13-3 A refrigerant 22 refrigerating system operates with a condensing temperature of 35°C and an evaporating temperature of -10°C. If the vapor leaves the evaporator saturated and is compressed isentropically, what is the COP of the cycle (a) if saturated liquid enters the expansion device and (b) if the refrigerant entering the expansion de- vice is 10 percent vapor as in Fig. 13-3? Ans. (a) 4.71, (b) 4.20 13-4 Refrigerant 22 at a pressure of 1500 kPa leaves the condenser and rises vertically

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter22: Condensers
Section: Chapter Questions
Problem 7RQ: When a standard-efficiency air-cooled condenser is used, the condensing refrigerant will normally be...
icon
Related questions
Question

Subject: Refrigeration Systems
Course: Mechanical Engineering
Reference Book : Stoecker and Jones, Refrigeration and Air Conditioning

13-3 A refrigerant 22 refrigerating system operates with a condensing temperature of
35°C and an evaporating temperature of -10°C. If the vapor leaves the evaporator
saturated and is compressed isentropically, what is the COP of the cycle (a) if saturated
liquid enters the expansion device and (b) if the refrigerant entering the expansion de-
vice is 10 percent vapor as in Fig. 13-3? Ans. (a) 4.71, (b) 4.20
13-4 Refrigerant 22 at a pressure of 1500 kPa leaves the condenser and rises vertically
10 m to the expansion valve. The pressure drop due to friction in the liquid line is
20 kPa. In order to have no vapor in the refrigerant entering the expansion valve, what
is the maximum allowable temperature at that point? Ans. 35.3°C
Transcribed Image Text:13-3 A refrigerant 22 refrigerating system operates with a condensing temperature of 35°C and an evaporating temperature of -10°C. If the vapor leaves the evaporator saturated and is compressed isentropically, what is the COP of the cycle (a) if saturated liquid enters the expansion device and (b) if the refrigerant entering the expansion de- vice is 10 percent vapor as in Fig. 13-3? Ans. (a) 4.71, (b) 4.20 13-4 Refrigerant 22 at a pressure of 1500 kPa leaves the condenser and rises vertically 10 m to the expansion valve. The pressure drop due to friction in the liquid line is 20 kPa. In order to have no vapor in the refrigerant entering the expansion valve, what is the maximum allowable temperature at that point? Ans. 35.3°C
Expert Solution
steps

Step by step

Solved in 3 steps with 3 images

Blurred answer
Knowledge Booster
Refrigeration and Air Conditioning
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning
Principles of Heat Transfer (Activate Learning wi…
Principles of Heat Transfer (Activate Learning wi…
Mechanical Engineering
ISBN:
9781305387102
Author:
Kreith, Frank; Manglik, Raj M.
Publisher:
Cengage Learning