An aerated lagoon (a sewage treatment pond that is mixed with air) is being proposed for a small lake com- munity in northern Wisconsin. The lagoon must be designed for the summer population but will operate year-round. The winter population is about half of the summer population. Based on these design assump- tions, the volume of the proposed lagoon is 3420 m³. The daily volume of sewage in the winter is estimated to be 300 m³. In January, the temperature of the lagoon drops to 0°C but it is not yet frozen. If the temperature of the wastewater flowing into the lagoon is 15°C, estimate the temperature of the lagoon at the end of a day. Assume the lagoon is completely mixed and that there are no losses to the atmosphere or the lagoon walls or floor. Also assume that the sewage has a density of 1000 kg m and a specific heat of 4.186 kJ kg K-¹

Sustainable Energy
2nd Edition
ISBN:9781337551663
Author:DUNLAP, Richard A.
Publisher:DUNLAP, Richard A.
Chapter14: Ocean Thermal Energy Conversion And Ocean Salinity Gradient Energy
Section: Chapter Questions
Problem 14P
icon
Related questions
icon
Concept explainers
Question
An acrated lagoon (a sewage treatment pond that is mixed with air) is being proposed for a small lake com-
munity in northern Wisconsin. The lagoon must be designed for the summer population but will operate
year-round. The winter population is about half of the summer population. Based on these design assump-
tions, the volume of the proposed lagoon is 3420 m³. The daily volume of sewage in the winter is estimated
to be 300 m³. In January, the temperature of the lagoon drops to 0°C but it is not yet frozen. If the temperature
of the wastewater flowing into the lagoon is 15°C, estimate the temperature of the lagoon at the end of a day.
Assume the lagoon is completely mixed and that there are no losses to the atmosphere or the lagoon walls or
floor. Also assume that the sewage has a density of 1000 kg m and a specific heat of 4.186 kJ kg K-¹
Transcribed Image Text:An acrated lagoon (a sewage treatment pond that is mixed with air) is being proposed for a small lake com- munity in northern Wisconsin. The lagoon must be designed for the summer population but will operate year-round. The winter population is about half of the summer population. Based on these design assump- tions, the volume of the proposed lagoon is 3420 m³. The daily volume of sewage in the winter is estimated to be 300 m³. In January, the temperature of the lagoon drops to 0°C but it is not yet frozen. If the temperature of the wastewater flowing into the lagoon is 15°C, estimate the temperature of the lagoon at the end of a day. Assume the lagoon is completely mixed and that there are no losses to the atmosphere or the lagoon walls or floor. Also assume that the sewage has a density of 1000 kg m and a specific heat of 4.186 kJ kg K-¹
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps with 3 images

Blurred answer
Knowledge Booster
Integrated solid waste management
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,