To determine

Find the time required to increase the oil temperature from 20°C to 100°C.

Expert Solution & Answer
Check Mark

Answer to Problem 1P

The time required to increase the oil temperature from 20°C to 100°C is 14.7sec¯.

Explanation of Solution

Given information:

The width of the parabolic trough l is 1.0m.

The insider diameter of the pipe d is 1cm.

Initial temperature T1 is 20°C  and the final temperature T2 is 100°C.

Calculation:

Take the mid day irradiance of incident radiation as 674W/m2 and incident power of the 1 m long parabolic trough P as 674 W.

The inside diameter of the pipe is 1 cm.

Find the volume of oil in a 1 m pipe section V.

V=π4d2×l=π41cm2×1m=π41cm×102m1cm2×1m=7.85×105m3

Take the density of oil ρ as 900kg/m3 and the value of specific heat C as 1,758J/kg°C.

Express the formula for energy Q as follows:

Q=mCΔT                                                                                                                   …... (1)

Here, the mass is m and the change in temperature is ΔT.

Write the expression for power P as follows:

P=QtQ=Pt

Here, t is the time required to raise the oil temperature.

The mass is the product of density and the volume. Therefore, m=ρV.

Substitute Pt for Q and ρV for m in equation (1).

Pt=ρVCΔTt=ρVCT2T1Pt=900kg/m3×7.85×105m3×1,758J/kg°C×100°C20°C674W

t=14.7sec

Therefore, the time required to raise the oil temperature is 14.7sec¯.

Want to see more full solutions like this?

Subscribe now to access step-by-step solutions to millions of textbook problems written by subject matter experts!
Students have asked these similar questions
A 2 x 2 m flat plate solar collector for domestic hot water heating is shown in the figure. The incident solar radiation on the glass cover, which transmits 90% of the incident flux, is 750 W/m2. Water flows through the tubes soldered to the backside of the absorber plate, entering at a temperature of 25°C. The temperature of the glass cover is 27°C, and it radiates heat with an emissivity of 0.92 to the sky at –50°C. Additionally, the glass cover losses heat by convection to air at 20°C flowing over its surface at 30 km/h. Assume that the radiation heat transfer between the absorber plate and glass cover and the heat transfer through the back and sides of the collector is negligible.
Civil Engineering Using the gray atmosphere model with an emissivity of 0.77 and a assuming a constant observed mean July surface temperature of 22 ◦C, plot the net downward longwave radiation over the course of the day. Plot the net downward radiative flux at Rochester’s latitude (43°) over the course of the day. When would the radiation flux lead to surface warming and when would it lead to surface cooling? What is the daily mean flux, and would this lead to warming or cooling?
Polarizing windows, filters, etc. are often used to reduce the amount of light that enters the lens of a camera or into a room or a car. A library atrium has an overhead skylight that lets in too much light during the day which heats up the interior of the library far too much. The building engineer installs new double paned polarizing sky lights to reduce the intensity. If sunlight, which is unpolarized, has an average intensity of 1364 W/m2 what angle should the polarizing axis of the second pane of the window make with the polarizing axis of the first pane of the window in order to reduce the intensity of the sunlight to 35% of the original value?
Knowledge Booster
Background pattern image
Similar questions
Recommended textbooks for you
Text book image
Sustainable Energy
Civil Engineering
ISBN:9781337551663
Author:DUNLAP, Richard A.
Publisher:Cengage,
Text book image
Engineering Fundamentals: An Introduction to Engi...
Civil Engineering
ISBN:9781305084766
Author:Saeed Moaveni
Publisher:Cengage Learning