3. A REVERSED CARNOT CYCLE IS USED FOR REFRIGERATION AND REJECTS 200 000 Btu/min OF HEAT AT 152.6F WHILE RECEIVING HEAT AT 450.6R. DETERMINE THE COP, THE POWER REQUIRED IN KJ/min AND THE REFRIGERATING CAPACITY IN TR.

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter35: Comfort And Psychrometrics
Section: Chapter Questions
Problem 12RQ: A gas furnace has an output of 60,000 Btu/h. The return air temperature is 72F, and the temperature...
icon
Related questions
Question

Answer 3problems

1. A REFRIGERATING SYSTEM OPERATES A REVERSED CARNOT CYCLE BETWEEN
TEMPERATURES OF 15F AND 128F. IF THE CAPACITY IS 420 000 Btu/hr. DETERMINE THE
COP, HEAT REJECTED FROM THE SYSTEM IN kcal/min, THE NET WORK IN Kw, AND THE
НР.
2. A REFRIGERATING SYSTEM OPERTES ON THE REVERSED CARNOT CYCLE WITH A COP OF 4
AND A MINIMUM TEMPERATURE OF 27C. IF THE REFRIGERATING CAPACITY IS 6000
KJ/min, DETERMINE THE MAXIMUM TEMPERATURE IN THE CYCLE, THE HEAT REJECTED
AND THE POWER INPUT REQUIRED.
3. A REVERSED CARNOT CYCLE IS USED FOR REFRIGERATION AND REJECTS 200 000 Btu/min
OF HEAT AT 152.6F WHILE RECEIVING HEAT AT 450.6R. DETERMINE THE COP, THE POWER
REQUIRED IN KJ/min AND THE REFRIGERATING CAPACITY IN TR.
Transcribed Image Text:1. A REFRIGERATING SYSTEM OPERATES A REVERSED CARNOT CYCLE BETWEEN TEMPERATURES OF 15F AND 128F. IF THE CAPACITY IS 420 000 Btu/hr. DETERMINE THE COP, HEAT REJECTED FROM THE SYSTEM IN kcal/min, THE NET WORK IN Kw, AND THE НР. 2. A REFRIGERATING SYSTEM OPERTES ON THE REVERSED CARNOT CYCLE WITH A COP OF 4 AND A MINIMUM TEMPERATURE OF 27C. IF THE REFRIGERATING CAPACITY IS 6000 KJ/min, DETERMINE THE MAXIMUM TEMPERATURE IN THE CYCLE, THE HEAT REJECTED AND THE POWER INPUT REQUIRED. 3. A REVERSED CARNOT CYCLE IS USED FOR REFRIGERATION AND REJECTS 200 000 Btu/min OF HEAT AT 152.6F WHILE RECEIVING HEAT AT 450.6R. DETERMINE THE COP, THE POWER REQUIRED IN KJ/min AND THE REFRIGERATING CAPACITY IN TR.
Expert Solution
steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Knowledge Booster
Fluid Kinematics
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning