Transcribed Image Text:Heparin is used as an anti-coagulant. A risk of heparin use is thrombocytopenia, or low platelet
count. This risk is minimized with the use of low molecular weight heparins (LMWH), therefore it is
desirable to separate LMWH from higher molecular weight heparins. The method of choice to do
this is molecular exclusion chromatography. Below is a chromatogram from a molecular exclusion
chromatographic run. Peaks ranging from A to J are clearly distinguishable. The heparin mixture
that was analyzed had anywhere from 6 to 30 repeat units of monomer (where the heparin with 30
repeat units would be roughly five times the size of the heparin with six repeat units).
a. Which letter most likely represents the peak with 6 repeat units given these heparin polymers
were separated with molecular exclusion chromatography?
b. Explain your reasoning describing the mechanism of retention in molecular exclusion
chromatography.
100
80
60
60
Relative Abundance
40
40
E
GH
20
20
B
A
36 38 40 42 44 46 48 50
50
52
2
54 56 58 60
axis label on bottom is retention time (minutes)
60
Expert Solution

This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by stepSolved in 2 steps

Knowledge Booster
Similar questions
- 1a) Hexane, CH3(CH2)4CH3, is found to have a long retention time when separated from a mixture. A column with a C18 (18-carbon chain) stationary phase and a methanol-water modal phase is used for the separation. Explain why hexane has a long retention time. 1b)You wish to chromatographically seperate a mixtureof the follwing compunds. Which of the two compounds will be most difficult to seperatate from one another? Why?arrow_forward2-pentanone has a retention index of 987 on a poly(ethylene glycol) column (also called Carbowax). (a) Between which two straight-chain hydrocarbons is 2-pentanone eluted? (b) An unretained solute is eluted from a certain column in 1.80 min. Decane (C10H22) is eluted in 15.63 min and undecane (C11H24) is eluted in 17.22 min. What is the retention time of a compound whose retention index is 1 050?arrow_forwardIn normal-phase HPLC chromatography, the stationary phase is polar and the mobile phase is nonpolar. In the reversed phase we have just the opposite; the stationary phase is nonpolar and the mobile phase is polar. Describe molecules in which move faster or slower in each case.arrow_forward
- Iman has a mixture of two compounds A and B. A is a protein, and B is a lipid. He plans to separate the mixture using a column chromatography technique. He packed the column with amino bonded with siloxane material and use a mixture of 20:80 of water: hexane as the mobile phase. i) Sketch the apparatus set up for the chromatographic technique used by Iman. Use the correct chromatographic terminologies to label all of the apparatus, materials, and phases. ii) Predict the sequence of elution when the mixture was loaded onto the separation column. Justify your answer. iii) After the first compound was eluted, Iman discovered that the second compound was taking too long to pass through the column. Please suggest any strategies that could be used to aid the elution process.arrow_forwardPlease propose a chromatography-based strategy to purify human insulin proteins that have been expressed in bacterial cells.arrow_forwardColumn Chromatography Alumina Chromatography Mixture 9:1 Hexanes:Ether 8:2 Hexanes:Ether 1:1 Hexanes:Acetone Amount Used 3.962 g 0.143 g 9.50 mL 9.50 mL 11.00 mL Additional Observations (Color, etc.) BIU X₂ X² → BI IU X₂ X² → BI IU X₂ X² → BI IU X₂ X² → BIU X₂ X² →arrow_forward
- 1) Study the chromatograph (below) of a mixture of Compounds A and B, run on the GCs in the teaching labs at CU Boulder. Compound A has the shorter retention time. STAAT 61 1.11 227 RT TYPE AREA XXXX XXXX XXXX AREAS 0.009 55874 44.117 ARIHT 0.61 XX XX XX 1.11 2.27 XX XX XX TOTAL AREA=XX MUL FACTOR=XX 1. What is the retention time of compound A? Compound B? 2. Which compound is present in a larger amount? 3. Which compound has the lower boiling point? 4. What would happen to the retention times of compounds A and B if the column temperature were raised? 5. You suspect that compound B is octane. What can you do to provide supporting evidence for this hypothesis?arrow_forwardWhich of the following types of liquid chromatography uses immobilized biochemical as a stationary phase? affinity chromatography ion exchange chromatography gel permeation chromatography exclusion chromatographyarrow_forwardIn molecular exclusion (size exclusion) chromatography, the molecules have the longest retention times. a) the larger molecules b) the smaller moleculesarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK A SMALL SCALE APPROACH TO ORGANIC LChemistryISBN:9781305446021Author:LampmanPublisher:CENGAGE LEARNING - CONSIGNMENTPrinciples of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage Learning

EBK A SMALL SCALE APPROACH TO ORGANIC L
Chemistry
ISBN:9781305446021
Author:Lampman
Publisher:CENGAGE LEARNING - CONSIGNMENT

Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning