Properties of Carbon Dioxide: h @ 220 KPa and -5°C = 350 KJ/kg h: @ 25°C = 223.65 KJ/kg h @ 22°C = 220.75 KJ/kg h. @ 220 KPa = 347.13 KJ/kg %3D Saturated Vapor Carbon Dioxide refrigerant at 220 KPa leaves the evaporator and enters the compressor at -5 °C. The refrigerant leaves the condenser as saturate liquid at 25 °C and enters the expansion valve at 22 °C. Heat rejected from the condenser amount 90 KW. The work to the compressor is 60 KJ/kg while the heat lost from the compressor is 5 KJ/kg. If 2.5 KJ/kg of heat are lost in the piping between the compressor and condenser. Solve for QA in KW.

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter45: Domestic Refrigerators And Freezers
Section: Chapter Questions
Problem 20RQ: Welded ______sealed compressors are normally used in household refrigerators.
icon
Related questions
Question
Properties of Carbon Dioxide:
h @ 220 KPa and -5°C = 350 KJ/kg
hi @ 25°C = 223.65 KJ/kg
h: @ 22°C = 220.75 KJ/kg
ha @ 220 KPa = 347.13 KJ/kg
%3D
Saturated Vapor Carbon Dioxide refrigerant at 220 KPa leaves the evaporator and
enters the compressor at -5 °C. The refrigerant leaves the condenser as saturate liquid
at 25 °C and enters the expansion valve at 22 °C. Heat rejected from the condenser
amount 90 KW. The work to the compressor is 60 KJ/kg while the heat lost from the
compressor is 5 KJ/kg. If 2.5 KJ/kg of heat are lost in the piping between the
compressor and condenser.
Solve for QA in KW.
Transcribed Image Text:Properties of Carbon Dioxide: h @ 220 KPa and -5°C = 350 KJ/kg hi @ 25°C = 223.65 KJ/kg h: @ 22°C = 220.75 KJ/kg ha @ 220 KPa = 347.13 KJ/kg %3D Saturated Vapor Carbon Dioxide refrigerant at 220 KPa leaves the evaporator and enters the compressor at -5 °C. The refrigerant leaves the condenser as saturate liquid at 25 °C and enters the expansion valve at 22 °C. Heat rejected from the condenser amount 90 KW. The work to the compressor is 60 KJ/kg while the heat lost from the compressor is 5 KJ/kg. If 2.5 KJ/kg of heat are lost in the piping between the compressor and condenser. Solve for QA in KW.
Expert Solution
steps

Step by step

Solved in 3 steps with 3 images

Blurred answer
Knowledge Booster
Refrigeration and Air Conditioning
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning