Determine the total DC resistance of the subscriber loop (including the telephone)

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter4: Transmission Line Parameters
Section: Chapter Questions
Problem 4.26P
icon
Related questions
Question

Determine the total DC resistance of the subscriber loop (including the telephone)

Scenario for Part 1:
A telecommunication company is tasked to design a subscriber loop that will follow the road map below to provide telephone services in a
subdivision. The initially designated service area interface (116 C. Lawis Extension) and the distribution point (San Luis, Antonio) are 3.7 km and
4.5 km, respectively, from the central office. One subscriber is 0.4 km from the distribution point (4.9 km from the central office).
ty
Cloud 9 Sports
and Leisure Club
Palos Verdes
Immaculate Heart
of Mary (Diocese of....
Burrow Cafe PH
Kaulayaw Café
Cabrera d
Richdale Subdivision
SANTA CRUZ
Tipulo (10)
Cristina Villas
Mountain Resort
Summerhills
Executive Village
Hinulugang Taktak
DELA PAZ
Ynares Center
PLDT- Antipolo O
Vaccinated Staff-OYOp
588 Sunrock Resort
SAN ISIDRO
SAN ROQUE
Fortune Park Resort
Mall Antipolo
116 C. Lawis Extension
4.9 km
SAN LUIS Mystical Cave
La Salle Avenue
E Rodriguez Ave
Vista Mall Antipolo
Transfiguration+
1 hr 6 min
St. Gabriel Heights
Gogle Star Resort
Antipolo
Solid Cement
Corporation
DALIG TERRAZA DE
ANTIPOLO
SAN JOSE
EL Dorado, Brgy. San
Jose, Antipolo City
VIRGEN DELA PAZ
BRGY. SAN JOSE...
Rd
Rod
Teresa
Pantay Ele
Transcribed Image Text:Scenario for Part 1: A telecommunication company is tasked to design a subscriber loop that will follow the road map below to provide telephone services in a subdivision. The initially designated service area interface (116 C. Lawis Extension) and the distribution point (San Luis, Antonio) are 3.7 km and 4.5 km, respectively, from the central office. One subscriber is 0.4 km from the distribution point (4.9 km from the central office). ty Cloud 9 Sports and Leisure Club Palos Verdes Immaculate Heart of Mary (Diocese of.... Burrow Cafe PH Kaulayaw Café Cabrera d Richdale Subdivision SANTA CRUZ Tipulo (10) Cristina Villas Mountain Resort Summerhills Executive Village Hinulugang Taktak DELA PAZ Ynares Center PLDT- Antipolo O Vaccinated Staff-OYOp 588 Sunrock Resort SAN ISIDRO SAN ROQUE Fortune Park Resort Mall Antipolo 116 C. Lawis Extension 4.9 km SAN LUIS Mystical Cave La Salle Avenue E Rodriguez Ave Vista Mall Antipolo Transfiguration+ 1 hr 6 min St. Gabriel Heights Gogle Star Resort Antipolo Solid Cement Corporation DALIG TERRAZA DE ANTIPOLO SAN JOSE EL Dorado, Brgy. San Jose, Antipolo City VIRGEN DELA PAZ BRGY. SAN JOSE... Rd Rod Teresa Pantay Ele
Given the following specifications:
18
19
20
21
22
23
24
25
Component
Switch
26
Service area interface
Distribution point
Feeder cable
The sizes of the copper cables are shown in the table of the American Wire Gauge.
AWG
Diameter (in)
Diameter (mm)
Distribution cable
Drop wire
Telephone
(touch tone)
0.0403
0.0359
0.0320
0.0285
0.0253
0.0226
0.0201
0.0179
0.0159
1.024
0.912
0.812
0.723
0.644
0.573
0.511
0.455
Specification
Minimum current
Maximum current
0.405
DC Voltage
Attenuation limit
Capacity (in)
Capacity (out)
Capacity (in)
Capacity (out)
AWG # (copper)
Attenuation
AWG # (copper)
Attenuation
AWG # (copper)
Attenuation
On-hook resistance
Off-hook resistance
Value
24 mA
96 mA
-48 V
9 dB
3600 pairs
200 pairs
200 pairs
24 pairs
18
0.7 dB/km
19
0.8 dB/km
20
0.9 dB/km
3 M-ohms
200 ohms
Transcribed Image Text:Given the following specifications: 18 19 20 21 22 23 24 25 Component Switch 26 Service area interface Distribution point Feeder cable The sizes of the copper cables are shown in the table of the American Wire Gauge. AWG Diameter (in) Diameter (mm) Distribution cable Drop wire Telephone (touch tone) 0.0403 0.0359 0.0320 0.0285 0.0253 0.0226 0.0201 0.0179 0.0159 1.024 0.912 0.812 0.723 0.644 0.573 0.511 0.455 Specification Minimum current Maximum current 0.405 DC Voltage Attenuation limit Capacity (in) Capacity (out) Capacity (in) Capacity (out) AWG # (copper) Attenuation AWG # (copper) Attenuation AWG # (copper) Attenuation On-hook resistance Off-hook resistance Value 24 mA 96 mA -48 V 9 dB 3600 pairs 200 pairs 200 pairs 24 pairs 18 0.7 dB/km 19 0.8 dB/km 20 0.9 dB/km 3 M-ohms 200 ohms
Expert Solution
steps

Step by step

Solved in 4 steps with 16 images

Blurred answer
Knowledge Booster
Electric heating unit
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning