5. Refer to the circuit shown in Figure 27–2. Assume that the HOA switch is in the Hand position and that the motor is running. Now assume that OL2 opens its contacts. Would this stop the operation of the fan motor? Explain your answer.

Electricity for Refrigeration, Heating, and Air Conditioning (MindTap Course List)
10th Edition
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Russell E. Smith
Chapter15: Residential Air-conditioning Control Systems
Section: Chapter Questions
Problem 8RQ
icon
Related questions
Question

5. Refer to the circuit shown in Figure 27–2. Assume that the HOA switch is in the Hand position and that the motor is running. Now assume that OL2 opens its contacts. Would this stop the operation of the fan motor? Explain your answer.

L1
L2
L3
M
OLHTR
M
OLHTR
MOTOR
M
OLHTR
STAT
STOP
HAND
CONTROL TRANSFORMER
HAND
Figure 27-3 Push-button control station with hand-off-auto
switch and pilot light. (Source: Delmar/Cengage Learning.)
OFF
AUTO
Figure 27-1 Hand-off-automatic switch provides manual control
of a motor or control can be provided by a float switch. (Source:
Delmar/Cengage Learning.)
double-throw switch with a common terminal, a nor-
mally open terminal, and a normally closed terminal
in this circuit. Notice that one terminal of both the
normally open switch and normally closed switch are
CONTROL.
TRANSFORMER
HOA
1-2 x 00
3-4 00x
HOA
START
STOP
OL1
FS1
alo
M1
M2
OL2
TEMP 1
M2
Figure 27-2 A water-cooled motor must have a flow of water before it is permitted to run. (Source: Delmar/Cengage Learning.)
Transcribed Image Text:L1 L2 L3 M OLHTR M OLHTR MOTOR M OLHTR STAT STOP HAND CONTROL TRANSFORMER HAND Figure 27-3 Push-button control station with hand-off-auto switch and pilot light. (Source: Delmar/Cengage Learning.) OFF AUTO Figure 27-1 Hand-off-automatic switch provides manual control of a motor or control can be provided by a float switch. (Source: Delmar/Cengage Learning.) double-throw switch with a common terminal, a nor- mally open terminal, and a normally closed terminal in this circuit. Notice that one terminal of both the normally open switch and normally closed switch are CONTROL. TRANSFORMER HOA 1-2 x 00 3-4 00x HOA START STOP OL1 FS1 alo M1 M2 OL2 TEMP 1 M2 Figure 27-2 A water-cooled motor must have a flow of water before it is permitted to run. (Source: Delmar/Cengage Learning.)
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Electricity for Refrigeration, Heating, and Air C…
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning