1- Some HV - TL use Double Circuit .instead of One, why To transmit maximum voltage stability, and enhance the steady state stability. O To increase the capacity of HVTL and to enhance power system stability. a- C- All these answers are wrong. d- To increase the impedance of HVTL and to enhance power system stability. Sometimes we use Red Balls with HV T in snecific location

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter6: Power Flows
Section: Chapter Questions
Problem 6.47P
icon
Related questions
icon
Concept explainers
Question
1- Some HV - TL use Double Circuit .instead of One, why
To transmit maximum voltage stability, and enhance the steady state stability.
6 To increase the capacity of HVTL and to enhance power system stability.
a-
All these answers are wrong.
d- To increase the impedance of HVTL and to enhance power system stability.
2- Sometimes we use Red Balls with HV.TL in specific locations ? why and where
a- To prevent HV.TL from lightning, it located at earth wire over roads and rivers.
To give an alarm for the planes, it located at earth wire over roads and rivers.
To reduce static transient voltage, it located at earth wire over roads and rivers.
d- To reduce static transient voltage, it located at earth wire everywhere.
3- How you can read this impulse voltage : 1.2/50 us and at which ? Standard
Durations wave front : 1.2 tr, Wave tail duration is defined as 50 m.si as in
International Standard).
C Durations wave front : 1.2 tr ( where tr is the transient time ), Wave tail
duration is defined as 50 m.s ( as in International Standard).
d- Durations wave front : 1.2 tr, Wave tail duration is defined as 50 m.s ( as in
British Standard ).
e- All these answer are wrong.
4- if we have a power system of 1 pu volt at sending busbar and 0.9 pu at receiving end
busbar with Xd = 0.45 pu, determine the allowable transfer power that the system
will not lose stability , also determine the maximum power transfer , take .the base
MVA = 500 MVA
The allowable transfer power = 500 MVA Max power = 1000 MVA.
b- The allowable transfer power = 2000 MVA Max power 1000 MVA.
C- The allowable transfer power = 1000 MVA Max power = 1000 MVA.
d- The allowable transfer power = 500 MVA , Max power = 500 MVA
5- Back inverse voltage value (Vbin) is an important factor in design DC High Voltage.
C-
C-
b-
Generator
a- because it is the most important factor in design consideration.
b- Because the cost is increased as ( Vbin ) increased.
C- Because it is related to space and size of DC High Voltage Generator.
d- All these reasons are right.
6- If the nominal ( L-G) voltage is 76.21 kv, the maximum ( L-L): voltage will be
a- 186.67 kv.
b- 131.999 kv.
C- 145.2 kv.
d- 93.33 kv
7- If we have a multi - stage impulse generator with a highest charging voltage (Vmax)
of 200KV & a discharge capacitance of the generator ( Cg) of 1 microfarad. If we
need to generate a high voltage of 7.07107 MV (r.m.s): 1) What is the number of
stages? 2) What is the ? energy of this generator
a- 4 stage, 200 KJ.
b- All these answers are wrong.
C- 5 stage, 200 KJ.
d-50 stage, 20KJ
8- B.I.L must be less than B.P.L by .25%
a- Right.
b-
Wrong
Transcribed Image Text:1- Some HV - TL use Double Circuit .instead of One, why To transmit maximum voltage stability, and enhance the steady state stability. 6 To increase the capacity of HVTL and to enhance power system stability. a- All these answers are wrong. d- To increase the impedance of HVTL and to enhance power system stability. 2- Sometimes we use Red Balls with HV.TL in specific locations ? why and where a- To prevent HV.TL from lightning, it located at earth wire over roads and rivers. To give an alarm for the planes, it located at earth wire over roads and rivers. To reduce static transient voltage, it located at earth wire over roads and rivers. d- To reduce static transient voltage, it located at earth wire everywhere. 3- How you can read this impulse voltage : 1.2/50 us and at which ? Standard Durations wave front : 1.2 tr, Wave tail duration is defined as 50 m.si as in International Standard). C Durations wave front : 1.2 tr ( where tr is the transient time ), Wave tail duration is defined as 50 m.s ( as in International Standard). d- Durations wave front : 1.2 tr, Wave tail duration is defined as 50 m.s ( as in British Standard ). e- All these answer are wrong. 4- if we have a power system of 1 pu volt at sending busbar and 0.9 pu at receiving end busbar with Xd = 0.45 pu, determine the allowable transfer power that the system will not lose stability , also determine the maximum power transfer , take .the base MVA = 500 MVA The allowable transfer power = 500 MVA Max power = 1000 MVA. b- The allowable transfer power = 2000 MVA Max power 1000 MVA. C- The allowable transfer power = 1000 MVA Max power = 1000 MVA. d- The allowable transfer power = 500 MVA , Max power = 500 MVA 5- Back inverse voltage value (Vbin) is an important factor in design DC High Voltage. C- C- b- Generator a- because it is the most important factor in design consideration. b- Because the cost is increased as ( Vbin ) increased. C- Because it is related to space and size of DC High Voltage Generator. d- All these reasons are right. 6- If the nominal ( L-G) voltage is 76.21 kv, the maximum ( L-L): voltage will be a- 186.67 kv. b- 131.999 kv. C- 145.2 kv. d- 93.33 kv 7- If we have a multi - stage impulse generator with a highest charging voltage (Vmax) of 200KV & a discharge capacitance of the generator ( Cg) of 1 microfarad. If we need to generate a high voltage of 7.07107 MV (r.m.s): 1) What is the number of stages? 2) What is the ? energy of this generator a- 4 stage, 200 KJ. b- All these answers are wrong. C- 5 stage, 200 KJ. d-50 stage, 20KJ 8- B.I.L must be less than B.P.L by .25% a- Right. b- Wrong
Expert Solution
steps

Step by step

Solved in 3 steps with 1 images

Blurred answer
Knowledge Booster
Load flow analysis
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning