A turbo feed pump requires driving saturated water from the condenser into the boiler. The condenser pressure is 0.1 bar and the boiler pressure is 100 bar. The required feed water flow to the boiler is 0.2 m3 / sec and in the drive process the water increases its temperature by 2° C. The inlet pipe to the pump has a diameter of 60 cm and at the discharge it is 35 cm. On the drive side of the turbo pump, it has saturated steam at 25 bar at the inlet and at the discharge it has a pressure of 0.1 bar and a quality of 0.65. Determine: a) The mass flow of feed to the boiler b) The real power of the turbo pump assuming an efficiency of 90% in the water delivery c) The mass flow of steam through the turbo pump, for this calculation, neglect the effect of speeds. d) Steam velocity in the supply pipe to the turbo pump if it has a diameter of 30 cm. CV Turbine Pump

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter45: Domestic Refrigerators And Freezers
Section: Chapter Questions
Problem 13RQ: Condensers in these refrigerators are all_______cooled.
icon
Related questions
Question
A turbo feed pump requires driving saturated water
from the condenser into the boiler. The condenser
pressure is 0.1 bar and the boiler pressure is 100 bar.
The required feed water flow to the boiler is 0.2 m3 /
sec and in the drive process the water increases its
temperature by 2° C.
The inlet pipe to the pump has a diameter of 60 cm
and at the discharge it is 35 cm.
On the drive side of the turbo pump, it has saturated
steam at 25 bar at the inlet and at the discharge it
has a pressure of 0.1 bar and a quality of 0.65.
Determine:
a) The mass flow of feed to the boiler
b) The real power of the turbo pump assuming an
efficiency of 90% in the water delivery
c) The mass flow of steam through the turbo pump,
for this calculation, neglect the effect of speeds.
d) Steam velocity in the supply pipe to the turbo
pump if it has a diameter of 30 cm.
3.
2
W.
CV
Turbine
Pump
Transcribed Image Text:A turbo feed pump requires driving saturated water from the condenser into the boiler. The condenser pressure is 0.1 bar and the boiler pressure is 100 bar. The required feed water flow to the boiler is 0.2 m3 / sec and in the drive process the water increases its temperature by 2° C. The inlet pipe to the pump has a diameter of 60 cm and at the discharge it is 35 cm. On the drive side of the turbo pump, it has saturated steam at 25 bar at the inlet and at the discharge it has a pressure of 0.1 bar and a quality of 0.65. Determine: a) The mass flow of feed to the boiler b) The real power of the turbo pump assuming an efficiency of 90% in the water delivery c) The mass flow of steam through the turbo pump, for this calculation, neglect the effect of speeds. d) Steam velocity in the supply pipe to the turbo pump if it has a diameter of 30 cm. 3. 2 W. CV Turbine Pump
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Refrigeration and Air Conditioning
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning