(9) A refrigerant 22 refrigeration system carries a load of 82 kW at an evaporator pressure of 354 kPa and a condenser pressure of 1460 kPa. The liquid refrigerant is subcooled by 4 degrees before entering the expansion valve and the vapor is superheated by 5 degrees before entering the compressor. The compressor operates at 28 r/s. The stroke-to-bore ratio of the twin-cylinder compressor is 1.20 and the actual volumetric efficiency is 82 per cent. Determine (a) mass flow rate of refrigerant, (b) mass flow rate of cooling water in the condenser for a 7-degree change in temperature, and (c) the bore and stroke. Ans. (a) 0.5025 kg/s, (b) 3.43 kg/s, (c) 9.2 x 11 cm

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter22: Condensers
Section: Chapter Questions
Problem 7RQ: When a standard-efficiency air-cooled condenser is used, the condensing refrigerant will normally be...
icon
Related questions
Question

Use ashrae table and charts

(9) A refrigerant 22 refrigeration system carries a load of
82 kW at an evaporator pressure of 354 kPa and a condenser
pressure of 1460 kPa. The liquid refrigerant is subcooled by 4
degrees before entering the expansion valve and the vapor is
superheated by 5 degrees before entering the compressor. The
compressor operates at 28 r/s. The stroke-to-bore ratio of the
twin-cylinder compressor is 1.20 and the actual volumetric
efficiency is 82 per cent. Determine (a) mass flow rate of
refrigerant, (b) mass flow rate of cooling water in the condenser
for a 7-degree change in temperature, and (c) the bore and stroke.
Ans. (a) 0.5025 kg/s, (b) 3.43 kg/s, (c) 9.2 x 11 cm
Transcribed Image Text:(9) A refrigerant 22 refrigeration system carries a load of 82 kW at an evaporator pressure of 354 kPa and a condenser pressure of 1460 kPa. The liquid refrigerant is subcooled by 4 degrees before entering the expansion valve and the vapor is superheated by 5 degrees before entering the compressor. The compressor operates at 28 r/s. The stroke-to-bore ratio of the twin-cylinder compressor is 1.20 and the actual volumetric efficiency is 82 per cent. Determine (a) mass flow rate of refrigerant, (b) mass flow rate of cooling water in the condenser for a 7-degree change in temperature, and (c) the bore and stroke. Ans. (a) 0.5025 kg/s, (b) 3.43 kg/s, (c) 9.2 x 11 cm
Expert Solution
steps

Step by step

Solved in 3 steps with 2 images

Blurred answer
Knowledge Booster
Refrigeration and Air Conditioning
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning