2. In the counter flow heat exchanger, the water at 20°C is used to cool the liquid from 80°C to 30°C, and the volumetric flow rate of the liquid is 5.3m³/h, the specific heat of the liquid is 1.9kJ/ (kg. C), its density is 850kg/m³. The pipe diameter of the exchanger is $25×2.5mm., and the water flows in the tube-side. The individual heat transfer coefficients of the water-side and the liquid-side are 0.85kW/ (m². C) and 1.70kW/(m². C), respectively. The thermal conductivity km of the pipe is 45W/(m. C). Neglecting the scale resistance of pipe wall. If the outlet temperature of the water cannot be over 50°C, calculate the heat transfer surface area of the exchanger.<

Principles of Heat Transfer (Activate Learning with these NEW titles from Engineering!)
8th Edition
ISBN:9781305387102
Author:Kreith, Frank; Manglik, Raj M.
Publisher:Kreith, Frank; Manglik, Raj M.
Chapter10: Heat Exchangers
Section: Chapter Questions
Problem 10.1P: 10.1 In a heat exchanger, as shown in the accompanying figure, air flows over brass tubes of 1.8-cm...
icon
Related questions
Question
5
2. In the counter flow heat exchanger, the water at 20°C is used to cool the
liquid from 80°C to 30°C, and the volumetric flow rate of the liquid is
5.3m³/h, the specific heat of the liquid is 1.9kJ/ (kg. C), its density is
850kg/m³. The pipe diameter of the exchanger is $25×2.5mm., and the
water flows in the tube-side. The individual heat transfer coefficients of the
water-side and the liquid-side are 0.85kW/ (m².C) and 1.70kW/(m².
C), respectively. The thermal conductivity km of the pipe is 45W/(m. C).
Neglecting the scale resistance of pipe wall. If the outlet temperature of the
water cannot be over 50 °C, calculate the heat transfer surface area of the
exchanger.
Transcribed Image Text:2. In the counter flow heat exchanger, the water at 20°C is used to cool the liquid from 80°C to 30°C, and the volumetric flow rate of the liquid is 5.3m³/h, the specific heat of the liquid is 1.9kJ/ (kg. C), its density is 850kg/m³. The pipe diameter of the exchanger is $25×2.5mm., and the water flows in the tube-side. The individual heat transfer coefficients of the water-side and the liquid-side are 0.85kW/ (m².C) and 1.70kW/(m². C), respectively. The thermal conductivity km of the pipe is 45W/(m. C). Neglecting the scale resistance of pipe wall. If the outlet temperature of the water cannot be over 50 °C, calculate the heat transfer surface area of the exchanger.
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Basic Mechanics Problems
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Principles of Heat Transfer (Activate Learning wi…
Principles of Heat Transfer (Activate Learning wi…
Mechanical Engineering
ISBN:
9781305387102
Author:
Kreith, Frank; Manglik, Raj M.
Publisher:
Cengage Learning
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning