A feeder-selector device at one of the stations of an automated assembly machine has a feed rate of 25 parts per minute and provides a throughput of one part in four. The ideal cycle time of the assembly machine is 10 sec. The low level sensor on the feed track is set at 10 parts, and the high level sensor is set at 20 parts. How long will it take for the supply of parts to be depleted from the high level sensor to the low level sensor once the feeder-selector device is turned off? How long will it take for the parts to be resupplied from the low level sensor to the high level sensor, on average, after the feeder-selector device is turned on? What proportion of the time that the assembly machine is operating will the feeder-selector device be turned on? Turned off?
A feeder-selector device at one of the stations of an automated assembly machine has a feed rate of 25 parts per minute and provides a throughput of one part in four. The ideal cycle time of the assembly machine is 10 sec. The low level sensor on the feed track is set at 10 parts, and the high level sensor is set at 20 parts. How long will it take for the supply of parts to be depleted from the high level sensor to the low level sensor once the feeder-selector device is turned off? How long will it take for the parts to be resupplied from the low level sensor to the high level sensor, on average, after the feeder-selector device is turned on? What proportion of the time that the assembly machine is operating will the feeder-selector device be turned on? Turned off?
Electricity for Refrigeration, Heating, and Air Conditioning (MindTap Course List)
10th Edition
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Russell E. Smith
Chapter13: Heating Control Devices
Section: Chapter Questions
Problem 30RQ
Related questions
Question
A feeder-selector device at one of the stations of an automated assembly machine has a feed rate of 25 parts per minute and provides a throughput of one part in four. The ideal cycle time of the assembly machine is 10 sec. The low level sensor on the feed track is set at 10 parts, and the high level sensor is set at 20 parts.
- How long will it take for the supply of parts to be depleted from the high level sensor to the low level sensor once the feeder-selector device is turned off?
- How long will it take for the parts to be resupplied from the low level sensor to the high level sensor, on average, after the feeder-selector device is turned on?
- What proportion of the time that the assembly machine is operating will the feeder-selector device be turned on? Turned off?
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution!
Trending now
This is a popular solution!
Step by step
Solved in 3 steps
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning