Problem 4: In the tension member connected to a gusset plate as shown below. Determine the value of b so that the net width along the rivets 1-2-3-4 is equal to the net width along 1-2-4. Then solve for the most critical net area. Use 30 mm diameter bolts and Table 510.3.3 for Nominal Hole Dimensions, mm. Gusset plate b - 100mm 400mm 100mm 100mm 12mm 150mm (Table 510.3.3) Nominal Hole Dimensions, mm Bolt Short-Slot Long-Slot Standard Oversize Diameter (Width x (Width x (Dia) (Dia) Length) Length) M16 18 20 18 x 22 18 x 40 M20 22 24 22 x 26 22 x 50 M22 24 28 24 x 30 24 x 55 M24 27(a) 30 27 x 32 27 x 60 M27 30 35 30 x 37 30 x 67 M30 33 38 33 x 40 33 x 75 ≥M36 d+3 d+8 (d+3) x (d+10) (d +3) x 2.5 d (a) Clearance provided allows the use of a M30 bolt if desirable. Z+ 60mm

Steel Design (Activate Learning with these NEW titles from Engineering!)
6th Edition
ISBN:9781337094740
Author:Segui, William T.
Publisher:Segui, William T.
Chapter3: Tension Members
Section: Chapter Questions
Problem 3.6.5P
icon
Related questions
Question
Problem 4: In the tension member connected to a gusset plate as shown below. Determine the value of b so
that the net width along the rivets 1-2-3-4 is equal to the net width along 1-2-4. Then solve for the most
critical net area. Use 30 mm diameter bolts and Table 510.3.3 for Nominal Hole Dimensions, mm.
Gusset plate
b
-
100mm
+
100mm
400mm
100mm
12mm
150mm
(Table 510.3.3) Nominal Hole Dimensions, mm
Bolt
Short-Slot
Long-Slot
Standard Oversize
Diameter
(Width x
(Width x
(Dia)
(Dia)
Length)
Length)
M16
18
20
18 x 22
18 x 40
M20
22
24
22 x 26
22 x 50
M22
24
28
24 x 30
24 x 55
M24
27(a)
30
27 x 32
27 x 60
M27
30
35
30 x 37
30 x 67
M30
33
38
33 x 40
33 x 75
≥M36
d+3
d+8
(d+3) x (d+10)
(d +3) x 2.5 d
(a) Clearance provided allows the use of a M30 bolt if desirable.
Z+
60mm
Transcribed Image Text:Problem 4: In the tension member connected to a gusset plate as shown below. Determine the value of b so that the net width along the rivets 1-2-3-4 is equal to the net width along 1-2-4. Then solve for the most critical net area. Use 30 mm diameter bolts and Table 510.3.3 for Nominal Hole Dimensions, mm. Gusset plate b - 100mm + 100mm 400mm 100mm 12mm 150mm (Table 510.3.3) Nominal Hole Dimensions, mm Bolt Short-Slot Long-Slot Standard Oversize Diameter (Width x (Width x (Dia) (Dia) Length) Length) M16 18 20 18 x 22 18 x 40 M20 22 24 22 x 26 22 x 50 M22 24 28 24 x 30 24 x 55 M24 27(a) 30 27 x 32 27 x 60 M27 30 35 30 x 37 30 x 67 M30 33 38 33 x 40 33 x 75 ≥M36 d+3 d+8 (d+3) x (d+10) (d +3) x 2.5 d (a) Clearance provided allows the use of a M30 bolt if desirable. Z+ 60mm
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Tension members
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Steel Design (Activate Learning with these NEW ti…
Steel Design (Activate Learning with these NEW ti…
Civil Engineering
ISBN:
9781337094740
Author:
Segui, William T.
Publisher:
Cengage Learning