Steel Design (Activate Learning with these NEW titles from Engineering!)
Steel Design (Activate Learning with these NEW titles from Engineering!)
6th Edition
ISBN: 9781337094740
Author: Segui, William T.
Publisher: Cengage Learning
Question
Book Icon
Chapter 6, Problem 6.8.6P
To determine

(a)

The best suitable W shape of A992 steel on the basis of load resistance and factor design.

Expert Solution
Check Mark

Answer to Problem 6.8.6P

The best suitable W shape of A992 steel is on the basis of load resistance and factor design is W12×79.

Explanation of Solution

Given:

The axial load is 92kips.

The length of the column is 16ft.

The moment at top in x-direction is 160ft-kips.

The moment at top in y-direction is 24ft-kips.

The moment at bottom in x-direction is 214ft-kips.

The moment at bottom in y-direction is 31ft-kips.

Calculation:

Write the equation to obtain the load factor.

Pu=1.2PD+1.6PL ..... (I)

Here, load factor is Pu, axial live load is PL and axial dead load is PD.

Substitute (92/2)kips for PL as 50% is the live load given and (92/2)kips for PD as 50% is the dead load in Equation (I).

Pu=1.2(922kips)+1.6(922kips)=55.2kips+73.6kips=128.8kips

Write the equation to obtain factored bending moment at the bottom of the member for braced condition along x-axis.

Mnbx=1.2MDbx+1.6MLbx ..... (II)

Here, factored bending moment at bottom along x-axis is Mnbx, bending moment due to live load at bottom along x-axis is MLbx, and the bending moment due to dead load at bottom along x-axis is MLbx.

Substitute (160/2)ft-kips for MLb as 50% of the load is live load, and (160/2)ft-kips for MDb as 50% of the load is dead load in Equation (II).

Mnbx=1.2(1602ft-kips)+1.6(1602ft-kips)=96ft-kips+128ft-kips=224ft-kips

Write the equation to obtain factored bending moment at the top of the member for braced condition along x-axis.

Mntx=1.2MDtx+1.6MLtx ..... (III)

Here, factored bending moment at top along x-axis is Mntx, bending moment due to live load at top along x-axis is MLtx, and the bending moment due to dead load at top along x-axis is MLtx.

Substitute (214/2)ft-kips for MLtx as 50% of the load is live load, and (214/2)ft-kips for MDtx as 50% of the load is dead load in Equation (III).

Mntx=1.2(2142ft-kips)+1.6(2142ft-kips)=128.4ft-kips+171.2ft-kips=299.6ft-kips

Write the equation to obtain factored bending moment at the bottom of the member for braced condition along y-axis.

Mnby=1.2MDby+1.6MLby ..... (IV)

Here, factored bending moment at bottom along y-axis is Mnby, bending moment due to live load at bottom along y-axis is MLby, and the bending moment due to dead load at bottom along y-axis is MLby.

Substitute (24/2)ft-kips for MLb as 50% of the load is live load and (24/2)ft-kips for MDb as 50% of the load is dead load in Equation (IV).

Mnby=1.2(242ft-kips)+1.6(242ft-kips)=14.4ft-kips+19.2ft-kips=33.6ft-kips

Write the equation to obtain factored bending moment at the top of the member for braced condition along y-axis.

Mnty=1.2MDty+1.6MLty ..... (V)

Here, factored bending moment at top along y-axis is Mnty, bending moment due to live load at top along y-axis is MLty, and the bending moment due to dead load at top along y-axis is MLty.

Substitute (31/2)ft-kips for MLty as 50% of the load is live load and (31/2)ft-kips for MDty as 50% of the load is dead load in Equation (V).

Mnty=1.2(312ft-kips)+1.6(312ft-kips)=18.6ft-kips+24.8ft-kips=43.4ft-kips

Write the equation to obtain the ultimate moment along x-axis.

Mux=B1Mntx+B2Mnbx ..... (VI)

Here, factor for braced condition is B1, factor for side sway condition is B2.

Substitute 1 for B1, 299.6ft-kips for Mntx, 0 for B2 and 224ft-kips for Mnbx in Equation (VI).

Mux=(1)(299.6ft-kips)+(0)(224ft-kips)=299.6ft-kips

Write the equation to obtain the ultimate moment along y-axis.

Muy=B1Mnty+B2Mnby ..... (VII)

Here, factor for braced condition is B1, factor for side sway condition is B2.

Substitute 1 for B1, 43.4ft-kips for Mnty, 0 for B2 and 33.6ft-kips for Mnby in Equation (VII).

Mux=(1)(43.4ft-kips)+(0)(33.6ft-kips)=43.4ft-kips

The unbraced length and effective length of the member are same.

Lb=kL=16ft

Try W10×100 ; from table 6-2, ϕcPn=900.9kips, ϕbMnx=460.56ft-kips and ϕbMny=228.5ft-kips.

Write the expression to determine which interaction equation to use.

PuϕcPn>0.2 ..... (VIII)

Here, load factor is Pu and the factor which deals with the axial strength of member is ϕcPn.

Substitute 128.8kips for Pu and 900.9kips for ϕcPn in Equation (VIII).

128.8kips900.9kips0.142<0.2

Therefore, AISC equation H1-1a. Controls.

Write the expression AISC equation H1-1a.

0.5PuϕcPn+89(MuxϕbMnx+MuyϕbMny) ..... (IX)

Here, load factor is Pu and the factor which deals with the axial strength of member is ϕcPn, moment factor in x-direction is ϕbMnx, moment factor in y-direction is ϕbMny, ultimate moment in x direction is Mux, and ultimate moment in y-direction is Muy.

Substitute 128.8kips for Pu, 900.9kips for ϕcPn, 299.4ft-kips for Mux, 460.56ft-kips for ϕbMnx, 43.4ft.kips for Muy and 228.5ft-kips for ϕbMny in Equation (IX).

0.5×128.8kips900.9kips+89(299.4ft-kips460.56ft-kips+43.4ft-kips228.5ft-kips)0.0714+89(0.65+0.189)0.0714+89(0.839)0.0714+0.745

Further solve the above equation.

0.816<1

Hence it is safe to use W10×100.

Try W12×79, from table 6-2, ϕcPn=781.25kips, ϕbMnx=416.13ft-kips and ϕbMny=203.4ft-kips.

Write the expression to determine the interaction equation to be used.

PuϕcPn>0.2 ..... (X)

Here, load factor is Pu and the factor which deals with the axial strength of member is ϕcPn.

Substitute 128.8kips for Pu and 781.25kips for ϕcPn in Equation (X).

128.8kips781.25kips0.1648<0.2

Therefore, AISC equation H1-1a. controls.

Write the expression AISC equation H1-1a.

0.5PuϕcPn+89(MuxϕbMnx+MuyϕbMny) ..... (XI)

Here, load factor is Pu and the factor which deals with the axial strength of member is ϕcPn, moment factor in x-direction is ϕbMnx, moment factor in y-direction is ϕbMny, ultimate moment in x direction is Mux, and ultimate moment in y-direction is Muy.

Substitute 128.8kips for Pu, 781.25kips for ϕcPn, 299.4ft-kips for Mux, 416.13ft-kips for ϕbMnx, 43.4ft.kips for Muy and 203.4ft-kips for ϕbMny in Equation (XI).

0.5×128.8kips781.25kips+89(299.4ft-kips416.13ft-kips+43.4ft-kips203.4ft-kips)0.0824+89(0.719+0.213)0.0824+89(0.932)0.0824+0.828

Further solve the above equation.

0.910<1

Hence, it is safe to use W12×79.

Try W14×82, from table 6-2, ϕcPn=694.44kips, ϕbMnx=460.56ft-kips and ϕbMny=228.5ft-kips.

Write the expression to determine which interaction equation to use.

PuϕcPn>0.2 ..... (XII)

Here, load factor is Pu and the factor which deals with the axial strength of member is ϕcPn.

Substitute 128.8kips for Pu and 694.44kips for ϕcPn in Equation (XII).

128.8kips694.44kips0.1854<0.2

Therefore, AISC equation H1-1a. controls.

Write the expression AISC equation H1-1a.

0.5PuϕcPn+89(MuxϕbMnx+MuyϕbMny) ..... (XIII)

Here, load factor is Pu and the factor which deals with the axial strength of member is ϕcPn, moment factor in x-direction is ϕbMnx, moment factor in y-direction is ϕbMny, ultimate moment in x direction is Mux, and ultimate moment in y-direction is Muy.

Substitute 128.8kips for Pu, 694.44kips for ϕcPn, 299.4ft-kips for Mux, 462.96ft-kips for ϕbMnx, 43.4ft.kips for Muy and 168.03ft-kips for ϕbMny in Equation (XIII).

0.5×128.8kips694.44kips+89(299.4ft-kips462.96ft-kips+43.4ft-kips168.03ft-kips)0.0927+89(0.6467+0.258)0.0927+89(0.9049)0.0927+0.8043

Further solve the above equation.

0.897<1

Hence, it is safe to use W14×82.

Further check W12×79 as it is lightest among all, from table 6-2, ϕcPn=781.25kips, ϕbMnx=416.13ft-kips and ϕbMny=203.4ft-kips for final check.

Write the expression AISC equation H1-1a.

0.5PuϕcPn+89(MuxϕbMnx+MuyϕbMny) ..... (XIV)

Here, load factor is Pu and the factor which deals with the axial strength of member is ϕcPn, moment factor in x-direction is ϕbMnx, moment factor in y-direction is ϕbMny, ultimate moment in x direction is Mux and ultimate moment in y-direction is Muy.

Substitute 128.8kips for Pu, 781.25kips for ϕcPn, 299.4ft-kips for Mux, 446.67ft-kips for ϕbMnx, 43.4ft.kips for Muy, and 203.4ft-kips for ϕbMny in Equation (XIV).

0.5×128.8kips781.25kips+89(299.4ft-kips403.4ft-kips+43.4ft-kips203.4ft-kips)0.0824+89(0.7421+0.213)0.0824+89(0.9551)0.0824+0.849

Further solve the above equation.

0.931<1

Hence, it is safe to use W12×79.

Conclusion:

Thus, use W12×79.

To determine

(b)

The best suitable W shape of A992 steel on the basis of Allowed Stress Design.

Expert Solution
Check Mark

Answer to Problem 6.8.6P

The best suitable W shape of A992 steel on the basis of Allowed Stress Design is W12×79.

Explanation of Solution

Calculation:

Write the equation to obtain the axial service load.

Pu=PD+PL ..... (XV)

Here, load factor is Pu, axial live load is PL and axial dead load is PD.

Substitute (92/2)kips for PL as 50% is the live load given and (92/2)kips for PD as 50% is the dead load in Equation (XV).

Pu=(922kips)+(922kips)=46kips+46kips=92kips

Write the equation to obtain factored bending moment at the bottom of the member for braced condition along x-axis.

Mnbx=MDbx+MLbx ..... (XVI)

Here, factored bending moment at bottom along x-axis is Mnbx, bending moment due to live load at bottom along x-axis is MLbx, and the bending moment due to dead load at bottom along x-axis is MLbx.

Substitute (160/2)ft-kips for MLb as 50% of the load is live load and (160/2)ft-kips for MDb as 50% of the load is dead load in Equation (XVI).

Mnbx=(1602ft-kips)+(1602ft-kips)=80ft-kips+80ft-kips=160ft-kips

Write the equation to obtain factored bending moment at the top of the member for braced condition along x-axis.

Mntx=MDtx+MLtx ..... (XVII)

Here, factored bending moment at top along x-axis is Mntx, bending moment due to live load at top along x-axis is MLtx, and the bending moment due to dead load at top along x-axis is MLtx.

Substitute (214/2)ft-kips for MLtx as 50% of the load is live load and (214/2)ft-kips for MDtx as 50% of the load is dead load in Equation (XVII).

Mntx=(2142ft-kips)+(2142ft-kips)=107ft-kips+107ft-kips=214ft-kips

Write the equation to obtain factored bending moment at the bottom of the member for braced condition along y-axis.

Mnby=MDby+MLby ..... (XVIII)

Here, factored bending moment at bottom along y-axis is Mnby, bending moment due to live load at bottom along y-axis is MLby, and the bending moment due to dead load at bottom along y-axis is MLby.

Substitute (24/2)ft-kips for MLb as 50% of the load is live load and (24/2)ft-kips for MDb as 50% of the load is dead load in Equation (XVIII).

Mnby=(242ft-kips)+(242ft-kips)=12ft-kips+12ft-kips=24ft-kips

Write the equation to obtain factored bending moment at the top of the member for braced condition along y-axis.

Mnty=MDty+MLty ..... (XIX)

Here, factored bending moment at top along y-axis is Mnty, bending moment due to live load at top along y-axis is MLty, and the bending moment due to dead load at top along y-axis is MLty.

Substitute (31/2)ft-kips for MLty as 50% of the load is live load and (31/2)ft-kips for MDty as 50% of the load is dead load in Equation (XIX).

Mnty=(312ft-kips)+(312ft-kips)=15.5ft-kips+15.5ft-kips=31ft-kips

Write the equation to obtain the ultimate moment along x-axis.

Mux=B1Mntx+B2Mnbx ..... (XX)

Here, factor for braced condition is B1, factor for side sway condition is B2.

Substitute 1 for B1, 214ft-kips for Mnt, 0 for B2 and 160ft-kips for Mnb in Equation (XX).

Mux=(1)(214ft-kips)+(0)(160ft-kips)=214ft-kips

Write the equation to obtain the ultimate moment along y-axis.

Muy=B1Mnty+B2Mnby ..... (XXI)

Here, factor for braced condition is B1, factor for side sway condition is B2.

Substitute 1 for B1, 31ft-kips for Mnt, 0 for B2 and 24ft-kips for Mnb in Equation (XXI).

Mux=(1)(31ft-kips)+(0)(24ft-kips)=31ft-kips

The unbraced length and effective length of the member are the same.

Lb=kL=16ft

Try W10×100, from table 6-2, Pn/Ωc=598.8kips, Mnx/Ωb=306.51ft-kips and Mnx/Ωb=152.2ft-kips.

Write the expression to determine the interaction equation to be used.

PuPn/Ωc>0.2 ..... (XXII)

Here, load factor is Pu and the factor which deals with the axial strength of member is Pn/Ωc.

Substitute 92kips for Pu and 598.8kips for Pn/Ωc in Equation (XXII).

92kips598.8kips0.153<0.2

Therefore, AISC equation H1-1a. controls.

Write the expression AISC equation H1-1a.

0.5PuPn/Ωc+89(MuxMnx/Ωb+MuyMny/Ωb) ..... (XXIII)

Here, load factor is Pu and the factor which deals with the axial strength of member is Pn/Ωc, moment factor in x-direction is Mnx/Ωb, moment factor in y-direction is Mny/Ωb, ultimate moment in x direction is Mux, and ultimate moment in y-direction is Muy.

Substitute 92kips for Pu, 598.8kips for Pn/Ωc, 214ft-kips for Mux, 306.51ft-kips for Mnx/Ωb, 31ft.kips for Muy and 152.2ft-kips for Mny/Ωb in Equation (XXIII).

0.5×92kips598.8kips+89(214ft-kips306.51ft-kips+31ft-kips152.2ft-kips)0.0768+89(0.6981+0.2036)0.0768+89(0.9017)0.0768+0.8015

Further solve the above equation.

0.878<1

Hence, it is safe to use W10×100.

Try W12×79, from table 6-2, Pn/Ωc=520.83kips, Mnx/Ωb=306.51ft-kips and Mnx/Ωb=135.5ft-kips.

Write the expression to determine which interaction equation to use.

PuPn/Ωc>0.2 ..... (XXIV)

Here, load factor is Pu and the factor which deals with the axial strength of member is Pn/Ωc.

Substitute 92kips for Pu and 520.83kips for Pn/Ωc in Equation (XXIV).

92kips520.83kips0.176<0.2

Therefore, AISC equation H1-1a. controls.

Write the expression AISC equation H1-1a.

0.5PuPn/Ωc+89(MuxMnx/Ωb+MuyMny/Ωb) ..... (XXV)

Here, load factor is Pu and the factor which deals with the axial strength of member is Pn/Ωc, moment factor in x-direction is Mnx/Ωb, moment factor in y-direction is Mny/Ωb, ultimate moment in x direction is Mux, and ultimate moment in y-direction is Muy.

Substitute 92kips for Pu, 520.83kips for Pn/Ωc, 214ft-kips for Mux, 306.51ft-kips for Mnx/Ωb, 31ft.kips for Muy and 135.50ft-kips for Mny/Ωb in Equation (XXV).

0.5×92kips520.83kips+89(214ft-kips306.51ft-kips+31ft-kips135.50ft-kips)0.0883+89(0.6981+0.2287)0.0883+89(0.9017)0.0883+0.8015

Further solve the above equation.

0.8898<1

Hence, it is safe to use W12×79.

Try W14×82, from table 6-2, Pn/Ωc=462.96kips, Mnx/Ωb=307.57ft-kips and Mnx/Ωb=111.80ft-kips.

Write the expression to determine which interaction equation to use.

PuPn/Ωc>0.2 ..... (XXVI)

Here, load factor is Pu and the factor which deals with the axial strength of member is Pn/Ωc.

Substitute 92kips for Pu and 462.96kips for Pn/Ωc in Equation (XXVI).

92kips492.96kips0.1866<0.2

Therefore, AISC equation H1-1a. controls.

Write the expression AISC equation H1-1a.

0.5PuPn/Ωc+89(MuxMnx/Ωb+MuyMny/Ωb) ..... (XXVII)

Here, load factor is Pu and the factor which deals with the axial strength of member is Pn/Ωc, moment factor in x-direction is Mnx/Ωb, moment factor in y-direction is Mny/Ωb, ultimate moment in x direction is Mux, and ultimate moment in y-direction is Muy.

Substitute 92kips for Pu, 492.96kips for Pn/Ωc, 214ft-kips for Mux, 307.57ft-kips for Mnx/Ωb, 31ft.kips for Muy, and 111.80ft-kips for Mny/Ωb in Equation (XXVII).

0.5×92kips492.96kips+89(214ft-kips307.57ft-kips+31ft-kips111.80ft-kips)0.0933+89(0.695+0.2772)0.0933+89(0.9722)0.0933+0.8641

Further solve the above equation.

0.9574<1

Hence, it is safe to use W14×82.

Further check W12×79 as it lightest among all, from table 6-2, Pn/Ωc=520.83kips, Mnx/Ωb=347.221ft-kips, and Mnx/Ωb=111.80ft-kips.

Write the expression AISC equation H1-1a.

0.5PuPn/Ωc+89(MuxMnx/Ωb+MuyMny/Ωb) ..... (XXVIII)

Here, load factor is Pu and the factor which deals with the axial strength of member is Pn/Ωc, moment factor in x-direction is Mnx/Ωb, moment factor in y-direction is Mny/Ωb, ultimate moment in x direction is Mux, and ultimate moment in y-direction is Muy.

Substitute 92kips for Pu, 520.83kips for Pn/Ωc, 214ft-kips for Mux, 347.22ft-kips for Mnx/Ωb, 31ft.kips for Muy, and 111.80ft-kips for Mny/Ωb in Equation (XXVIII).

0.5×92kips520.83kips+89(214ft-kips347.221ft-kips+31ft-kips111.80ft-kips)0.0883+89(0.6163+0.2772)0.0883+89(0.8935)0.0883+0.7942

Further solve the above equation.

0.8825<1

Hence, it is safe to use W12×79.

Conclusion:

Thus, use W12×79.

Want to see more full solutions like this?

Subscribe now to access step-by-step solutions to millions of textbook problems written by subject matter experts!
Students have asked these similar questions
The beam-column in the figure below is a member of a braced frame. A second-order analysis was performed with factored loads and reduced member stiffnesses to obtain the moments and axial force shown. Use LRFDand determine whether this member is adequate. Suppose that P = 165 kFor W10 x 60 with L, = 15 ft and C6 = 1.0: ф,M, = 257 ft-kips, ф,M, = 280 ft-kips;for Lc = 15 ft: cPr = 556 kips.
A W12x79 of A573 Grade 60 (Fy = 415 MPa) steel is used as a compression member.  It is 6.6 m long, fixed at the top and bottom, and has additional support in the weak direction at mid-height.  Properties of the section are as follows:          A = 14,500 mm^2         Ix = 258.6 x 10^6 mm^4         Iy = 84.375 x 10^6 mm^4 Calculate the effective slenderness ratio with respect to strong axis buckling using theoretical value of k.
A W12x79 of A573 Grade 60 (Fy = 415 MPa) steel is used as a compression member.  It is 6.8 m long, fixed at the top and bottom, and has additional support in the weak direction at mid-height.  Properties of the section are as follows:          A = 14,500 mm^2         Ix = 258.6 x 10^6 mm^4         Iy = 84.375 x 10^6 mm^4 Calculate the critical slenderness ratio with respect to weak axis buckling using theoretical value of k.
Knowledge Booster