Air Leakage and Ventilation Problem: Blower Door Test A blower door test was conducted during an ecoENERGY audit on a leaky old 1920’s solid masonry house in Toronto. The results indicated that the house experienced 7.28 ACH (air changes per hour) at 50 Pascals of de-presurization. The house measures 12m wide by 10m long, and 8m tall (above grade) and 3m below grade depth. The attic was sealed off during the test and can be ignored. If the house is heated with electricity at a total cost of $0.10/kWh, calculate the cost of the uncontrolled air leakage, accounting for both heating the air (sensible heat) and the humidification (latent heat) under an every- day pressure difference caused by wind and stack effect, over the month of January (31 days). To convert the 50 Pascal air leakage rate to a normal every-day pressure air leakage rate, several wise building scientists suggested taking 5% of the 50 Pascal leakage as a reasonable approximation. Assume the indoor conditions to be 20oC and 35% rh, and outside to be an average -5oC and 65% rh, while the total atmospheric pressure is 101.325 KPa

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question
Air Leakage and Ventilation Problem: Blower Door Test A blower door test was conducted during an ecoENERGY audit on a leaky old 1920’s solid masonry house in Toronto. The results indicated that the house experienced 7.28 ACH (air changes per hour) at 50 Pascals of de-presurization. The house measures 12m wide by 10m long, and 8m tall (above grade) and 3m below grade depth. The attic was sealed off during the test and can be ignored. If the house is heated with electricity at a total cost of $0.10/kWh, calculate the cost of the uncontrolled air leakage, accounting for both heating the air (sensible heat) and the humidification (latent heat) under an every- day pressure difference caused by wind and stack effect, over the month of January (31 days). To convert the 50 Pascal air leakage rate to a normal every-day pressure air leakage rate, several wise building scientists suggested taking 5% of the 50 Pascal leakage as a reasonable approximation. Assume the indoor conditions to be 20oC and 35% rh, and outside to be an average -5oC and 65% rh, while the total atmospheric pressure is 101.325 KPa
Expert Solution
steps

Step by step

Solved in 1 steps

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning