Textbook Question
Chapter 60, Problem 5SQ
Refer to the circuit shown in Figure 60–16. The motor will not start in either the forward or reverse direction when the start push buttons are pressed. Which of the following could not cause this problem?
- a. The F coil is open.
- b. The overload contact is open.
- c. The control transformer fuse is blown.
- d. The stop push button is not making a complete circuit.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
8.a. What is the purpose of relay CRE in the roll stand machine?A. Relay CRE is used as an emergency stop relay.B. Relay CRE is used to control an alarm light.C. Relay CRE is used to power the PLC.D. Relay CRE is used to power the input modules.
8.b. Which one of the following statements is true of a disabled contact or coil?A. The disabled element has been automatically disabled due to module failure.B. The disabled element is held false by the PLC.C. A disabled contact or coil is caused by a faulty memory location in the PLC.D. A contact must be in the disabled state before it can be forced ON or OFF.
A 460VAC rated, 60 Hz, 125-Hp Three-phase induction type motor is to be connected for across-the-line starting. The nameplate indicates the motor’s maximum ampere rating, 160A. It has a NEMA code letter B. The ambient temp of the installation place is and TW copper will be used. Short-circuit protection device that will be used is Inverse Time Breaker.
Calculate the Thermal Overload Protection.
If an electrical defect occurs in the electronic powersteering(EPS) system, __ .a. the system continues to operate normally, but theEPS warning light is illuminatedb. the system continues to operate with a slightlyreduced power-steering assistc. the EPS control unit shuts the system down byopening the fail-safe and power relaysd. the EPS control unit locks the armature in thesteering gear to prevent armature and screw shaftdamage
Chapter 60 Solutions
Electric Motor Control
Ch. 60 - What are the three main electrical test...Ch. 60 - What is the advantage of a plunger-type voltage...Ch. 60 - A motor is tripping out on overload. The motor...Ch. 60 - A motor is tripping out on overload. The motor...Ch. 60 - Refer to the circuit shown in Figure 6016. The...Ch. 60 - Refer to the circuit shown in Figure 6016. Assume...Ch. 60 - Prob. 7SQCh. 60 - Prob. 8SQCh. 60 - Refer to the circuit shown in Figure 6016. If a...Ch. 60 - Prob. 10SQ
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Select the best answer for each of the following. If an operator pushes a start button on a three-phase induction motor and the motor starts to hum, but not run, the probable trouble is a. one fuse is blown and the motor is single phasing. b. the overload trip needs resetting. c. the auxiliary contact is shorted. d. one phase is grounded.arrow_forwardRefer to the circuit shown in Figure 105. Assume that the motor is running and an overload occurs, which causes the OL contact to open and disconnect coil M to stop the motor. What effect does the opening of the overload contact have on the pressure switch circuit?arrow_forwardA squirrel-cage induction motor has a nameplate full-load current of 78 amperes and a marked temperature rise of 30C. The motor requires a NEMA size 4 starter. Using the overload heater chart in Figure 34-8, what size overload heaters should be used to protect this motor?arrow_forward
- A 460VAC rated, 60 Hz, 125-Hp Three-phase induction type motor is to be connected for across-the-line starting. The nameplate indicates the motor’s maximum ampere rating, 160A. It has a NEMA code letter B. The ambient temp of the installation place is and TW copper will be used. Short-circuit protection device that will be used is Inverse Time Breaker. Calculate the Branch Circuit Protection.arrow_forwardA 460VAC rated, 60 Hz, 125-Hp Three-phase induction type motor is to be connected for across-the-line starting. The nameplate indicates the motor’s maximum ampere rating, 160A. It has a NEMA code letter B. The ambient temp of the installation place is and TW copper will be used. Short-circuit protection device that will be used is Inverse Time Breaker. Calculate the Motor Starter Size.arrow_forwardA 460VAC rated, 60 Hz, 125-Hp Three-phase induction type motor is to be connected for across-the-line starting. The nameplate indicates the motor’s maximum ampere rating, 160A. It has a NEMA code letter B. The ambient temp of the installation place is and TW copper will be used. Short-circuit protection device that will be used is Inverse Time Breaker. Calculate the Conductor size.arrow_forward
- Technician A says when testing the voltage output, if the charging voltage is too high, the cause could be an open field wire from the regulator. Technician B says a loose or glazed drive belt could be the cause of too high charging voltage. Who is correct? A only B only Both A and B Neither A or B Technician A says that poor connection at the generator output wire can cause charging systems problems. Technician B says that many charging system circuits contain a circuit protection device. Who is correct? A only B only Both A and B Neither A or Barrow_forwardD.b- A DC motor will normally require that you replace which one of the following components on a regularschedule?A. BrushesB. ArmaturesC. GearsD. BearingsD.c- You're doing a PM inspection on a small chain-drive system. You see one side of the sprockets is shinywhile the opposite side is dull. This means that theA. chain is the wrong size.B. sprockets are worn.C. chain is worn.D. sprockets are misaligned.arrow_forwardINCounter-Current Breaking of a 3-Phase Induction Motor (Reversing the Operation of a 3-Phase Induction Motor). Could you suggest any improvements to the control circuit?arrow_forward
- At standstill condition, the back emf is zero, so the motor can be safely turned ON without a starter. Select one: OTrue O Falsearrow_forwardIf the full load current of a three-phase motor is 40 Amperes, the size of the circuit breaker is a. 100 AT c. 300AT b. 120 AT d. 80 AT A 50-hp, 440-volt, 3-phase, 1750 rpm, SCRIM, how many pair of poles a. 4 c. 3 b. 2 d. 1 The required rated voltage applied to a six leads out motor are a. 760-volts and 440-volts c. 440-volts and 254-volts b. 220-volts and 127-volts d. All of the abovearrow_forwardA starter turns very slowly and has excessive cranking current draw. When removed from the vehicle and bench tested, the starter spins normally and current draw is within specifications. Technician A says poor battery connections may be the cause. Technician B says an internal engine problem may be the cause. Who is correct?arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Delmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage LearningElectricity for Refrigeration, Heating, and Air C...Mechanical EngineeringISBN:9781337399128Author:Russell E. SmithPublisher:Cengage Learning
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning
Electricity for Refrigeration, Heating, and Air C...
Mechanical Engineering
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Cengage Learning
FMPR-103 pt1 l Power Systems Protection v1; Author: L&D for Protection and Control;https://www.youtube.com/watch?v=ELWncjsh5uE;License: Standard Youtube License