A basic D’Arsonval movement with a full-scale deflection of 50μA and an interval resistance of 1800Ω is available. It is to be converted into a 0-1V, 0-5V, 0-25V and 0-255V multirange voltmeter using individual multipliers for each range. Calculate the values of the individual resistors

Delmar's Standard Textbook Of Electricity
7th Edition
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Stephen L. Herman
Chapter12: Batteries And Other Sources Of Electricity
Section: Chapter Questions
Problem 3PA: An office building uses a bank of 63 lead-acid cells connected in series with a capacity of 80...
icon
Related questions
Question
100%
A basic D’Arsonval movement with a full-scale deflection of 50μA and an interval resistance of 1800Ω is available. It is to be converted into a 0-1V, 0-5V, 0-25V and 0-255V multirange voltmeter using individual multipliers for each range. Calculate the values of the individual resistors. [Ans. 18.2kΩ, 98.2kΩ, 498.2kΩ, 5.098MΩ]