Ion exchange

Page 1 of 50 - About 500 essays
  • Lab #3: Ion Exchange Chromatography

    1233 Words  | 5 Pages

    Lab #3: Ion Exchange Chromatography Objective The purpose of this experiment was to separate proteins on the basis of their net charge at a particular pH. In cation exchange chromatography positively charged molecules are attracted to a negatively charged column. Conversely, in anion exchange chromatography, negatively charged molecules are attracted to a positively charged column. Experimental results could be monitored in a predictable way by controlling running pH, salt concentration, and by

  • Ion Exchange Chromatography Lab Report

    537 Words  | 3 Pages

    1. Ion exchange chromatography is a technique, which separates a mixture of amino acids based on their produced charge. Isoelectric point is a pH where the given amino acid has a no charge thus; produces a neutral structure. With a pH above the isoelectric point will cause the amino acid to be deprotonated and thus; produce a negative charge where as a pH lower than the isoelectric point will cause the amino acid to be protonated and thus; hold a positive charge. 2. In the experiment a cation exchange

  • Water Pollution

    1164 Words  | 5 Pages

    Additionally, once the zeolite molecular sieve columns are saturated with radium, the resulting solid radioactive waste must be disposed of because the radium binds too tightly to the zeolite and cannot be removed for future use in energy or heat production. Thus, this method still produces radioactive waste, which has reached a total of one million tons in just one year.17 Because the solid waste produced exceeds radioactive material soil application and landfill limits, this waste must be disposed

  • Advantages And Disadvantages Of Vinylimidazole

    1163 Words  | 5 Pages

    obtained after drying in a vacuum oven at 40 °C for 1d. 1H-NMR (PAEK-NHS, DMSO-d6): 7.02 (H-1), 7.85 (H-2), 7.04 (H-3), 7.32 (H-4), 1.62 (H-5); 2.45 (H-6), 2.01 (H-7), 2.85 (H-8). 1.2 Synthesis of PAEK-g-[PBVIm-I] and preparation alkaline anion exchange membrane (PAEK-g-[PBVIm-OH]) PAEK-g-[PBVIm-I] was synthesized from 0.01 mole of PAEK-NHS and the excess amount of PBVIm-I (0.015 mole) as shown in Fig. 1B. PAEK-NHS and PBVIm-I were dissolved in DMAc and stirred at room temperature for 1 d

  • The System : A Scale Up Study Done By Fei Zhang Et Al Essay

    1564 Words  | 7 Pages

    application would most likely be based on the use of multiple modules connected together instead of one large reactor, the MDC module in this study was made up of 30 individual tubular MDCs. Each MDC consists of one anion exchange membrane (AEM) tube inside the cation exchange membrane (CEM) tube. Two ways of parallel connections of the MDC were investigated. One way was via combined connection whereby all the anodes or cathodes are connected to form one anode or cathode (total 1

  • Essay The Glegg Water Management

    820 Words  | 4 Pages

    Technology: As mentioned in the material, traditionally, caustic chemicals were used to flush away the impurities and regenerate these resins. In these systems, the mixed-bed ion-exchange stage was preceded by separate cation and anion exchange vessels. As applications became more demanding, it was clear that chemically regenerated ion exchange systems had limitations. ”

  • Primary Care Testing For Cancer Cell By Ion Exchange .

    1184 Words  | 5 Pages

    Primary Care Testing for Cancer Cell by Ion Exchange For people with concerns about health issues, the physician 's office is usually the first contact with healthcare. Physician’s waiting room is usually busy with patients of all ages with different symptoms and reasons for being there. With a physician’s competence and medical experience, they know what can be easily cured, what should be followed up, and what needs to be referred to a specialist. The accurate testing of clinical parameters is

  • Column Chromatography Lab

    2156 Words  | 9 Pages

    2016 Partner: Megumi Mori GSI: Erin Experiment #8: Quantitative Analysis of a Solution Containing Cobalt and Copper I. Abstract: II. Introduction: This experiment will help students to get familiar with Ion Exchange Chromatography (IEC) which is used mostly to separate unknown mixture of metal ions. Anion and cation are known as two types of IEC. This column chromatography contains two phase such as stationary phase and mobile phase. In this experiment, stationary phase usually is made of organic

  • Magnetic Properties Essay

    1301 Words  | 6 Pages

    only atoms bound to metal ions. Colour scheme as in Figure 2. Magnetic Properties The magnetic properties of compounds 1 – 4 were measured on polycrystalline samples dispersed in eicosane. The phase purity of the samples was demonstrated by powder X-ray diffraction (see Figures S9 – S12 in the SI). Fig. 5 shows the temperature dependence of χMT for 1 – 4. The values of χMT at 280 K are 12.1; 15.1; 18.6; 18.3 cm3 mol−1 K (1; 2; 3; 4), consistent with four uncoupled Mn(III) ions (S = 2, g = 2, χMTcalc

  • Clo2 Residual Testing Method

    2145 Words  | 9 Pages

    Björkholm et al. 1990; Hekmat et al. 1994 (OSHA Method 202) Hoehn et al. 2000 (EPA Method 300.0) Pfaff and Brockhoff 1990 No data APHA 1998 (Method 4500CLO2-D) Diffusion of air into potasIon chromatosium iodide solution at pH 7. graphy (of chlorite ion

Previous
Page12345678950