Consider the given truss and connection detail for member CF as shown. Member CF is made of ASTM A992 steel (Fy - 350 MPa; Fu 450 MPa), rolled as L125 x 125 x 10 shape. The connection is made of three 25-mm diameter bolts, arranged in one row at the centroidal line. The load P applied on the truss nodes is composed of both dead and live loads. Using LRFD specifications, determine the maximum permissible service live load LL (assume 1.2DL+ 1.6LL load combination governs) (in kN) that can be applied on the truss such that the design of member CF is adequate. Assume all other members and gusset plates are adequately designed. The ratio of service live load to service dead load is 3.0. All truss dimensions are in mm.

Steel Design (Activate Learning with these NEW titles from Engineering!)
6th Edition
ISBN:9781337094740
Author:Segui, William T.
Publisher:Segui, William T.
Chapter6: Beam–columns
Section: Chapter Questions
Problem 6.9.2P
icon
Related questions
Question
100%
36.070
3600
66.030
48.366
36,870
D.
4800
9600
4800
50
50 + 50
Pcf
Transcribed Image Text:36.070 3600 66.030 48.366 36,870 D. 4800 9600 4800 50 50 + 50 Pcf
Consider the given truss and connection detail for member CF as shown. Member CF is made of ASTM A992
steel (Fy = 350 MPa; Fu- 450 MPa), rolled as L125 x 125 x 10 shape. The connection is made of three 25-mm
diameter bolts, arranged in one row at the centroidal line. The load P applied on the truss nodes is composed of
both dead and live loads.
Using LRFD specifications, determine the maximum permissible service live load LL (assume 1.2DL+ 1.6LL load
combination governs) (in kN) that can be applied on the truss such that the design of member CF is adequate.
Assume all other members and gusset plates are adequately designed. The ratio of service live load to service
dead load is 3.0.
All truss dimensions are in mm.
3600
36.870
7200
36.870
3600
66.038
46.366
36.870
Transcribed Image Text:Consider the given truss and connection detail for member CF as shown. Member CF is made of ASTM A992 steel (Fy = 350 MPa; Fu- 450 MPa), rolled as L125 x 125 x 10 shape. The connection is made of three 25-mm diameter bolts, arranged in one row at the centroidal line. The load P applied on the truss nodes is composed of both dead and live loads. Using LRFD specifications, determine the maximum permissible service live load LL (assume 1.2DL+ 1.6LL load combination governs) (in kN) that can be applied on the truss such that the design of member CF is adequate. Assume all other members and gusset plates are adequately designed. The ratio of service live load to service dead load is 3.0. All truss dimensions are in mm. 3600 36.870 7200 36.870 3600 66.038 46.366 36.870
Expert Solution
steps

Step by step

Solved in 6 steps with 15 images

Blurred answer
Knowledge Booster
Roof plan components
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Steel Design (Activate Learning with these NEW ti…
Steel Design (Activate Learning with these NEW ti…
Civil Engineering
ISBN:
9781337094740
Author:
Segui, William T.
Publisher:
Cengage Learning