Q: Can Type TW cable be used in an area that has an ambient temperature of 65degreesC?
A: IN the NEC table of standard cables, it is given the correction factors for the TW cable at…
Q: Short circuit test is used for what type of losses?
A:
Q: calculate the current carrying capacity of cable protected by fuse with 60 A ,the first half of the…
A:
Q: Hi. What kind of connector used by the Plenum cable? What is the example of Plenum cable. Thanks…
A:
Q: 3.a. Which type of equipment is used to bridge sections of horizontal, backbone, or patch cable? A.…
A: The portion of the optical power that does not pass through the splice and is radiated out of the…
Q: A long, inexpensive extension cord is connected from inside the house to a refrigerator outside. The…
A: The resistance of the extension cord depends on, R=ρlA Here, ρ is the resistivity of the cord, lis…
Q: The reactance value obtained in the idle test is the sum of which circuit parameters in the…
A: During Idle test, No load test or open circuit test the core losses of the machine are calculated.…
Q: 10.C-Which part of the NEC standard proposes the switches requirements? D-If the branch circuits…
A: The Given General living space is
Q: What is the 277-volt–single-phase–60-hertz system used for? Select one: A. RECEPTACLE BRANCH…
A: 277-volt–single-phase–60-hertz system has the voltage of 277 volt- and frequency of 60 hertz it is…
Q: 2. What fault occurs when Line and Neutral wires come with each other? Which device is actuated?
A: According to the given question, it is required to describe the fault which occurs when a line and a…
Q: what is the largest size overcurrent protection device (fuse or breaker) allowed to protect the…
A: Concept: The circuit which is used to electrically describe and model either continuous materials or…
Q: A single-phased load is located 2800 ft from its source. The load draws a current of 86 A and…
A: Maximum voltage drop is 3% Edrop=480×3100=14.4 V So maximum allowed resistance is…
Q: what wire size is needed on a one 20 amp, 120-volt bathroom circuit? what wire size is needed on a…
A: Proper wire size is an important fact to be considered in any of the electrical wiring installation.…
Q: Most residential general lighting circuits are wired with 14-AWG copper conductors and are protected…
A: Generally, the electricians follow the table wherein the calculated values of circuit breaker size…
Q: Table 314.16(A) of the Code shows the maximum number of conductors permitted in a given size box. In…
A: When setting a job, an electrician often makes a circuit, thinking of the best way to use wires…
Q: What is the largest voltage drop in the wires that is allowed by the code?
A: As per the NEC keeping in mind about the performance issue. The NEC recommends the largest voltage…
Q: what wire size is needed on a one 20 amp, 120-volt water pump circuit?
A: Cable size for to carry 20 amp, 120v
Q: Short circuit test measure half load copper loss. True or False
A: The explanation is as follows.
Q: What screw size is use to secure a lighting outlet ?
A:
Q: If a fuel line is routed through a compartment parallel with an electrical wire bundle, the fuel…
A:
Q: The motor takes 3 HP at an efficiency of 2%. The voltage at the terminals of the motor is 110 volts.…
A: Given: η=0.02P0= 3×746=2238 WV =110 V
Q: Please answer all questions and give me a sample answers, 1- What determines the ampacity of a…
A: Since we answer only first question out of all given by student, we’ll answer the first .Please…
Q: What device can determine how far a cable damage is
A: Cable faults are defined as an unacceptable characteristic or performance of the cable utilized in…
Q: 0.2. Find and mention the type of cable for the given example/ applications in the table below. (#…
A: Telephone and modem lines Classification of cable: Insulated copper wire is used. Type of cable:…
Q: Calculations show that a particular circuit should be protected for a current of 315a. You would use…
A: It is said that a particular circuit should be protected for a current of 315 A. We need to tell the…
Q: Q6) Explain by drawing a block diagram of a power supply?
A: Draw the block diagram of the Regulated power supply.
Q: Differentiate cable tester with multi meter.
A: A cable tester is an electronic device used to check the electrical connections in a signal cable or…
Q: what wire size is needed on a one 30 amp, 120/240-volt electric clothes dryer branch circuit? what…
A: The proper selection of wire size is an important factor to be considered in any electrical wiring…
Q: What device is used to insert power onto the coaxial cable for powering amplifiers and nodes? Line…
A: As per bartleby guideline for more than one question asked only first is to be answered please…
Q: What's the maximum number of 400 kcmil THHN conductors that can be installed in a 6 in. x 6 in.…
A: Given 400 Kcmil conductors Size of wire way = 6 in.× 6 in.
Q: what wire size is needed for a one 20-amp, 240-volt water pump
A:
Q: A key provision found in most of the cable articles states that the cable must not be installed…
A: Where subject to physical damage, conductors, Raceways, and cables shall be protected.
Q: The short-circuit and open-circuit tests were performed high-voltage rating of 7600 volts and…
A:
Q: Draw the primary protection zones for each element of the system in the figure shown.
A: We have to draw the primary protection zones for the given power system shown below:
Q: 19.b. In a DC system, the bonding jumper between the negative of the supply and ground is normally…
A: Given that In a DC system, the bonding jumper between the negative of the supply and ground is…
Q: What is the voltage and maximum current that can be used on the three cable types to power DeviceNet…
A: DeviceNet DeviceNet is a network protocol used in the automation sector to connect and share data…
Q: New dishwasher circuits can be wired directly to NM cable. The circuit breaker is the disconnect. O…
A: NM Cable- NM cables is a type of cable in which the two or more insulated wires are again covered in…
Q: 20.a. What's the maximum number of switches or circuit breakers the service-disconnecting means may…
A:
Q: a) Draw the schematic diagram of LVDT. Explain the operation of the same.
A: As per Bartleby guidelines, we are allowed to only solve one question please ask the rest again.…
Q: Write all information about cable of extra super voltage?
A:
Q: Which type of equipment is used to bridge sections of horizontal, backbone, or patch cable? A.…
A:
Q: Determine the power provided by the 20-volt source in the circuit below. Indicate if the 20-volt…
A: The given circuit is:
Q: Speakers in stereo systems have two color-coded terminals to indicate how to hook up the wires. If…
A: Solution- Speakers - The general function of speakers is to provide audio output signal that the…
Q: What is meant by a 4-wire 3-∅ system? What advantage does it possess
A: In this question we will write about 3 phase 4 wire system....
Q: Question 10 A-How is the minimum number of receptacle outlets determined for the living room? What…
A: Since you have posted a question with multiple sub-parts, we will solve the first three sub-parts…
Q: . Draw the block diagram of a measuring system.
A: As per bartleby guideline for more than one question asked only first is to be answered please…
Q: How open circuit test can be performed? Which type of losses can be found using this test? Subjcet…
A: Open circuit test is usually performed on low voltage winding of the transformer keeping the hv…
Step by step
Solved in 2 steps with 1 images
- The following problems refer to grounding requirements. Give the source of yourresponses.1. What is the proper size copper grounding electrode conductor for a 100-ampere service that consists of 3/0 AWG ungrounded conductors?Please answer all questions and give me a sample answers, 1- What determines the ampacity of a wire? 2- When armored cable is used, what protection is provided at the cable ends? 3-A 120-volt branch circuit supplies a resistive heating load of 10 amperes. The distance from the panel to the heater is approximately 140 ft. Calculate the voltage drop using (a) 14 AWG, (b) 12 AWG, (c) 10 AWG, (d) 8 AWG copper conductors. See 210.19(A), Informational Note No. 4 and 215.2(A)(3), Informational Note No. 2. 4-In problem 3, it is desired to keep the voltage drop to 3% maximum. What minimum size wire would be installed to accomplish this 3% maximum voltage drop? See 210.19(A), Informational Note No. 4 and 215.2(A)(3), Informational Note No. 2. 5-NEC 215.2, 220.61, 230.42, and 310.15(B)(7) state that the neutral conductor of a residential service or feeder can be smaller than the phase conductors, but only 6-The allowable ampacity of a 4 AWG THHN from Table 310.15(B)(16) is 95 amperes. What…In a single-family dwelling, how is overcurrent protection for branch circuits required to be provided? See NEC 210.20. __________
- Determine the power provided by the 20-volt source in the circuit below. Indicate if the 20-volt supply is supplying power to the circuit or absorbing power from the circuit.what wire size is needed on a one 30 amp, 120/240-volt electric clothes dryer branch circuit? what wire size is needed on a one 30 amp, 240-volt electric water heater branch circuit?A bulb having a rating of 220 volts, 75 watts is to be connected to a 110 volts source. What power it draw if connected across 110 volts source? NEED ONLY NEAT HANDWRITTEN SOLUTION NO CHAT GPT
- Answer the following: Is it acceptable by code to use switch legs that have less ampacity as the rating of the circuit? Is it acceptable by code to use a breaker rated for less than the ampacity rating of the wires in a branch circuit?True or False: The line voltage power supply of an ECM should never be disconnected or connected with the power on.In the past, it was common practice to connect the lighting and receptacle(s) in a bathroom to the same circuit. Because of overloads caused by high-wattage grooming appliances, the Code now requires that these receptacle(s) be supplied by a separate 20-ampere branch circuit. Where in the Code is this requirement found? NEC __________
- 19. Which of the following is bonded to the grounding electrode system of the supply system by being connected to the equipment grounding conductor of the branch circuit? A. Equipment bonding jumperB. Auxiliary electrodeC. Pressure wire connectorD. Mounting yoke of a snap switchwhat wire size is needed on a one 20 amp, 120-volt laundry branch circuit? what wire size is needed on a one 20 amp, 120-volt garbage disposal circuit?what wire size is needed on a one 20 amp, 120-volt bathroom circuit? what wire size is needed on a one 40 amp, 120/240-volt electric range branch circuit?