Wet air out Water in Air in Air in Water out An cooling tower (see the figure above) is used to cool water from 110 to 80°F. Water enters the tower at a rate of 117639 kg/h. Dry air (no water vapor) flows into the tower at a rate of 66674 kg/h. If the rate of wet airflow out of the tower is 74424 kg/h, determine the rate of cooled water flow in kg/h.
Wet air out Water in Air in Air in Water out An cooling tower (see the figure above) is used to cool water from 110 to 80°F. Water enters the tower at a rate of 117639 kg/h. Dry air (no water vapor) flows into the tower at a rate of 66674 kg/h. If the rate of wet airflow out of the tower is 74424 kg/h, determine the rate of cooled water flow in kg/h.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
Related questions
Question
![0.1
0.09A
Wholly turbu lent flow
0.08-
0.07-
0.05
0.04
0.06-
0.03
0.05-
0.02
0.015
0.04
0.01
0.008
0.006
0.03 -
0.004
D
0.025-
0.002
0.02-
0.001
0.0008
0.0006
Laminar
flow
0.0004
0.015-
Smooth
0.0002
Transition range
0.0001
0.00005
0.01
0.009-
0.008
0.00001
2(10)
4 6 8
2(10)
4 6 8
2(10)
4 6
8.
2(10)
4
6 8
2(10')
4
6 8
10
104
105
10
107
Re = e VD](/v2/_next/image?url=https%3A%2F%2Fcontent.bartleby.com%2Fqna-images%2Fquestion%2F85ed0eb4-61da-4d1a-9c74-a52e23182a03%2F84dd53a6-1146-48d2-bfb5-b486e06f3120%2Fu1e5obi_processed.jpeg&w=3840&q=75)
Transcribed Image Text:0.1
0.09A
Wholly turbu lent flow
0.08-
0.07-
0.05
0.04
0.06-
0.03
0.05-
0.02
0.015
0.04
0.01
0.008
0.006
0.03 -
0.004
D
0.025-
0.002
0.02-
0.001
0.0008
0.0006
Laminar
flow
0.0004
0.015-
Smooth
0.0002
Transition range
0.0001
0.00005
0.01
0.009-
0.008
0.00001
2(10)
4 6 8
2(10)
4 6 8
2(10)
4 6
8.
2(10)
4
6 8
2(10')
4
6 8
10
104
105
10
107
Re = e VD
![Wet
air out
Water in
A^^^
Air in
Air in
Water out
An cooling tower (see the figure above) is used to cool water from 110 to 80°F. Water enters the tower at a rate of
117639 kg/h. Dry air (no water vapor) flows into the tower at a rate of 66674 kg/h. If the rate of wet airflow out of the
tower is 74424 kg/h, determine the rate of cooled water flow in kg/h.
Answer:](/v2/_next/image?url=https%3A%2F%2Fcontent.bartleby.com%2Fqna-images%2Fquestion%2F85ed0eb4-61da-4d1a-9c74-a52e23182a03%2F84dd53a6-1146-48d2-bfb5-b486e06f3120%2Fdczg6ue_processed.jpeg&w=3840&q=75)
Transcribed Image Text:Wet
air out
Water in
A^^^
Air in
Air in
Water out
An cooling tower (see the figure above) is used to cool water from 110 to 80°F. Water enters the tower at a rate of
117639 kg/h. Dry air (no water vapor) flows into the tower at a rate of 66674 kg/h. If the rate of wet airflow out of the
tower is 74424 kg/h, determine the rate of cooled water flow in kg/h.
Answer:
Expert Solution
![](/static/compass_v2/shared-icons/check-mark.png)
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 2 steps
![Blurred answer](/static/compass_v2/solution-images/blurred-answer.jpg)
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
![Structural Analysis](https://compass-isbn-assets.s3.amazonaws.com/isbn_cover_images/9781337630931/9781337630931_smallCoverImage.jpg)
![Structural Analysis (10th Edition)](https://www.bartleby.com/isbn_cover_images/9780134610672/9780134610672_smallCoverImage.gif)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
![Principles of Foundation Engineering (MindTap Cou…](https://www.bartleby.com/isbn_cover_images/9781337705028/9781337705028_smallCoverImage.gif)
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
![Structural Analysis](https://compass-isbn-assets.s3.amazonaws.com/isbn_cover_images/9781337630931/9781337630931_smallCoverImage.jpg)
![Structural Analysis (10th Edition)](https://www.bartleby.com/isbn_cover_images/9780134610672/9780134610672_smallCoverImage.gif)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
![Principles of Foundation Engineering (MindTap Cou…](https://www.bartleby.com/isbn_cover_images/9781337705028/9781337705028_smallCoverImage.gif)
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
![Fundamentals of Structural Analysis](https://www.bartleby.com/isbn_cover_images/9780073398006/9780073398006_smallCoverImage.gif)
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
![Sustainable Energy](https://www.bartleby.com/isbn_cover_images/9781337551663/9781337551663_smallCoverImage.gif)
![Traffic and Highway Engineering](https://www.bartleby.com/isbn_cover_images/9781305156241/9781305156241_smallCoverImage.jpg)
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning