Highly skilled labour is required in O casing caping wiring O TRS wiring OConduit wiring Both conduit and casing-caping wiring
Q: 20. Two support messengers in an expansion loop are separated by 30 cm. What's the minimum bend…
A: Given that Two support messengers in expansion loop are separated by 30cm Hence the bend radius for…
Q: B) You have a choice between a cable where the transformer box is at the very end (right where you…
A: The loss in a cable is given by I2R where I is the current and R is the resistance of the cable.…
Q: 10.a. What's the best way to terminate cables with large fiber counts and splices? A. Cables should…
A: “Since you have asked multiple questions, we will solve the first question for you. If you want…
Q: Practically it is possible the _______________ cables pass through on poles along with high voltage…
A: In this problem, which cable are practically possible cables pass through on poles along with high…
Q: True or False Normal bonding methods are considered adequate for most circuits
A: The above given statement is TRUE because "Normal bonding methods are considered adequate for most…
Q: A household three-way switch is used to allow lights to be controlled from two loca- tions (e.g., at…
A: Three way switch type is SPDT single pole double throw. Two switches
Q: Highly skilled labour is required in O TRS wiring O casing - caping wiring O Conduit wiring O Both…
A: We are authorized to answer one question at a time, since you have not mentioned which question you…
Q: All of these are common branch circuit problems except A) undersized wire. B) damaged wires. C) open…
A:
Q: A feeder is installed to feed a sub panel. The feeder starts at a 400-amp breaker, utilizing (2)…
A: Equipment grounding conductor is providing ground fault current path.
Q: Use nodal analysis to determine each of the circuit parameters for the provided circuit
A: The circuit is shown below: Using the nodal analysis, VA=40 VVC=10 VVB-VAR1+VBR3+VB-VCR2=0
Q: If the cable in Figure ran for the whole of its length, grouped with others of the same size in a…
A: Ambient temperature – The standard or reference temperature for the installation of cables is…
Q: ____ must not be installed beneath openings through which materials may be moved, such as openings…
A: From Article 230 of National Electric Code (NEC), the following information can be obtained: Service…
Q: A 400-amp circuit breaker protects a feeder that's installed in a nonmetallic raceway that requires…
A: Circuit Breaker- It is used as switch which works as a safety device for the circuit and circuit…
Q: What is RG rating of coaxial cable. Please give me detailed information. Don't copy previously given…
A:
Q: 3.a. When a device is removed from an outlet box, the_______ wire must be connected in such a way…
A:
Q: 3. If this circuit were used in a digital circuit, it would be a NOT gate. a. True b. False
A:
Q: have an underground buried cable, suppose the cable is derected (oper circuit) somewhere along its…
A: Given that an underground buried cable has open circuit fault and we have to locate the position of…
Q: 150 kv single core cable has a radius of cable of 5cm. The insulation martial has two layers. The…
A: This is a good question based on the power system distribution topic in power systems. In this the…
Q: 9/ The Underground Cable operating at a Nominal Voltage of 36 KV is classified as Super Tension…
A: The detailed answer is solved below according to the given parameters and instructions in the…
Q: To protect the cable from moisture in the soil, a metallic sheath of material is provided over the…
A: In cables metallic sheath is provided after insulation to protect the cable from moisture.
Q: 11. Specific rules apply for the installation of _______, but no identification requirements for…
A: Specific rules apply for the installation of ----------, but no identification requirements for them…
Q: illustrated in your reading material, the plug-in busway for motor Branch circuits has tap- off…
A: Correct option is c part.
Q: Zener breakdown takes place due to 1. Direct rupture of covalent bonds,
A: Zener diodes are highly doped P-N junction diode with main difference with conventional Si diode is…
Q: A 240V, 40A, single-phase load is located 150 ft from an existing junction box. The junction box is…
A: Given V = 240 V I = 40 A L1 =150 ft L2 =50 ft
Q: In an outdoor substation the three bus-bar conductors are supported by units of post type…
A:
Q: 7.B. The size of a grounding electrode conductor for a service or separately derived system is…
A: 7.B. The size of a grounding electrode conductor for a service or separately derived system is…
Q: conditions
A: So the correct option is option "A"...
Q: The fuse link in dual element time delay fuses is designed to ______ under a large amount of…
A: The fuse link limits the short-circuit current by quickly vaporizing the small restricted portions…
Q: Question 6: 1- List the pins on Arduino that can do analog write.
A: As per the honor code I will solve only first question. Kindly repost the other questions again.…
Q: 1.a. Section 300.15(C) requires a fitting to be installed on each end of a conduit or tubing being…
A: 1.a. According to NEC section 300.15(C), A conduit or box body shall not be required where cables…
Q: Which is a non permanent way of building a circuit? O stripboard О РСВ O Thick-film O Breadboard
A: The strip board is the board that are used to make the permanent circuits, the board is used where a…
Q: 2- What is the function of the following figure? A, Az Az A, - Count = 1 - Clear - I Load Counter -…
A:
Q: 1.a. A fiber optic cable has a minimum bend radius of 8 cm and will be mounted in an expansion loop…
A:
Q: of 14 Question The function of a(n) is to show how components in an electrical system are connected…
A: correct option is specification sheet the specification sheet gives the details about the…
Q: 14.a. Where should fiber optic cables that are fixed in cable trays be installed? A. In riser spaces…
A: In this question we are to determine : Where should fiber optic cables that are fixed in cable…
Q: Where a 2 1/2 inch conduit enters an angle pull box with three 400 MCM type THHN conductors and a 2…
A: For angle pulls, the distance between each raceway entry inside the baox and the opposite wall of…
Q: Service conductors supplying a building or other structure must not of another building or other…
A: From Article 230 of National Electric Code (NEC), the following information can be obtained:Service…
Q: Open loop control system are simple and stable O complex and unstable simple and unstable O accurate…
A: Given A multiple choice question basedbon open loop control system. Please find the below…
Q: the most commonly used wire installation in domestic use is by - * O Cable tray O trucking O…
A:
Q: Describe in your own words the features of (i) Arduino UNO (ii) Arduino NANO (iii) Arduino MEGA With…
A: Discuss features of given Electronic board (i) Arduino UNO (ii) Arduino NANO (iii) Arduino MEGA With…
Q: COLUMN A A copper wiring containing 8 color-coded COLUMN B 1. conductors or 4 twisted pairs that…
A: 1. A-copper wiring containing 8 color-coded conductors or 4 twisted pairs that offers greater…
Q: 16. A conductor installed from a bonding/grounding bushing that's used to provide a conducting…
A: A conductor installed from a bonding/grounding bushing that's used to provide a conducting…
Q: Fill in the blank: Due to the electromegnatic isloation it is possible we can install the…
A: Solution : Electro magnetic isolation is also called as electro magnetic shielding.
Q: MCCB, is Miniature Case Circuit Breaker. Select one: True
A: MCCB useful for protection against short circuit faults.
Q: 1. A14/2 type copper used for a general lighting branch circuit.…
A: Hello. Since your question has multiple parts, we will solve first question for you. If you want…
Q: True or False: Industrial safety requires to use of the lockout tags when you do not maintain or…
A: The electrical machines operate at high voltages and high currents. These level of voltages and…
Q: 7) What do you will suggest to the Director to do to be able to use the Channel 2 without the fear…
A: Given information
Q: True or false: Vampire tap is a component use to connect the coaxial cable with the patch panel.…
A: We need to tell about whether the given statement is true or false
Q: For the circuit shown in figure 4 Calculate the value of ITotal & IC1
A: In this question, We need determine the total current and current in the capacitor C1. We are…
Step by step
Solved in 2 steps
- Most conduit and tubing type raceways have a maximum equivalent of four ______ bends between pull points, for example, conduit bodies and boxes. Select one: A. 45 DEGREE B. 180 DEGREE C. 90 DEGREE D. 360 DEGREERaceway fill calculations are a prerequisite in ____ needed for particular circuits. Select one: A. MATERIAL REQUIREMENTS B. SCHEMATIC REQUIREMENTS C. DETERMINING THE SIZE OF RACEWAY D. CIRCUIT LOADSNEC identifies ____ types of rigid PVC conduit. Select one: A. FIVE B. TEN C. THREE D. TWO
- NEED SOLUTION WITH PERFECT EXPLAINATIONGive any sample of electrical components/processes that single and three phase electric transformer application plays important role. Draw the diagram and label each part. please draw me and label each part.EQUIPMENT GROUNDING A 400-amp circuit breaker protects a feeder that's installed in a nonmetallic raceway that requires an equipment grounding conductor. Which of the following is the minimum size of aluminum equipment grounding conductor that should be used in this situation? A. No. 4B. No. 1C. No. 6 D. No. 2
- Service conductors supplying a building or other structure must not of another building or other structure. A. Be installed on the exterior walls B. Pass through the interior C. A and B D. None of theseWe are running 3 wires in an IMC to a control panel with a 150 amp circuit breaker disconnect in the control panel. The conduit is run 12 inches above the roof on a strut rack. The ambient air temperature is 88 degrees. This control panel feeds the #1 cooling fan. What sized ungrounded conductors do we need? All conductors have typeTHHN insulation. A #1 AWG B 100 Kcmil C #1/0 AWG D #10 AWG What sized IMC do we need? A 3/4" B 1 1/4" C 1" D 1 1/2"3.a. When a device is removed from an outlet box, the_______ wire must be connected in such a way that maintains continuity. A. neutral B. grounding C. hot D. grounded neutral 3. To correctly saw a lath and plaster wall, point the teeth of the saw A. away from you and cut on the pushing stroke. B. away from you and cut on the pulling stroke. C. toward you and cut on the pushing stroke. D. toward you and cut on the pulling stroke.
- Course: Electrical Engineering Subject: Electrical Apparatus The high-tension winding of a 100-KVA; 2,300/575 volts, 60-cycle transformer consists of 200 turns of copper conductors. Determine: (a) turns in the low-tension side; (b) rated current of the high and low side winding.A multiconductor cable, optical fiber cable, or flexible cords of two or more conductors is treated as ____ for percentage conduit fill area calculations. Select one: A. A NEUTRAL NODE B. THREE CONDUCTORS C. TWO CONDUCTORS D. A SINGLE CONDUCTORQuestion 5 Full explain this question very fast solution sent me step by y The transformer has a turns ratio of 9.45What is the dc load voltage CONSIDERING the ripple voltage?What is the dc load voltage WITHOUT CONSIDERING the ripple Not:- text typing work only