A dryer is used to process 2000 kg/h of a material containing 40% moisture to a final product containing 5% moisture. The dryer consists of an air heater and a drying chamber. To save energy in air heating, part of the exhaust air is recycled, mixed with fresh air, and the resulting mixture is heated before feeding to the chamber. 30,000 m³ of fresh air per hour at 30°C dry bulb temperature and 65% RH are used. This is mixed with the recycled air and heated to 100°C dry bulb temperature and 42°C wet bulb temperature. The exhaust air is at 60°C. Calculate: a) the molal and absolute humidity of the exhaust air b) the fraction of the exhaust air that is recycled

Introduction to Chemical Engineering Thermodynamics
8th Edition
ISBN:9781259696527
Author:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Chapter1: Introduction
Section: Chapter Questions
Problem 1.1P
icon
Related questions
Question
A dryer is used to process 2000 kg/h of a material containing 40% moisture to a final product
containing 5% moisture. The dryer consists of an air heater and a drying chamber. To save energy
in air heating, part of the exhaust air is recycled, mixed with fresh air, and the resulting mixture
is heated before feeding to the chamber. 30,000 m of fresh air per hour at 30°C dry bulb
temperature and 65% RH are used. This is mixed with the recycled air and heated to 100°C dry
bulb temperature and 42°C wet bulb temperature. The exhaust air is at 60°C. Calculate:
a) the molal and absolute humidity of the exhaust air
b) the fraction of the exhaust air that is recycled
Transcribed Image Text:A dryer is used to process 2000 kg/h of a material containing 40% moisture to a final product containing 5% moisture. The dryer consists of an air heater and a drying chamber. To save energy in air heating, part of the exhaust air is recycled, mixed with fresh air, and the resulting mixture is heated before feeding to the chamber. 30,000 m of fresh air per hour at 30°C dry bulb temperature and 65% RH are used. This is mixed with the recycled air and heated to 100°C dry bulb temperature and 42°C wet bulb temperature. The exhaust air is at 60°C. Calculate: a) the molal and absolute humidity of the exhaust air b) the fraction of the exhaust air that is recycled
Expert Solution
steps

Step by step

Solved in 6 steps with 6 images

Blurred answer
Recommended textbooks for you
Introduction to Chemical Engineering Thermodynami…
Introduction to Chemical Engineering Thermodynami…
Chemical Engineering
ISBN:
9781259696527
Author:
J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:
McGraw-Hill Education
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemical Engineering
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY
Elements of Chemical Reaction Engineering (5th Ed…
Elements of Chemical Reaction Engineering (5th Ed…
Chemical Engineering
ISBN:
9780133887518
Author:
H. Scott Fogler
Publisher:
Prentice Hall
Process Dynamics and Control, 4e
Process Dynamics and Control, 4e
Chemical Engineering
ISBN:
9781119285915
Author:
Seborg
Publisher:
WILEY
Industrial Plastics: Theory and Applications
Industrial Plastics: Theory and Applications
Chemical Engineering
ISBN:
9781285061238
Author:
Lokensgard, Erik
Publisher:
Delmar Cengage Learning
Unit Operations of Chemical Engineering
Unit Operations of Chemical Engineering
Chemical Engineering
ISBN:
9780072848236
Author:
Warren McCabe, Julian C. Smith, Peter Harriott
Publisher:
McGraw-Hill Companies, The