Which of the following statements is not true about orifice tube systems?

  1. The suction line must be cool to the touch from the evaporator outlet to the compressor.

  • The liquid line from the condenser outlet to the evaporator inlet should be cool.
  • The evaporator should feel very cold.
  • The accumulator must be cool to the touch.
  • To determine

    The incorrect statement about orifice tube systems.

    Explanation

    The suction line must always be cool to touch from the evaporator outlet to the compressor.

    The liquid from the condenser outlet to the evaporator inlet must be cool to retain the cooling effect...