PROBLEM 20:In a conventional refrigeration cycle which uses Freon-12 as the refrigerant, the temperature of the evaporating fluid is -20°C. It leaves the evaporator as saturated vapor at -20°C and enters the compressor. The pressure in the condenser is 1.30 MPa. The liquid leaves the condenser and enters the expansion valve at 40°C. It is proposed to modify this cycle by adding a heat exchanger that would superheat the suction vapor to 25°C. 2.1 Compare the coefficient of performance of these two cycles. 2.2 What is the temperature of the refrigerant entering the expansion valve with the heat exchanger? 2.3 For a load of 50 kW, determine the volume flow rate for both cycles.

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter22: Condensers
Section: Chapter Questions
Problem 7RQ: When a standard-efficiency air-cooled condenser is used, the condensing refrigerant will normally be...
icon
Related questions
Question

with PH and TS diagram

PROBLEM 2.0: In a conventional refrigeration cycle which uses Freon-12 as the refrigerant, the temperature
of the evaporating fluid is -20°C. It leaves the evaporator as saturated vapor at -20°C and enters the
compressor. The pressure in the condenser is 1.30 MPa. The liquid leaves the condenser and enters the
expansion valve at 40°C. It is proposed to modify this cycle by adding a heat exchanger that would superheat
the suction vapor to 25°C.
2.1 Compare the coefficient of performance of these two cycles.
2.2 What is the temperature of the refrigerant entering the expansion valve with the heat
exchanger?
2.3 For a load of 50 kW, determine the volume flow rate for both cycles.
Transcribed Image Text:PROBLEM 2.0: In a conventional refrigeration cycle which uses Freon-12 as the refrigerant, the temperature of the evaporating fluid is -20°C. It leaves the evaporator as saturated vapor at -20°C and enters the compressor. The pressure in the condenser is 1.30 MPa. The liquid leaves the condenser and enters the expansion valve at 40°C. It is proposed to modify this cycle by adding a heat exchanger that would superheat the suction vapor to 25°C. 2.1 Compare the coefficient of performance of these two cycles. 2.2 What is the temperature of the refrigerant entering the expansion valve with the heat exchanger? 2.3 For a load of 50 kW, determine the volume flow rate for both cycles.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Knowledge Booster
Work and Heat
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning