*P5.81. Two loads, A and B, are connected in parallel across a 1-kV-rms 60-Hz line, as shown in Figure P5.81. Load A consumes 10 kW with a 90 percent lagging power factor. Load B has an apparent power of 15 kVA with an 80 percent lagging power factor. Find the power, reactive power, and apparent power delivered by the source. What is the pow are factor seen by the source? 1 kV rms 60 Hz Iline A contine es for wind over an Figure P5.81 B IB

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter14: Power Distribution
Section: Chapter Questions
Problem 14.11P
icon
Related questions
Question
*P5.81. Two loads, A and B, are connected in parallel
across a 1-kV-rms 60-Hz line, as shown in
Figure P5.81. Load A consumes
has an apparent power of 15 and
contine es tor: wind wer and
a 90 percent lagging power factor. Load B
an
Find the
1 kV rms
60 Hz
80 percent lagging power factor.
power, reactive power, and apparent power
delivered by the source. What is the power
factor seen by the source?
Iline
A
Figure P5.81
10 kW with
B
IB
Transcribed Image Text:*P5.81. Two loads, A and B, are connected in parallel across a 1-kV-rms 60-Hz line, as shown in Figure P5.81. Load A consumes has an apparent power of 15 and contine es tor: wind wer and a 90 percent lagging power factor. Load B an Find the 1 kV rms 60 Hz 80 percent lagging power factor. power, reactive power, and apparent power delivered by the source. What is the power factor seen by the source? Iline A Figure P5.81 10 kW with B IB
P5.83. Find the power, reactive power, and apparent
power delivered by the source in Figure P5.83.
Find the power factor and state whether it is
leading or lagging.
500 √2/0°
w = 377
50 Ω
0000
Figure P5.83
0.5 H
10 μF
Transcribed Image Text:P5.83. Find the power, reactive power, and apparent power delivered by the source in Figure P5.83. Find the power factor and state whether it is leading or lagging. 500 √2/0° w = 377 50 Ω 0000 Figure P5.83 0.5 H 10 μF
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 7 steps with 7 images

Blurred answer
Knowledge Booster
Analysis of Single Phase and Three Phase System
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning