Oxygen analyzer is used to analyze the Oxygen content in the flue gas which is coming out from the Boiler's chimney. The O2 analyzer reading for boilers A, B, and C were 21 %, 17 %, 19 % by volume, respectively. Repeated measurements of oxygen percentages in the exhaust gas for the three boilers were performed. The results are shown in the following table: BOILER (A) BOILER (B) BOILER (C) 22.03 16.63 19.05 20.56 16.75 18.99 20.83 16.62 19.04 21.65 16.66 18.96 19.43 16.64 19.02 a) Determine the sample mean and standard deviations for the three samples b) Which of the samples do you think is more precise? Why? c) Which of the samples do you think is more accurate? Why?

Introduction to Chemical Engineering Thermodynamics
8th Edition
ISBN:9781259696527
Author:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Chapter1: Introduction
Section: Chapter Questions
Problem 1.1P
icon
Related questions
Question
100%
Note: use Excel spreadsheet for all your calculations and round to the
correct significant figure
Question 1
Oxygen analyzer is used to analyze the Oxygen content in the flue gas which is coming
out from the Boiler's chimney. The O2 analyzer reading for boilers A, B, and C were 21
%, 17 %, 19 % by volume, respectively. Repeated measurements of oxygen percentages
in the exhaust gas for the three boilers were performed. The results are shown in the
following table:
BOILER (A)
BOILER (B)
BOILER (C)
22.03
16.63
19.05
20.56
16.75
18.99
20.83
16.62
19.04
21.65
16.66
18.96
19.43
16.64
19.02
a) Determine the sample mean and standard deviations for the three samples
b) Which of the samples do you think is more precise? Why?
c) Which of the samples do you think is more accurate? Why?
Transcribed Image Text:Note: use Excel spreadsheet for all your calculations and round to the correct significant figure Question 1 Oxygen analyzer is used to analyze the Oxygen content in the flue gas which is coming out from the Boiler's chimney. The O2 analyzer reading for boilers A, B, and C were 21 %, 17 %, 19 % by volume, respectively. Repeated measurements of oxygen percentages in the exhaust gas for the three boilers were performed. The results are shown in the following table: BOILER (A) BOILER (B) BOILER (C) 22.03 16.63 19.05 20.56 16.75 18.99 20.83 16.62 19.04 21.65 16.66 18.96 19.43 16.64 19.02 a) Determine the sample mean and standard deviations for the three samples b) Which of the samples do you think is more precise? Why? c) Which of the samples do you think is more accurate? Why?
Expert Solution
steps

Step by step

Solved in 6 steps with 5 images

Blurred answer
Recommended textbooks for you
Introduction to Chemical Engineering Thermodynami…
Introduction to Chemical Engineering Thermodynami…
Chemical Engineering
ISBN:
9781259696527
Author:
J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:
McGraw-Hill Education
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemical Engineering
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY
Elements of Chemical Reaction Engineering (5th Ed…
Elements of Chemical Reaction Engineering (5th Ed…
Chemical Engineering
ISBN:
9780133887518
Author:
H. Scott Fogler
Publisher:
Prentice Hall
Process Dynamics and Control, 4e
Process Dynamics and Control, 4e
Chemical Engineering
ISBN:
9781119285915
Author:
Seborg
Publisher:
WILEY
Industrial Plastics: Theory and Applications
Industrial Plastics: Theory and Applications
Chemical Engineering
ISBN:
9781285061238
Author:
Lokensgard, Erik
Publisher:
Delmar Cengage Learning
Unit Operations of Chemical Engineering
Unit Operations of Chemical Engineering
Chemical Engineering
ISBN:
9780072848236
Author:
Warren McCabe, Julian C. Smith, Peter Harriott
Publisher:
McGraw-Hill Companies, The