na two stage regeneration system, steam at 26 bar and 400 degrees * C is supplied at a rate of 127*10^ 3 kg/hr The extractions are 10400 kg/hr at 2.9 bar and 8700 kg/hr at 0.6 par. The condenser pressure is 5 cm of Hg. Actual feed water temperature is 125 degrees * C . Find out the percentages of extracted steam at both points and thermal efficiency of the system. The power output From the plant is 25 MW
na two stage regeneration system, steam at 26 bar and 400 degrees * C is supplied at a rate of 127*10^ 3 kg/hr The extractions are 10400 kg/hr at 2.9 bar and 8700 kg/hr at 0.6 par. The condenser pressure is 5 cm of Hg. Actual feed water temperature is 125 degrees * C . Find out the percentages of extracted steam at both points and thermal efficiency of the system. The power output From the plant is 25 MW
Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter47: High-pressure, Low-pressure, And Absorption Chilled-water Systems
Section: Chapter Questions
Problem 13RQ: The subcooling temperature in a condenser can be measured by taking the difference between the A....
Related questions
Question
![In a two stage regeneration system, steam
at 26 bar and 400 degrees * C is supplied at
a rate of 127*10^ 3 kg/hr The extractions are
10400 kg/hr at 2.9 bar and 8700 kg/hr at 0.6
bar. The condenser pressure is 5 cm of Hg.
Actual feed water temperature is 125
degrees * C . Find out the percentages of
extracted steam at both points and thermal
efficiency of the system. The power output
from the plant is 25 MW,](/v2/_next/image?url=https%3A%2F%2Fcontent.bartleby.com%2Fqna-images%2Fquestion%2Fc64eea47-2731-4a3b-a22c-eb2323829f1a%2F3ff39a23-2fe8-4c78-a41f-67998166f24d%2F798o66i_processed.jpeg&w=3840&q=75)
Transcribed Image Text:In a two stage regeneration system, steam
at 26 bar and 400 degrees * C is supplied at
a rate of 127*10^ 3 kg/hr The extractions are
10400 kg/hr at 2.9 bar and 8700 kg/hr at 0.6
bar. The condenser pressure is 5 cm of Hg.
Actual feed water temperature is 125
degrees * C . Find out the percentages of
extracted steam at both points and thermal
efficiency of the system. The power output
from the plant is 25 MW,
Expert Solution
![](/static/compass_v2/shared-icons/check-mark.png)
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 6 steps with 5 images
![Blurred answer](/static/compass_v2/solution-images/blurred-answer.jpg)
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
![Refrigeration and Air Conditioning Technology (Mi…](https://www.bartleby.com/isbn_cover_images/9781305578296/9781305578296_smallCoverImage.gif)
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning
![Refrigeration and Air Conditioning Technology (Mi…](https://www.bartleby.com/isbn_cover_images/9781305578296/9781305578296_smallCoverImage.gif)
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning