The parameters of a 200/400V 50HZ single phase transformer are given below: Zı= 0.2 + j0.4 N, Zz= 1.3 + jl.5 N, R,=300 N, X,=400 N and ZL= 10 + j10 N. If the primary voltage equal to the nominal value, find by using the exact equivalent circuit: (i) Input current and power factor, (ii) The load voltage, (iii) The voltage regulation, (iv) The efficiency.
Q: A single-phase, dry-type, general-purpose industrial distribution A transformer has the…
A: Given data, P=50 kVAf=60 HzVH=480 VVL=120 VZimpedance=3.80+j4.43 Ω%R=3.80 Ω%X=4.43 ΩPi=105 W
Q: A 10 kVA, 2400/240 V, 60 Hz single phase transformer has Z, = 5.2 + j12.5 ohms and Z2 = 0.06 + j0.12…
A: In this question, We need to calculate the load voltage if Primary voltage and frequency is rated.…
Q: A 6.9 kV/600 V, multi-tap, single-phase distribution transformer is connected to the far end of a…
A: Consider the following single line diagram of the system,
Q: Q2. Consider the single-phase transformer circuit shown below. Transformer ratings and reactances…
A:
Q: A 1-phase transformer, 15 kVA, 660/250V, 50HZ, Reg1= 2.78790 and Xegi = 5.57572. %3D the secondary…
A: According to the question, we have to calculate the value of regulation up at full load and power…
Q: A 2,300/240-V, 60-Hz, 4.6-kVA transformer isdesigned to have an induced emf of 2.5 V/turn.Assuming…
A: The given transformer is a step-up transformer. a. The numbers of high-side turns are calculated as…
Q: A single phase transformer is rated 2400V/240V, 500kVA 50HZ yields the following primary side…
A: Solution Given data, Vbase =2400 V Sbase =500×103 VA base values can…
Q: A 40-kVA, 8000/230-V distribution transformer has an impedance referred to the primary of 18 + j80…
A: In this question we need to find a secondary voltage of the transformer.
Q: 1) A single-phase 100-kVA, 2,400/240 V, 60-Hz distribution transformer is used as a step-down…
A:
Q: Given a 10 KVA, 1200/180 V, 50 Hz single-phase transformer with an impedance Zp = 10+j20 Ohms…
A: To find the equivalent impedance when referred to secondary side of the transformer
Q: 3. A single-phase 30KVA, 2000V/200V, 60HZ distribution transforme transformer at the load end of a…
A: The transformer problem can be solved as below.
Q: A 6.9 kV/600 V, multi-tap, single-phase distribution transformer is connected to the far end of a…
A: This question is from "Power System". Under which we are going to study about the whole…
Q: QI An 11,000/230-V, 150-kVA, 50-Hz, 1-phase transformer has a core loss of 1.4 kW and full-load…
A: Given data: Core loss = 1.4 kW Full load Copper loss= 1.6 kW Full load KVA =150 Power factor…
Q: A 15-kVA 8000/230-V distribution transformer has an impedance referred to the prima of 80+ j3000.…
A: a. The turns ratio of the transformer is determined as a=8000230=34.78 The load impedance referred…
Q: (b) Mr. Musa Al Biruni is analyzing a 100 kVA, 60 Hz, 7200-480V, single phase transformer, which has…
A:
Q: Power transformer A, has Rated power of 150MVA. Line voltage of 330/66 kV Frequency=50Hz Connection…
A: Active Power across the Load = Apparent Power ×power factor ---- 1) Putting value in equation -1)…
Q: Question 1 A 132/33 kV 250 MVA single-phase step-down transformer has the following parameters: R1 =…
A:
Q: An Electrical engineer is asked by a client to prepare a technical specification on specific items…
A: Given: An Electrical engineer is asked by a client to prepare a technical specification on specific…
Q: Given a 20 kVA, 50 Hz, 2000/200 V single-phase transformer. The parameters of the transformer…
A: Given data 20kVA, 50Hz, 2000/200V transformer R1 = 0.5, R2 = 0.005, X1 = 0.5, X2 = 0.005, Rc = 500…
Q: A 20-kVA, 8000:480-V distribution transformer has the following resistances and reactances: Rp= 32…
A: Note: We are authorized to answer three subparts at a time, since you have not mentioned which part…
Q: The parameters of a 1000/250V, 50HZ single phase transformer are: R1=1.3 N, X1=2.8 N, R2=0.11 N,…
A:
Q: a three-phase step-down transformer with 150 kVA, 2080/208 V 60 Hz Y / Y connected R1 = 0.45 ohm, X1…
A:
Q: The transformer shown operates at 50Hz with the turn numbers N1=200 and N2=100 for primary and…
A:
Q: A 2.4-kVA, 2400/240-V, 50-Hz, step-down transformer has the following parameters: R, = 1.5 a, X, =…
A:
Q: For the ideal transformer circuit shown, the primary current Il1 is found to be 7.86 + jo A when…
A:
Q: The parameters of a 200/400V 50Hz single phase transformer are given below: Z₁=0.5+j1.8, Z₂= 0.2 +…
A:
Q: A transformer of 100MVA, 60Hz, 138/69 kV, works as step down, has the following parameters: r1 =…
A:
Q: A 400-turns auto transformer, operating in the step-down mode with 25 percent tap supplies a 4.8…
A:
Q: A 30-kVA, 8000/230-V distribution transformer has impedance referred to the primary of 20 + j100 N.…
A: We are authorized to answer one part of the question at a time since you have not mentioned which…
Q: We have 10kVA, 4800/240 V, 50Hz single phase transformer. R1 is measured as R1 = 20 Ω From the…
A: We are authorized to answer three subparts at a time, since you have not mentioned which part you…
Q: a single-phase 250KVA, 11kV/2.2kV, 60HZ transformer has the following parameters. RHy = 1.3 Q RLy =…
A: Given data Single phase rating is S = 250 KVA Frequency is F = 60 Hz Calculating k k=2.2 KV1.1…
Q: Example 32.72. A 300-kVA, single-phase transformer is designed to have a resistance of 1.5% and…
A:
Q: The efficiency of a 440/110V, 40kVA, single-phase transformer is 98.77% when delivering ll-load at…
A: A single phase transformer is a device whose input and output are single phase. They are used for…
Q: . A 15kVA single-phase transformer, for 10000V/440V at no load, has resistances and leakage…
A: In this question, We need to determine the value of the secondary voltage at full load, 0.85 power…
Q: A 4800/240-V, single phase transformer is rated at 10 kVA. It has an equivalent impedance referred…
A:
Q: Given a 20 kVA, 50 Hz, 2000/200 V single-phase transformer. The parameters of the transformer…
A: In this question we need to find a input power factor of transformer.
Q: 3. A single-phase 100-kVA, 7200-V/120-V, 60HZ distribution transformer is used as a step down…
A: transformation ratio, primary side impedance, secondary side impedance, primary and secondary side…
Q: Question 1 An ideal two winding transformer with a rectangular cross-sectional area of 60cm by 20cm…
A:
Q: Q2. Consider the single-phase transformer circuit shown below. Transformer ratings and reactances…
A: We will use following formula of Zp.u to find Zpu on common on common base values Znew (P.u)=…
Q: A 40-kVA, 8000/230-V distribution transformer has an impedance referred to the primary of 18 + j80…
A:
Q: carrying? Ans. 10 45 percent 10.44 A 100-KVA transformer is at 80 percent of rated load at power…
A:
Q: Mr. Musa Al Biruni is analyzing a 100 kVA, 60 Hz, 7200-480V, single phase transformer, which has the…
A: From the given data IP=SEP=100×1037200=13.88 AIs=SEs=100×103480=208.3 A The equivalent circuit will…
Q: Q.32: For the equivalent circuit of lossless linear transformer shown, find the value of L. L2, M &…
A:
Q: A 15-kVA 8000/230-V distribution transformer has an impedance referred to the primary of 80 + j3002.…
A: Part (a): The turn ratio of the transformer is determined as: a=8000 V230 V=34.78 The load impedance…
Q: The parameters of a 400/100V, 50Hz single phase transformer are given below: Z 1+j10, Z₂= 0.1 +…
A:
Q: A 240-kVA, 480/4800-V, step-up transformer has the following constants: Rs = 2.5 Ω, Xs = j5.75 Ω, Rp…
A: Given step up Transformer with240 KVA, 480/4800 vRs=2.5 Ω,Xs=j5.75 ΩRp=25 mΩ,Xp=j57.5 ΩThe core…
Q: Primary side-reduced equivalent circuit parameters of a 25 KVA, 50 Hz, 4000/400 Volt transformer R1…
A: Given: A 25KVA, 50Hz, 4000/400V transformer in which…
Q: Question 1 An ideal two winding transformer with a rectangular cross-sectional area of 60cm by 20cm…
A: Answer A = 60cm x 20cm =1200cm2 = 1200x10-4 c m2 k = N2N1 = 0.02N2 = 400 V2 = 220 v I2 = 200 Acosϕ =…
Q: 9. A 10-kVA, 2000/400-V, single-phase transformer has resistances and leakage reactances as follows:…
A: Given, Primary voltage, V1 = 2000 V Secondary voltage, V2 = 400 V So, transformation ratio,…
Q: The parameters of a 1200/300V. 50HZ single phase transformer are given below: R,-50, X,-10 0, R 0.3…
A: We are authorized to answer three subparts at a time, since you have not mentioned which part you…
Step by step
Solved in 6 steps with 6 images
- A single-phase 100-kVA,2400/240-volt,60-Hz distribution transformer is used as a step-down transformer. The load, which is connected to the 240-volt secondary winding, absorbs 60 kVA at 0.8 power factor lagging and is at 230 volts. Assuming an ideal transformer, calculate the following: (a) primary voltage, (b) load impedance, (c) load impedance referred to the primary, and (d) the real and reactive power supplied to the primary winding.Consider Figure 3.25 of the text for a transformer with off-nominal turns ratio. (i) The per-unit equivalent circuit shown in part (c) contains an ideal transformer which cannot be accommodated by some computer programs. (a) True (b) False (ii) In the - circuit representation for real c in part (d), the admittance parameters Y11 and Y12 would be unequal. (a) True (b) False (iii) For complex c, can the admittance parameters be synthesized with a passive RLC circuit? (a) Yes (b) NoA two-winding single-phase transformer rated 60kVA,240/1200V,60Hz, has an efficiency of 0.96 when operated at rated load, 0.8 power factor lagging. This transformer is to be utilized as a 1440/1200-V step-down autotransformer in a power distribution system. (a) Find the permissible kVA rating of the autotransformer if the winding currents and voltages are not to exceed the ratings as a two-winding transformer. Assume an ideal transformer. (b) Determine the efficiency of the autotransformer with the kVA loading of part (a) and 0.8 power factor leading.
- An infinite bus, which is a constant voltage source, is connected to the primary of the three-winding transformer of Problem 3.53. A 7.5-MVA,13.2-kV synchronous motor with a sub transient reactance of 0.2 per unit is connected to the transformer secondary. A5-MW,2.3-kV three-phase resistive load is connected to the tertiary Choosing a base of 66 kV and 15 MVA in the primary, draw the impedance diagram of the system showing per-unit impedances. Neglect transformer exciting current, phase shifts, and all resistances except the resistive load.Consider Figure 3.4. For an ideal phase-shifting transformer, the imda nce is unchanged when it is referred from one side to the other. (a) True (b) FalseAn ideal transformer has no real or reactive power loss. (a) True (b) False
- A single-phase 50-kVA,2400/240-volt,60-Hz distribution transformer is used as a step-down transformer at the load end of a 2400-volt feeder whose series impedance is (1.0+j2.0) ohm. The equivalent series impedance of the transformer is (1.0+j2.5) ohms referred to the high-voltage (primary) side. The transformer is delivering rated load at a 0.8 power factor lagging and at a rated secondary voltage. Neglecting the transformer exciting current, determine (a) the voltage at the transformer primary terminals, (b) the voltage at the sending end of the feeder, and (c) the real and reactive power delivered to the sending end of the feeder.A single-phase, 50-kVA,2400/240-V,60-Hz distribution transformer has the following parameters: Resistance of the 2400-V winding: R1=0.75 Resistance of the 240-V winding: R2=0.0075 Leakage reactance of the 2400-V winding: X1=1.0 Leakage reactance of the 240-V winding: X2=0.01 Exciting admittance on the 240-V side =0.003j0.02S (a) Draw the equivalent circuit referred to the high-voltage side of the transformer. (b) Draw the equivalent circuit referred to the low-voltage side of the transformer. Show the numerical values of impedances on the equivalent circuits.Consider a source of voltage v(t)=102sin(2t)V, with an internal resistance of 1800. A transformer that can be considered as ideal is used to couple a 50 resistive load to the source. (a) Determine the transformer primary-to-secondary turns ratio required to ensure maxi mum power transfer by matching the load and source resistances. (b) Find the average power delivered to the load, assenting maximum power transfer.
- The parameters of a 1000/250V, 50HZ single phase transformer are: R1=1.3 N, X1=2.8 N, R2=0.11 N, X2=0.2 N, R,=250 N, X,=900 N. If the load voltage is 220V, load power is 10kW, and load power factor is 0.8 lagging. Find by using the exact equivalent circuit: (i) Input current, (ii) The input voltage and power factor, (iii) The magnetizing current, (iv) The copper losses, (v) The voltage regulation.In a three-phase step-down transformer with 150 kVA, 2080/208 V 60 Hz Y / Y connected R1 = 0.45 ohm, X1 = 2.2 ohm, R2 = 4.5 mohm, X2 = 22 mohm, Rc = 10 kohm, Xm = 8 kohms. When installed at 120 kVA, 90 kW back power factor, if the voltage at the load ends is at its nominal value, a) Primary side terminal voltage b) Yield (efficiency) c) Calculate the voltage regulation value?A 20-kVA 8000/277-V distribution transformer has the following resistances and reactance: RP = 32 Ω RS = 0.05Ω X P = 45Ω XS = 0.06Ω RC = 250 kΩ X M = 30 kΩ The excitation branch impedances are given referred to the high-voltage side of the transformer. (a) Find the equivalent circuit of this transformer referred to the high-voltage side. (b) Find the per-unit equivalent circuit of this transformer. (c) Assume that this transformer is supplying rated load at 277 V and 0.8 PF lagging. What is this transformer’s input voltage? What is its voltage regulation? (d) What is the transformer’s efficiency under the conditions of part (c)?