line if the system is operating normally. Technician B says that both lines should feel cold after the system has been run for a while if the system is working normally. Who is right? Technician A only Technician B only Both A and B Neither A nor Barrow_forward
- The Fusible plug in a boiler is used to prevent damage to the boiler: OPTIONS: 1.May be 2.False 3.True 4.May not bearrow_forwardWhich of the following statements is not true? A direct acting PRV: Is complex in construction, therefore can malfunction if a very small dirt gets trapped inside the valve, which may result in safety hazard Offers uneven flow Does not provide precise pressure control Causes more wastage of HP compared to a compound one Which of the following basic system components has the primary function of removing the heat of compression from the air? Receiver Relief valve Pressure regulator Dryer Aftercooler Which of the following statements is true? A single acting cylinder may have two ports at two different ends and pressurized fluid can be directed to both of them A single acting cylinder with two ports will can be used as a double acting cylinder A single acting cylinder may have two ports at two different ends but into only one of the ports pressurized fluid is being directed A single acting cylinder…arrow_forwardTechnician A says vacuum refers to any pressure that is greater than atmospheric pressure. Technician B says vacuum changes based on altitude. Who is correct? a. Technician A b. Technician B c. Both A and B d. Neither A nor Barrow_forward
- Which of the following is not a component of a pneumatic system? Group of answer choices An electric motor A pump None of these are true A valve An actuatorarrow_forward1.During a refrigerant system performance test the following results are recorded: outside ambient temperature of 908F, high-side gauge reading of 145 psi, and low pressure gauge reading of 14 psi. What is indicated by these results? A. Faulty refrigerant compressor B. Normal refrigerant system operation C. Low refrigerant levels D. A restriction on the high side of the refrigerant system 2. A customer complains of poor air-conditioning cooling performance. During a system performance test, the low-side gauge reading is 50 psig; the high-side gauge reading is 310 psig; and the ambient air temperature is 818F (27.228C). What is the least likely cause of the above results? A. Restricted airflow through condenser B. Refrigerant overcharge C. Refrigerant undercharge D. Overcharge of refrigerant oil I NEED BOTH QUESTION TYPED ANSWER PLEASE DETAIL ANSWERarrow_forwardChoose correct answer: ercury does not wet the wall of the tube of thermometer. Select one: True Falsearrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Automotive Technology: A Systems Approach (MindTa...Mechanical EngineeringISBN:9781133612315Author:Jack Erjavec, Rob ThompsonPublisher:Cengage LearningRefrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage LearningAutomotive TechnologyMechanical EngineeringISBN:9781337794213Author:ERJAVEC, Jack.Publisher:Cengage,
- Welding: Principles and Applications (MindTap Cou...Mechanical EngineeringISBN:9781305494695Author:Larry JeffusPublisher:Cengage Learning
Automotive Technology: A Systems Approach (MindTa...
Mechanical Engineering
ISBN:9781133612315
Author:Jack Erjavec, Rob Thompson
Publisher:Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
Automotive Technology
Mechanical Engineering
ISBN:9781337794213
Author:ERJAVEC, Jack.
Publisher:Cengage,
Welding: Principles and Applications (MindTap Cou...
Mechanical Engineering
ISBN:9781305494695
Author:Larry Jeffus
Publisher:Cengage Learning
Thermodynamic Availability, What is?; Author: MechanicaLEi;https://www.youtube.com/watch?v=-04oxjgS99w;License: Standard Youtube License